M28W640HCT70N6E NUMONYX, M28W640HCT70N6E Datasheet - Page 27

no-image

M28W640HCT70N6E

Manufacturer Part Number
M28W640HCT70N6E
Description
TSOP-1 48 12X20 CUSTD FLASH
Manufacturer
NUMONYX
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M28W640HCT70N6E
Manufacturer:
JRC
Quantity:
9 100
M28W640HCT, M28W640HCB
Table 10.
1. The lock status is defined by the write protect pin and by DQ1 (‘1’ for a locked-down block) and DQ0 (‘1’ for
2. All blocks are locked at power-up, so the default configuration is 001 or 101 according to WP status.
3. A WP transition to V
Current state
Current Protection status
a locked block) as read in the Read Electronic Signature command with A1 = V
1,0,1
0,0,1
1,0,0
1,1,0
1,1,1
0,0,0
0,1,1
(WP, DQ1, DQ0)
(2)
(2)
Protection status
Program/Erase
allowed
IH
yes
yes
yes
on a locked block will restore the previous DQ0 value, giving a 111 or 110.
no
no
no
no
(1)
After Block
command
Lock
1,0,1
1,0,1
1,1,1
1,1,1
0,0,1
0,0,1
0,1,1
After Block
command
Unlock
Next Protection status
1,0,0
1,0,0
1,1,0
1,1,0
0,0,0
0,0,0
0,1,1
(WP, DQ1, DQ0)
After Block
Lock-down
command
1,1,1
1,1,1
1,1,1
1,1,1
0,1,1
0,1,1
0,1,1
IH
and A0 = V
(1)
1,1,1 or 1,1,0
Block locking
IL
transition
.
After WP
0,0,0
0,0,1
0,1,1
0,1,1
1,0,0
1,0,1
27/72
(3)