M83536/9-023M

Manufacturer Part NumberM83536/9-023M
DescriptionElectromechanical Relay DPDT 12A 28VDC 320Ohm Socket
ManufacturerLeach International
M83536/9-023M datasheet
 


1
Page 1
2
Page 2
3
Page 3
4
Page 4
5
Page 5
6
Page 6
7
Page 7
8
Page 8
9
Page 9
10
Page 10
Page 1/10

Download datasheet (869Kb)Embed
Next
ENGINEERING DATA SHEET
APPLICATION NOTES:
023
APPLICABLE SOCKET:
SO-1049-8309/8987
SO-SSL
CONTACT ELECTRICAL CHARACTERISTICS
Contact rating
per pole and load
@28 Vdc
type [1]
Resistive
12
Inductive [3]
8
Motor
4
Lamp
2
Overload
40
Rupture
50
©
Featuring
LEACH
power and control solutions
www.esterline.com
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 07/10
All welded construction
Contact arrangement
Qualified at 10 Amps to
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions of case
Special models available upon request.
Hermetically sealed, corrosion resistant metal can.
Contact factory for information on MIL-qualified part numbers.
Load current in Amps
@115 Vac
@115/200 Vac, 400 Hz, 3Ø
400 Hz
12
12
8
8
4
4
2
2
60
60
80
80
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
- 121 -
SERIES J
RELAY - NONLATCH
2 PDT, 12 AMPS
2 PDT
MIL-PRF-83536
28 Vdc; 115 Vac, 400 Hz, 1
phase and 115/200 Vac, 400
Hz, 3 phases
0.088lb max
1.01in x .51in x 1.00in
@115/200 Vac, 60 Hz, 3Ø
[2]
2.5
2.5
2
-
N/A
N/A
EUROPE
ASIA
2 Rue Goethe
Units 602-603 6/F Lakeside 1
57430 Sarralbe
No.8 Science Park West Avenue
France
Phase Two, Hong Kong Science Park
.
Pak Shek Kok, Tai Po, N.T.
.
Hong Kong
Tel: (33) 3 87 97 31 01
Tel: (852) 2 191 3830
Fax: (33) 3 87 97 96 86
Fax: (852) 2 389 5803
Page 1 of 4

M83536/9-023M Summary of contents

  • Page 1

    ENGINEERING DATA SHEET APPLICATION NOTES: 023 APPLICABLE SOCKET: SO-1049-8309/8987 SO-SSL CONTACT ELECTRICAL CHARACTERISTICS Contact rating per pole and load @28 Vdc type [1] Resistive 12 Inductive [3] 8 Motor 4 Lamp 2 Overload 40 Rupture 50 © Featuring LEACH power ...

  • Page 2

    COIL CHARACTERISTICS (Vdc) CODE Nominal operating voltage Maximum operating voltage Maximum pickup voltage - Cold coil at +125° During high temp test at +125° During continuous current test at +125° C Maximum drop-out voltage Coil resistance ...

  • Page 3

    NOTES [1] Standard Intermediate current test applicable. [ load life, 10,000 cycles. [3] Inductive load life, 20,000 cycles. [4] "N" R & V coils have back EMF suppression to 42 volts maximum. [5] 500 Vrms with silicone gasket ...

  • Page 4

    TERMINAL TYPES Standard Tolerance: ± .010 1. Insulator P/N RC-RP800060-5 or RC-RP920060-1 available from Cornucopia Plastics, Paso Robles, CA. STANDARD TOL: ±.010 Date of issue: 07/10 - 124 - SERIES J Page ...

  • Page 5

    ... Or when mounted in the same direction, separate each relay from the other by 1/8 inch (figure “B”). If two or more rows of relays are installed, allow clearance of 1/8 inch between rows, (figures “C” and “D”). Provide 3/16-inch space between relays if used in opposition (figure “E”). ...

  • Page 6

    ENGINEERING DATA SHEET GENERAL CHARACTERISTICS 1. Supplied with mounting hardware and No. 16 contacts, No. 16 crimp (see socket drawing illustration SO-1049-8309); No. 16 contacts, No. 20 crimp for SO-1049-8987 (not illustrated) 2. Standard tolerances 3. Weight 4. Temperature range ...

  • Page 7

    ... SNAP AND LOCK SOCKET SERIES DESIGNATION SERIES J, JA, K, KA, KL, TDX MEETS THE REQUIREMENTS OF: 2 POLE 2-pole, 10A relays MIL-PRF-12883/41 M83536, M83726 and MS27709 Mates with 4-pole, 10A relays MIL-PRF-12883/40 M83536 Mates with FEATURES Low profile Bottom panel mount Snaps into panel ...

  • Page 8

    SOCKET DIMENSIONS RELAY GASKET SUPPLIED WITH RELAY .20 TERMINAL LAYOUT SO-SSL-JA-2 Date of issue: 3/06 MTG SCREW PHILLIPS HEAD WASHER SPACER PANEL .064±.005 THICK SOCKET RECOMMENDED MOUNTING PANEL CUTOUT WIRE SEALING GROMMET .20 .520 MAX .10 1.40 SO-SSL-JA ...

  • Page 9

    SOCKET DIMENSIONS GASKET SUPPLIED WITH RELAY .200 TYP .62 TERMINAL LAYOUT SO-SSL-K-1 SO-SSL-KL-1 Date of issue: 3/06 RELAY MTG SCREW PHILLIPS HEAD WASHER SPACER .62 PANEL .064±.005 THICK SOCKET WIRE SEALING GROMMET RECOMMENDED MOUNTING PANEL CUTOUT .10 .200 TYP 1.000 ...

  • Page 10

    SOCKET NUMBERING SYSTEM 1-Basic socket designation________________________| 2-Body style (short snap lock)________________________| 3-Mating relay (J, JA, K, KA, KL, TDX)____________________| 4-Polarization (see terminal layout)__________________________||| 5-Hardware (0=less hardware, 1=with hardware)__________________|| 6-Contacts (0=less contacts, 1=with contacts)___________________| Date of issue: 3/06 SO SSL KA ...