FUSE, PTC RESET, 30V, 900mA, RADIAL

RUEF090

Manufacturer Part Number
RUEF090
Description
FUSE, PTC RESET, 30V, 900mA, RADIAL
Manufacturer
TE Connectivity
Series
RUEFr
Datasheets

Specifications of RUEF090

Holding Current
900mA
Tripping Current
1.8A
Initial Resistance Max
0.12ohm
Operating Voltage
30V
Ptc Fuse Case
Radial Leaded
Initial Resistance Min
0.07ohm
Resistance R1
0.22ohm
Rohs Compliant
Yes
Hold Current
900mA
Trip Current
1.8A
Initial Resistance (min)
70mOhm
Initial Resistance (max)
120mOhm
Voltage Rating Max
30V
Trip Time (max)
5.9@4.5As
Power Dissipation (typ)
0.6W
Post Trip Resistance (max)
220mOhm
Agency Approvals
CSA/TUV/UL
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
85C
Brand/series
PolySwitch®/RUEF Series
Current, Rating
0.9 A
Dimensions
0.29x0.12x0.48 "
Material, Body
Epoxy Polymer
Mounting Type
PCB
Primary Type
Resettable
Resistance, Dc
0.12 Ohms
Termination
Radial
Voltage, Rating
30 VAC/VDC
Agency Recognition
UL, CSA, TUV
Ul File Number
E74889
Csa File Number
A78165
Vmax (v)
30
Imax (a)
100
Ih (room Temperature) (a)
0.9
It (room Temperature) (a)
1.80
Rmin (?)
0.07
Rmax (?)
0.120
R1 Max [post Trip] (?)
0.22
Power Dissipation (typical) (w)
0.60
Construction
Radial
Lead Type
Standard Kinked Lead
Family Name
RUEF
Coating
Coated
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C
Rohs/elv Compliance History
Always was RoHS compliant
Tuv Certificate No.
Available on request (per IEC 60730-1)
Operating Temperature (max.) (°c)
85
Application
Radial
Packaging Method
Bulk
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RUEF090
Manufacturer:
RYC
Quantity:
13 678
Part Number:
RUEF090
Manufacturer:
RAYCHEM
Quantity:
1 884
WARNING:
Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame.
The devices are intended for protection against occasional overcurrent or overtemperature fault conditions and should not be
used when repeated fault conditions or prolonged trip events are anticipated.
Contamination of the PPTC material with certain silicon based oils or some aggressive solvents can adversely impact the
performance of the devices.
Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic,
thermal, and mechanical procedures for electronic components.
Operation in circuit with a large inductance can generate a circuit voltage (L
/
) above the rated voltage of the
di
dt
PolySwitch resettable device.
13
1 36

Related parts for RUEF090