C091 31C008 100 2 Amphenol, C091 31C008 100 2 Datasheet - Page 5

Circular DIN Connectors Plug 8 Pin Rear MT solder

C091 31C008 100 2

Manufacturer Part Number
C091 31C008 100 2
Description
Circular DIN Connectors Plug 8 Pin Rear MT solder
Manufacturer
Amphenol
Datasheet

Specifications of C091 31C008 100 2

Standard
DIN
Product Type
Connectors
Contact Style
Pin (Male)
Number Of Contacts
8
Termination Style
Solder
Shell Plating
Nickel
Contact Plating
Silver
Current Rating
5 A
Voltage Rating
250 V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
100 2 31C008 C091 U
Degree of protection
Electrical devices to which connectors belong have to be protected for safety reasons from outside influences like dust, foreign objects, direct contact, moisture
and water. This protection is provided on industrial connectors by their housings with their latching devices and sealed cable entries.
The degree of protection can be selected depending on the type of intended use. The standard IEC 60529 and/or DIN EN 60529 has specified the degree of
protection and divided into several classes.
The degree of protection is indicated in the following way:
Code letters
(Ingress Protection)
1st charact. numeral (degree of protection against access
to hazardous parts and against solid foreign objects)
2nd charact. numeral (degree of protection against ingress of water)
The following charts give an overview about all protection degrees.
Amphenol
1st charact. Brief description
numeral
0
1
2
3
4
5
6
C 091
IP Codes
(Ingress Protection)
Non-protected
Protected against access to
hazardous parts with the
back of a hand. Protected
against solid foreign objects
of ≥50mm
Protected against access to
hazardous parts with a
finger.
Protected against solid
foreign objects of
≥12.5mm Ø.
Protected against access
to hazardous parts with a
tool. Protected against solid
foreign objects of ≥2.5mm
Ø.
Protected against access to
hazardous parts with a
wire.Protected against solid
foreign objects of ≥1mm Ø.
Protected against access to
hazardous parts with a wire.
Dust-protected.
Protected against access to
hazardous parts with a wire.
Dust-tight.
IP 65
Ø.
Definition
The probe, sphere of 50mm
Ø, shall not fully penetrate
and shall have adequate
clearance from hazardous
parts.
The jointed test finger of
12mm Ø, 80mm length,
shall have adequate clearance
from hazardous parts. The
probe, sphere of 12.5mm Ø,
shall not fully penetrate.
The probe of 2.5mm Ø shall
not penetrate at all.
The probe of 1mm Ø shall
not penetrate at all.
The probe of 1mm Ø shall
not penetrate.
Intrusion of dust is not
totally prevented, but dust
shall not penetrate in a
quantity to interfere with
satisfactory operation of
the device or to impair
safety.
The probe of 1mm Ø shall
not penetrate.
No intrussion of dust.
1) Remark: Numeral acc. to DIN 40050 part 9, vehicles IP code
2nd charact. Brief description
numeral
0
1
2
3
4
5
6
7
8
9 K
1)
Non-protected
Protected against vertically
falling water drops
Protected against vertically
falling water drops when
enclosure tilted up to 15°
Protected against spraying
water
Protected against splashing
water
Protected against water jets
Protected against powerful
water jets
Protected against the effects
of temporary immersion in
water
Protected against the effects
of continous immersion in
water
Protected against water
during high pressure/steam
jet cleaning
Definition
Vertically falling drops shall
have no harmful effects.
Vertically falling drops shall
have no harmful effects when
the enclosure is tilted at any
angle up to 15° on either side
of the vertical.
Water sprayed at an angle up
to 60° on either side of the
vertical shall have no harmful
effects.
Water splashed against the
enclosure from any direction
shall have no harmful effects.
Water projected in jets against
the enclosure from any
direction shall have no harmful
effects.
Water projected in powerful
jets against the enclosure
from any direction shall have
no harmful effects.
Intrusion of water in quantities
causing harmful effects shall
not be possible when the
enclosure is temporally
immersed in water for 30 min.
in 1m depth.
Intrusion of water in quantities
causing harmful effects shall
not be possible when the
enclosure is continuously
immersed in water under
conditions which shall be
agreed between manufacturer
and user but which are more
severe than for numeral 7.
Water projected in powerful
jets with high pressure against
the enclosure from any
direction shall have no harmful
effects.
5

Related parts for C091 31C008 100 2