3. Calculation of coil temperature rise when R initial and R final are known:
Delta T = (234.5 + T
Delta T = Temperature rise (°C)
T
R
R
R
Temperature can also be found by making the R
coefficient of correction graph in Fig. 2, and then finding the corresponding temperature.
EXAMPLE:
Catalog indicates coil resistance of 290 ohm at 25°C. What is the value at 125°C?
From the chart: 290 x 1.39 = 403.31 Ohms.
Date of issue: 6/00
1
1
2
2
= Initial temperature (°C)
= Initial resistance (Ohms)
= Final resistance (Ohms)
= K
2
R
1
1
) (R
2
/R
TEMPERATURE CORRECTION CHART FOR RESISTANCE
1
- 1)
2
/R
1
ratio = the
Fig. 2