9-1462036-1 TE Connectivity, 9-1462036-1 Datasheet - Page 2

no-image

9-1462036-1

Manufacturer Part Number
9-1462036-1
Description
D3527W=FU RELAY 240MW 24 V
Manufacturer
TE Connectivity
Series
FU2, AXICOMr
Datasheets

Specifications of 9-1462036-1

Rohs Compliant
YES
Relay Type
Telecom
Contact Form
DPDT (2 Form C)
Contact Rating (current)
2A
Switching Voltage
250VAC, 220VDC - Max
Coil Type
Non Latching
Coil Current
10mA
Coil Voltage
24VDC
Turn On Voltage (max)
18 VDC
Turn Off Voltage (min)
2.4 VDC
Features
-
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Material
Palladium (Pd), Ruthenium (Ru), Gold (Au)
Operate Time
5ms
Release Time
5ms
Coil Power
240 mW
Coil Resistance
2.4K Ohms
Operating Temperature
-55°C ~ 85°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
2
U
U
U
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
Terminal assignment
TOP view on component side of PCB
Coil Data
Coil versions, monostable
High dielectric Australia version, monostable
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
PCB layout
TOP view on component side of PCB
Coil
code
71
73
76
max
op min
rel min
upper limit of the operative range of the coil voltage (limiting voltage) when coils are
continuously energized
lower limit of the operative range of the coil voltage (reliable operate voltage)
lower limit of the operative range of the coil voltage (reliable release voltage)
THT version
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Coil Operating Range
voltage
2.6
2.4
2.2
1.8
1.6
1.4
1.2
Rated
0.8
0.6
0.4
0.2
VDC
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
2
(continued)
1
0
12
-60 -50 -40 -30 -20 -10 0
3
5
-60 -50 -40 -30 -20 -10
U
U
nom.
nom.
nominal coil voltage
nominal coil voltage
Operate
voltage
VDC
2.25
3.75
9.00
Ambient Temperature [°C]
Ambient Temperature [°C]
0
10 20 30 40 50 60 70 80 90 10
10 20 30 40 50 60 70 80 90 100 110 120 130 140
Limiting
voltage
22.10
VDC
5.50
9.20
Signal Relays
FT2/FU2 Relay
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Release
voltage
VDC
0.30
0.50
1.20
U
U
U
U
U
max.
max.
max.
op. min.
rel. min.
resistance
0
U
U
200 mW coil
240 mW coil
U
Ω±10%
max.
max.
max.
at 0 A
at 2 x 1 A
at 2 x 2 A
300 mW coil
11
0
480
Coil
30
83
at 0 A
at 2 x 1 A
at 2 x 2 A
12
(Continued)
0
U
U
SMT, long terminals
13
op. min.
rel. min.
0
14
0
Rated coil
power
mW
300
300
300
U
Umax. =
Uop. min. =
Urel. min. =
nom
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
Insulation
Initial dielectric strength
Initial surge withstand voltage
Initial insulation resistance
Capacitance
Cross talk at 100MHz/900MHz
Insertion loss at 100MHz/900MHz
Voltage standing wave ratio (VSWR)
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
Ambient temperature
Thermal resistance
Category of environmental protection
Degree of protection, IEC 60529
Vibration resistance (functional)
Shock resistance (functional), half sinus 11ms
Shock resistance (destructive), half sinus 0.5ms
Weight
Resistance to soldering heat THT
Resistance to soldering heat SMT
Moisture sensitive level, JEDEC J-Std-020D
Ultrasonic cleaning
Packaging/unit
= Nominal coil voltage
between open contacts
between contact and coil
between adjacent contacts
between open contacts
between contact and coil
between adjacent contacts
between insulated elements
between open contacts
between contact and coil
between adjacent contacts
at 100MHz/900MHz
IEC 61810
IEC 60068-2-20
IEC 60068-2-58
THT version
SMT short terminals
SMT long terminals
www.tycoelectronics.com/customersupport/rohssupportcenter
Upper limit of the operative range of the
coil voltage (limiting voltage) when coils
are continously energized
Lower limit of the operative range of the
coil voltage (reliable operate voltage)
Lower limit of the operative range of
the coil voltage (reliable release voltage)
refer to the Product Compliance Support Center at
SMT, short terminals
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
standard
tube/50 pcs., box/2000 pcs.
reel/500 pcs.,box/2500 pcs.
reel/400 pcs.,box/2000 pcs.
1000V
1500V
1500V
RT III - immersion cleanable
IP 67, immersion cleanable
1500V
2500V
1500V
>10
not recommended
9
10g, 10 to 500Hz
-30.6dB/-13.7dB
-0.02dB/-0.50dB
-55°C to +85°C
rms
rms
rms
1.02 / 1.27
265°C/10s
265°C/10s
max. 4pF
max. 1pF
max. 1pF
<125K/W
5 of 13
max. 3g
MSL3
500g
15g
high dielectric
1500V
4000V
1800V
>10
2500V
6000V
2500V
Axicom
9
rms
rms
rms

Related parts for 9-1462036-1