88-563667-10S Amphenol, 88-563667-10S Datasheet

no-image

88-563667-10S

Manufacturer Part Number
88-563667-10S
Description
Circular MIL / Spec Connectors 97 Series MIL-DTL-22992
Manufacturer
Amphenol
Datasheet

Specifications of 88-563667-10S

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
®
Amphenol Heavy Duty
Cylindrical Connectors
12-052-9
Amphenol

Related parts for 88-563667-10S

88-563667-10S Summary of contents

Page 1

... Amphenol Heavy Duty Cylindrical Connectors 12-052-9 Amphenol ...

Page 2

Inside Cover is Blank ...

Page 3

... Accessories - Encapsulation Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Accessories - Encapsulation End Bell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 MS Solder Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Solderless Crimp Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Application Tools (Crimp Type Heavy Duty Cylindrical Connectors Proprietary, QWL Series General Information, Design Features, (References Amphenol Catalog 12-053 Sales Office Listing Amphenol Aerospace is a Certified ISO 9001 Manufacturer Page ...

Page 4

... Delaware Avenue Sidney, New York 13838-1395 Telephone: 607-563-5011 Fax: 607-563-5157 This catalog and other product literature from Amphenol Aerospace and Amphenol Industrial Operations can be viewed, saved, and down-loaded from our website: www.amphenol-aerospace.com. Due to space limitations, metric equivalents of dimensional data in this catalog have not been included. All dimensions given may be converted to the metric system by the standard formula ...

Page 5

... High Current Capacity • Rugged Construction • Safety • Serviceability Amphenol meets the demands for heavy duty connectors by providing three cylindrical connector series, each with unique design characteristics for reliable operation in specific indus- trial environments. Class “L” – for the heaviest electrical loads (Pages 2 – 19) • ...

Page 6

... Serviceable Contacts - contacts are normally crimped to the cable before connector assem- bly. No insertion tools required. Bushings are available to adapt smaller diameter wires to larger contacts * Amphenol design is covered by one or more of the following U. S. Patent Numbers: 3,023,396; 3,221,292. 2 Class L* heavy ® ...

Page 7

... Accessories - supplied with all Class L connectors as indicated on the individual connector descriptions. Contact Size Replacement accessories may be ordered separately. 6 See pages 12 through 15. 4 1/0 4/0 † MIL-C-22992 includes shell size 48, rated at 150 amperes. Consult your local Amphenol sales representative or Amphenol, Sidney, NY for availability. 3 ...

Page 8

... MASTER KEY/KEYWAY POSITION MASTER KEYWAY TYPICAL SOCKET front face of receptacle shown ARRANGEMENT Note that insert arrangement does not rotate with master key/keyway Amphenol Federal Vendor Identification FSCM77820 DC 2 Wire 28 VDC N (105°) N (105°) N (105°) N (105° ...

Page 9

MIL-C-22992, Class L contact arrangements Shell Size 28, 40 amp rating 28-12, 28-13 Three phase AC, 4 wire, grounding Shell Size 32, 60 amp rating 32-04, 32-05 Single phase AC, 2 ...

Page 10

MIL-C-22992, Class L contact arrangements Shell Size 44, 100 amp rating 44-12, 44-13 Three phase AC, 4 wire, grounding Shell Size 44, 100 amp rating For Navy Ground Support Equipment use only ...

Page 11

MIL-C-22992, Class L alternate insert rotations To avoid cross-plugging problems in applications requiring the use of more than one connector of the same size and arrangement, alternate insert rotations are available as indicated in the accompanying chart. As shown in ...

Page 12

... HOLES H G Dia +.006 H +.016 ±.031 –.010 ±.005 –.000 1.376 1.938 1.514 2.188 1.376 2.188 1.514 2.188 1.438 3.062 1.733 2.532 1.438 3.562 1.733 2.532 8 F* +.011 –.010 .312 .031 ±.005 G N GROMMET GASKET .750 +.031 – ...

Page 13

... Approx. Dia Q K Free Free +.011 Dia. Length Length –.020 Max 7.188 8.188 2.000 2.312 7.188 7.188 8.188 7.188 2.000 2.562 8.688 10.688 9.688 10.172 2.500 3.531 10.688 12.688 11.688 10.172 11.188 2.500 3.531 7.188 17.188 11.109 3.250 4.016 18.188 C ...

Page 14

... E GLAND Max M Dia Free Approx. +.011 Length Free Length –.020 7.188 8.156 2.000 7.188 7.188 8.156 7.188 2.000 8.688 10.688 9.688 10.125 10.688 2.500 12.688 11.688 17.188 11.062 3.250 18.188 M N ...

Page 15

... A Q .750 +.031 INTERFACIAL –.000 SEAL G Dia F* J +.006 +.016 K ±.031 –.010 –.000 ±.005 .959 1.938 2.639 1.557 .959 2.188 2.639 1.557 1.021 3.062 2.998 1.776 1.021 3.562 2.998 1.776 11 (equipment end +.011 Dia. R +.021 –.020 ...

Page 16

MIL-C-22992, Class L Accessories contacts M39029/48 pin contact H C M39029/49 socket contact H All dimensions for reference only. Socket Pin MS Part MS Part Contact Number* Number Size M39029/49-335 M39029/48-327 --- M39029/48-328 4/0N M39029/49-333 M39029/48-323 1/0 --- M39029/48-324 1/0N ...

Page 17

MIL-C-22992, Class L Accessories contact bushing/removal tool MS3348 contact bushing All dimensions for reference only. Contact Wire Barrel Wire MS Part Size Size Number* (Ref) (Ref) MS3348 MS3348 MS3348 ...

Page 18

... Max Min 1.145 1.003 8.000 .844 .688 7.500 1.047 .891 8.000 1.342 1.185 9.500 H 1.516 1.360 11.500 1.688 1.531 13.500 2.328 2.039 18.000 2.500 2.211 19.000 1.750 1.550 12.500 1.578 1.375 12.000 1.160 1.010 8.000 This gland must be used with MS90561 strain relief. ...

Page 19

MIL-C-22992, Class L Accessories protective covers MS90563 protective covers used with: MS90555 wall mount receptacle MS90557 cable connecting receptacle All dimensions for reference only. Use A Thread MS with Class 2B Part Shell .1428P-.2857L Number* Size Double Stub MS90563-1( ) ...

Page 20

MIL-C-22992, Class L installation instructions Complete installation instructions (L-1014) for Class L connectors are available on request. Reproduced below are condensed assembly instructions to familiarize the user with the installation procedure and tooling required. Cable Preparation (MS90556 and MS90557 connectors ...

Page 21

MIL-C-22992, Class L installation instructions MS90555 Connector 5 4 MS90556 Connector Note: On shell size 32 connectors, item #6 (Gland Washer) is contained within item #5 (Back Adaper Wall Mount Receptacle Components: 1. Shell 2. Insert ...

Page 22

MIL-C-22992, Class L installation instructions MS90557 Connector Note: On shell size 32 connectors, item #6 (Gland Washer) is contained within item #5 (Back Adaper). MS90558 Connector ...

Page 23

... S * Available from Pico Crimping Tools Co., 9832 Jersey Ave. Santa Fe Springs, CA 90670 Phone: 805-388-5510 If crimping tools are available, contacts may be affixed to conductors by soldering. Use rosin-alcohol solder flux, a good grade of 60/40 solder and a 500 watt soldering iron or probe type resistance soldering equipment. Pre-tin conductors before soldering ...

Page 24

Heavy Duty Cylindrical MIL-C-22992 QWLD 20 ...

Page 25

... These situations are typical of the extreme conditions under which thousands of Amphenol QWLD connectors are operating daily. Outstanding design features that make these cylindricals a necessity for diffi- cult applications include: • Alumilite 225* hard anodic finish for ...

Page 26

... Crimp type contacts for MIL-C-13777 cable, 85- Crimp type contacts, plated .00005 gold over silver All above prefix numbers utilize connector shells with Alumi- lite* non-conductive finish 88- Solder type contacts, silver plated. Connector shell 2. Base Number - QWLD Series Heavy Duty Cylindrical Con- nector 3. Shell Style - ...

Page 27

MIL-C-22992, QWLD insert arrangements Insert Arrangement Total MS Service Con- Approved Industrial Rating tacts 12-5 D 12-48 A 12-49 A 14-3 A 14-53 Inst. 16-2 E 16-7 A 16-9 A 16-10 A 16-11 A 16-12 A 16-13 A 16-61 A ...

Page 28

MIL-C-22992, QWLD insert arrangements Insert Arrangement Total MS Service Con- Approved Industrial Rating tacts 22- Bal 22- 22- 22-34 D 22- ...

Page 29

QWLD special insert arrangements Insert Total Arrange Service Con- ment Rating tacts 0 4 16- 20- 20- 20- 20- 20- 20-79 A/D 8 22- 22-65 A/D ...

Page 30

... – – 145 215 290 145 215 290 120 240 – 110 250 325 125 235 280 125 235 280 180 270 – 125 245 305 144 216 288 130 235 300 125 225 310 144 216 288 135 225 288 ...

Page 31

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement 12-5 Service Rating D Number of Contacts Contact Size 12 A Insert Arrangement 16-7 Service Rating A Number of Contacts 1 2 Contact ...

Page 32

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement 18-13 Service Rating Number of Contacts 1 3 Contact Size Insert Arrangement 18-20 Service Rating Number ...

Page 33

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement 20-9 Service Rating Bal Number of Contacts 1 7 Contact Size ...

Page 34

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangements Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size B Insert Arrangement Service Rating Number of ...

Page 35

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size C B Insert Arrangement 22-21 Service Rating Number of Contacts Contact Size Insert ...

Page 36

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts ...

Page 37

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Bal Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact ...

Page 38

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated 100˚ Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating ...

Page 39

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated B D Insert Arrangement Service Rating Bal Number of Contacts Contact Size Insert Arrangement ...

Page 40

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts ...

Page 41

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangements Service Rating Number of COntacts ...

Page 42

MIL-C-22992, QWLD contact arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size ...

Page 43

... Ever expanding requirements for more complex circuits in ground equipment and elevated altitude applications has prompted Amphenol to provide inserts not covered by the MS drawings. Pictured here and on the following pages are insert layouts which have anywhere from one contact front face of pin insert or rear of socket insert illustrated ...

Page 44

... Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts 5 2 Contact Size 8 8 for #16 wire *Solderless 24-53 24- 24-65 24- 24-75 24- 24- for # wire 90˚ 24-67 Inst 24-80 Inst CONTACT LEGEND 24- 24- for # wire 90˚ 24- (Coax) RG-188/U or RG-174 ...

Page 45

QWLD special arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of ...

Page 46

QWLD special arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts 6 2 Contact Size 12 0 (Coax) RG-71 ...

Page 47

... Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size **Consult Sidney, NY for service rating of power contacts 36- for #10 wire 36-65 – (Coax) RG-59/U, RG-62/U or RG-71 36- (Coax) RG-187 36- for #10 wire 0 (Coax) RG-11/U RG-12/U or RG-13 36- (Coax) RG-62B ...

Page 48

QWLD special arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact ...

Page 49

QWLD special arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact ...

Page 50

QWLD special arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact Size Insert Arrangement Service Rating Number of Contacts Contact ...

Page 51

QWLD special arrangements front face of pin insert or rear of socket insert illustrated Insert Arrangement Service Rating Number of Contacts Contact Size ...

Page 52

... WIRE WELL DATA Well Inside Dia. Well Depth Contact + .004 + .031 Size – .002 – .000 12 .125 .250 16 .094 .188 RECOMMENDED WIRE Use wire in accordance I Chromel-Alumel with MIL-W-5848 Use wire in accordance II Iron-Constantan with MIL-W-5845 Color Code Black Yellow N/A White Green ...

Page 53

QWLD thermocouple arrangements Shell Size Similar to Total and Arrg. MS Arrg. Contacts 14-59 14-53 6 16-52 16-11 2 16-53 16-9 4 16-55 16-10 3 16-56 16-13 2 16-57 16-10 3 16-58 16-10 3 16-60 16-13 2 16-62 16-11 2 ...

Page 54

... Contact Pin Insert Size Rotation None Ch.; Balance = Cu. 14 None Ir Con None Ch.; Balance = Cu. 8 None Con. ...

Page 55

... QWLD thermocouple arrangements Shell Size Similar to Total and Arrg. MS Arrg. Contacts 24-63 24-28 24 24-64 24-5 16 24-68 24-28 24 24-81 24-7 16 24-88 24-28 24 24-91 24-5 16 28-53 28-11 22 28-58 28-20 14 28-61 28-21 37 28-63 28-20 14 28-64 28-15 35 28-65 28-12 26 28-67 28-16 20 28-68 28-15 35 28-69 28-11 ...

Page 56

... Similar to Total and Arrg. MS Arrg. Contacts 36-86 36-10 48 36-88 36-52 52 40-58 40-56* 85 40-59 40-56* 85 40-77 40-53* 60 40-78 40-53* 60 40-88 40-53 60 40-AA 40-56 85 44-57 44-52 104 44-59 44-52 104 44-60 44-52 104 44-62 44-52 104 * Amphenol arrangement Contact Pin Insert Size Rotation ...

Page 57

... LEFT HAND Dia Thread R +.021 +.004 Class 2A-LH –.020 –.003 (Plated) 1.188 .150 .750-20UNEF 1.281 .150 .875-20UNEF 1.375 .150 1.000-20UNEF 1.500 .177 1.125-18UNEF 1.625 .177 1.250-18UNEF 1.750 .177 1.375-18UNEF 2.000 .177 1.625-18UNEF 2.250 .177 1.875-16UN 2.500 ...

Page 58

... MS part number, see how to order, pg. 22 Thread Class 2A (Plated 0.1P-0.2L +.016 +.021 Double Stub –.000 –.020 12 .8750 .688 .938 14 1.0000 .688 .938 16 1.1250 .688 .938 18 1.2500 .703 .957 20 1.3750 .703 .957 22 1.5000 .703 .957 24 1.7500 .766 1.016 28 2.0000 .766 1.016 32 2 ...

Page 59

... Y Z Max .700 .700 .700 ...

Page 60

... Panel Thread Hex Thickness Class 2A +.017 (Plated) –.016 Min Max 1.000-20UNEF 1.250 .094 .188 1.125-18UNEF 1.312 .094 .188 1.250-18UNEF 1.500 .094 .188 1.375-18UNEF 1.562 .094 .203 1.500-18UNEF 1.750 .094 .203 1.625-18UNEF 1.875 .094 .203 1.875-16UN 2.125 .094 .265 2.125-16UN 2 ...

Page 61

... .150 1.032 1.156 1.500 .177 1.032 1.250 1.625 .177 1.032 1.375 1.750 .177 1.032 1.562 2.000 .177 1.032 1.750 2.250 .177 1.032 1.938 2.500 .209 1.032 2.188 2.750 .209 1.032 2.375 3.000 .209 1.157 2.625 3.250 .209 1.157 2.875 3.500 .209 ...

Page 62

... Dia Class 2A-LH G –.010 Max (Plated) .738 1.156 .750-20UNEF .738 1.281 .875-20UNEF .738 1.469 1.000-20UNEF .738 1.563 1.125-18UNEF .738 1.688 1.250-18UNEF .738 1.844 1.375-18UNEF .800 2.094 1.625-18UNEF .800 2.344 1.875-16UN .875 2.594 2.0625-16UNS .875 2.844 2.3125-16UNS 1.041 3.156 2.625-16UN 1 ...

Page 63

... Min .125 1.000-20UNEF 1.250 .094 .125 1.125-18UNEF 1.312 .094 .188 1.250-18UNEF 1.500 .094 .188 1.375-18UNEF 1.562 .094 .188 1.500-18UNEF 1.750 .094 .188 1.625-18UNEF 1.875 .094 .188 1.875-16UN 2.125 .094 .219 2.125-16UN 2.375 .094 .219 2.375-16UN 2.625 .094 ...

Page 64

MIL-C-22992, QWLD Accessories M85049 or 10-522958 cable sealing adapters (plug 1.500 MAX 1.500 MAX B L 1.500 MAX ...

Page 65

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 66

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 67

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 68

MIL-C-22992, QWLD Accessories M85049 or 10-524959 cable sealing adapters (receptacle ...

Page 69

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 70

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 71

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 72

MIL-C-22992, QWLD Accessories 10-350695 adapter, 10-350349 cable clamp 10-350695-XX( ) adapter C 10-350349-( )3 cable clamp MS3420-( )A sleeve LEFT HAND E A ...

Page 73

... Finish Chart for Adapter & Clamp Suffix -XX1 ...

Page 74

MIL-C-22992, QWLD Accessories protective covers MS17350 10-524915-( ) plug protective cover C MS17349-XXB 10-524916-( ) receptacle protective cover C MS17349-XXA 10-524917-( ) receptacle protective cover ...

Page 75

... 5.000 1.344 1.266 .980 1.2500 .180 5.000 1.469 1.391 .980 1.3750 .180 5.000 1.562 1.516 .980 1.5000 .180 6.000 1.688 1.641 .980 1.7500 .180 6.000 1.938 1.891 .980 2.0000 .180 6.000 2.219 2.141 .980 2.2500 .209 6.000 2.469 2.391 .980 2.5000 ...

Page 76

... –.000 ±.010 ±.010 12 .875 .906 .172 14 1.000 .969 .172 16 1.125 1.063 .203 18 1.250 1.156 .203 20 1.375 1.250 .203 22 1.500 1.375 .203 24 1.750 1.563 .203 28 2.000 1.750 .219 32 2.188 1.938 .219 36 2.437 2.188 .219 40 2.688 2.375 .219 44 2.938 2.625 .219 ...

Page 77

... .750-20UNEF .500 .673 .766 .656 .797 .844 .875-20UNEF .813 .923 .969 1.000-20UNEF .938 1.047 1.094 1.125-18UNEF 1.063 1.172 1.219 1.250-18UNEF 1.188 1.297 1.344 1.375-18UNEF 1.312 1.537 1.469 1.625-18UNEF 1.500 1.797 1.719 1.875-16UN 1.800 2.047 2.000 2.0625-16UN 2.000 2.297 2.219 2.3125-16UN 2.250 2 ...

Page 78

QWLD Accessories encapsulation end bell L C All dimensions are for reference only. Part C Number* Dia +.000 10-130999-13 .766 –.010 +.000 10-130999-15 .844 –.010 +.000 10-130999-17 .969 –.010 +.000 10-130999-18 1.094 –.010 +.000 10-130999-20 1.219 –.015 +.000 10-130999-22 1.344 ...

Page 79

MIL-C-22992, QWLD MS solder contacts Machine copper alloy contacts in a full range of sizes, with closed entry socket design in the size 12 and 16 contacts. A heavy silver-plated finish is deposited on all MS style sol- der contacts ...

Page 80

... Crimp con- tacts are available for all MS insert arrangements and are identified with an ® Amphenol proprietary number. Gold plated contacts are also available (See how to order, page 22). Part ...

Page 81

... QWLD application tools Complete installation instructions (L-615) for Amphenol QWLD Series Connectors are available on request. The following data includes information pertaining to the application tools which have been established for crimp- ing, inserting and removing crimp contacts used in QWLD Series Connectors. Crimping ...

Page 82

... Amphenol Heavy Duty Cylindrical Connectors QWL Series wall mount receptacle cable connecting plug box mount receptacle jam nut receptacle (wall mount) Amphenol tors are tailor made for compact, heavy duty industrial use. The outstanding performance of this series makes it well suited for ship- ...

Related keywords