E2A-S08LN04-WP-C1 2M Omron, E2A-S08LN04-WP-C1 2M Datasheet - Page 15

Proximity Sensors M8 LNG SHLD SS 4mm N PN NO 2M

E2A-S08LN04-WP-C1 2M

Manufacturer Part Number
E2A-S08LN04-WP-C1 2M
Description
Proximity Sensors M8 LNG SHLD SS 4mm N PN NO 2M
Manufacturer
Omron
Series
E2Ar
Type
Cylindrical Proximity Sensorr
Datasheet

Specifications of E2A-S08LN04-WP-C1 2M

Output Type
NPN
Proximity Sensor Sensing Distance
4mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-40C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
32V
Pin Count
3
Maximum Operating Temperature
+ 70 C
Supply Voltage
12 VDC to 24 VDC
Supply Current
10 mA
Output Voltage
2 V
Operating Supply Voltage
10 VDC to 32 VDC
Mounting Style
Screw
Sensing Distance
4 mm
Minimum Operating Temperature
- 40 C
Barrel Size
M8
Current Rating
200 mA
Features
Reduces cost and frequency of proximity sensor
Voltage Rating
32 VDC
Lead Free Status / Rohs Status
Compliant
Wiring
High-tension Lines
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to pre-
vent against Proximity Sensor damage or malfunctioning.
Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
Mounting
The Proximity Sensor must not be subjected to excessive shock with
a hammer when it is installed, otherwise the Proximity Sensor may
be damaged or lose its water-resistivity.
Do not tighten the nut with excessive force. A washer must be used
with the nut.
M8
M12
M18
M30
Stainless steel type 9 N·m
Brass type
Type
4 N·m
30 N·m
70 N·m
180 N·m
Torque
Maintenance and Inspection
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
1. Check for mounting position, dislocation, looseness, or distortion
2. Check for loose wiring and connections, improper contacts, and
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environ-
5. Check for proper lighting of indicators (for models with a set indi-
Never disassemble or repair the Sensor.
Environment
Water Resistivity
Do not use the Proximity Sensor underwater, outdoors, or in the rain.
Operating Environment
Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors so
that its reliability and life expectancy can be maintained. Although
the Proximity Sensor is water resistive, a cover to protect the Prox-
imity Sensor from water or water-soluble machining oil is recom-
mended so that its reliability and life expectancy can be maintained.
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
of the Proximity Sensor and sensing objects.
line breakage.
mental conditions.
cator.)