E4R-A Omron, E4R-A Datasheet
E4R-A
Specifications of E4R-A
Related parts for E4R-A
E4R-A Summary of contents
Page 1
... Hz, 1.5-mm double amplitude for 2 hours each and Z axes 2 100 m/s (approx times each and Z axes (This table continues on the next page.) E4R Part number E4R-A E4R-2 E4R-SP S82K-00312 Part number 14PFA 8PFA ...
Page 2
... E4R Specifications Table - - continued from previous page Part number E4R-A Cable length Use shielded cable (65.62 ft) max. between sensor and controller Weight Approx. 400 g Material Plastic Temperature influence ±5% max. of sensing distance within the temperature range 10°C to 40°C (14°F to 104°F) Voltage influence ± ...
Page 3
... E4R Dimensions Unit: mm (inch) J E4R-A SENSOR J E4R-2 CONTROLLER Note: The dimensions are external dimensions that include the 14PFA Surface-mounting Socket. The 14PFA Surface-mounting Socket is provided with the E4R-2. J E4R-SP REFERENCE PULSE UNIT Note: The 8PFA Surface-mounting Socket is provided with the E4R-SP. ...
Page 4
... Use shielded cables for the oscillator’s transmission line (connected to the OSC terminals) and the reception line E4R-A (connected to the REC terminals). Each cable must be a maximum length. The shielded cables connecting the Sensor and terminals 7, 14, Sensor 1 and 6 (or 5, 12, and 4) must be all parallel conductors with 11 strands of 0 ...
Page 5
... Note: 1. Sensors 1 and 2 are in OR operation. 2. Set the slide switch of the E4R-2 to OPEN. OMRON ON- -LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci Specifications subject to change without notice. E4R E4R-A Sensor 1 Sensor 2 OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A. ...