DS1844S-100+ Maxim Integrated Products, DS1844S-100+ Datasheet

no-image

DS1844S-100+

Manufacturer Part Number
DS1844S-100+
Description
IC POT DIG QUAD 100K 20-SOIC
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1844S-100+

Taps
64
Resistance (ohms)
100K
Number Of Circuits
4
Temperature Coefficient
750 ppm/°C Typical
Memory Type
Volatile
Interface
2-Wire or 5-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-SOIC (7.5mm Width)
Resistance In Ohms
100K
Number Of Pots
Quad
Taps Per Pot
64
Resistance
100 KOhms
Wiper Memory
Volatile
Digital Interface
Serial (2-Wire, 5-Wire)
Operating Supply Voltage
3.3 V, 5 V
Supply Current
2.5 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
FEATURES
§ Four independent, digitally controlled 64-
§ Two interface control options
§ Standard resistance values
§ Mixed resistor value combinations (contact
§ Operating Temperature Range
DESCRIPTION
The DS1844 Quad Digital Potentiometer is a four-channel, digitally controlled linear potentiometer. Each
potentiometer is comprised of 63 equi-resistive sections and has three terminals accessible to the user.
These include the high side terminals, H
wiper position on the resistor ladder is selected via an 8-bit register value. Communication and control of
the device are supported by two types of serial interface. These include a 5-wire I/O shift register
interface and a 2-wire addressable interface.
www.maxim-ic.com
position potentiometers
-
-
-
-
-
factory for availability)
- Industrial: -40°C to +85°C
5-wire serial
2-wire addressable
DS1844-010 10 kW
DS1844-050 50 kW
DS1844-100 100 kW
X
, the wiper terminals, W
1 of 14
R/W, A0
A2, RST
PIN ASSIGNMENT
PIN DESCRIPTION
V
PS
A0, A1, A2 - Device Select Pins (2-Wire)
SDA
SCL
R/
D
CLK
D
H
L
W
GND
RST
0
Quad Digital Potentiometer
GND
CC
IN
OUT
0
-L
0
-H
W
-W
W3
W2
PS
H2
H3
L3
L2
Device Description
3
3
20-Pin TSSOP (173-mil)
3
20-Pin SOIC (300-mil)
20-Pin DIP (300-mil)
X
1
2
3
4
5
6
7
8
9
10
, and the low-side terminals, L
- 2.7V to 5.5V
- Port Select
- Serial Data I/O (2-Wire)
- Serial Clock (2-Wire)
- Read/Write enable (5-Wire)
- Serial Port Reset Input (5-Wire)
- Serial Port Data Input (5-Wire)
- Serial Port Clock Input (5-Wire)
- Cascade Data Output (5-Wire)
- High-end Terminal of Pot
- Low-end Terminal of Pot
- Wiper Terminal of Pot
- Ground
20
19
18
17
16
15
14
13
12
11
V
H1
H0
W0
L0
L1
W1
SCL, CLK
SDA, D
A1, D
CC
OUT
DS1844
IN
053105
X.
The

Related parts for DS1844S-100+

DS1844S-100+ Summary of contents

Page 1

FEATURES § Four independent, digitally controlled 64- position potentiometers § Two interface control options - 5-wire serial - 2-wire addressable § Standard resistance values - DS1844-010 DS1844-050 DS1844-100 100 kW § Mixed resistor ...

Page 2

The DS1844 is available in standard 10 kW, 50 kW, and 100 kW versions. Mixed resistor combinations are also available through custom setups. The DS1844 is specified to operate over the industrial temperature range: -40°C to +85°C. Packages for the ...

Page 3

When writing data, the R/ input should low state. Once W latched (or valid) on the low-to-high transition of the CLK signal. Once, eight low-to-high transitions have occurred on the CLK input, the associated 8-bit data block ...

Page 4

Data valid: The state of the data line represents valid data when, after a START condition, the data line is stable for the duration of the HIGH period of the clock signal. The data on the line can be changed ...

Page 5

SLAVE ADDRESS A command/control byte is the 1 The command/control byte consists of a 4-bit control code. For the DS1844, this is set as 0101 binary for read/write operations. The next 3 bits of the command/ control byte are the ...

Page 6

DS1844. Once the command/control byte has been issued and the master receives the acknowledgment from the DS1844, potentiometer wiper data is transmitted to the DS1844 by the master device the case of the 5-wire ...

Page 7

ABSOLUTE MAXIMUM RATINGS* Voltage on Any Pin Relative to Ground Operating Temperature Storage Temperature Soldering Temperature * This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the ...

Page 8

ANALOG RESISTOR CHARACTERISTICS (-40°C to +85°C; V PARAMETER SYMBOL End-to-End Resistor Tolerance Absolute Linearity Relative Linearity -3dB Cutoff frequency Temperature Coefficent 2-WIRE ADDRESSABLE INTERFACE AC ELECTRICAL CHARACTERISTICS PARAMETER SYMBOL Port Select Setup SCL Clock Frequency Bus Free Time Between STOP ...

Page 9

SERIAL INTERFACE AC ELECTRICAL CHARACTERISTICS PARAMETER Port Select Setup R/ W Setup Clock Frequency Width of CLK Pulse Data Setup Time Data Hold Time Progapation Delay Time High to Low Level Clock to Output RST High to Clock Input ...

Page 10

Address Inputs, A0, A1, and A2, should be tied to either V address selections. 12. Resistor inputs cannot go below GND by more than 0.5 volts or above V volts. 13. -3dB cutoff frequency characteristics for the DS1844 depend ...

Page 11

DS1844 BLOCK DIAGRAM Figure 1 WIPER REGISTER CONFIGURATION Figure ...

Page 12

SERIAL TIMING DIAGRAM Figure 3 (A), (B) (A) WRITING DATA TO THE DS1844 ...

Page 13

DATA TRANSFER OVERVIEW Figure 4 START COMMAND/CONTROL BYTE Figure 5 2-WIRE READ PROTOCOL Figure 6 2-WIRE WRITE PROTOCOLS Figure ...

Page 14

TIMING DIAGRAM Figure 8 DIGITAL OUTPUT LOAD Figure ...

Related keywords