M8-PHWS Omron, M8-PHWS Datasheet
M8-PHWS
Specifications of M8-PHWS
Related parts for M8-PHWS
M8-PHWS Summary of contents
Page 1
... Size Sensing distance Shielded M8 1.5 mm M12 2 mm M18 5 mm M30 TWO-WIRE PREWIRED MODELS Without Short-CIrcuit Protection Type Size Sensing distance Shielded M8 1.5 mm M12 2 mm M18 5 mm M30 10 mm With Short-CIrcuit Protection Type Size Sensing distance Shielded M18 5 mm M30 10 mm Output ...
Page 2
... Fits M12 size sensors (supplied with each sensor) Fits M18 size sensors (supplied with each sensor) Fits M30 size sensors (supplied with each sensor) Part number Y92E-B8 Y92E-B12 Y92E-B18 Y92E-B30 Part number M8-PHWS M12-PHWS M18-PHWS M30-PHWS 3 E2F ...
Page 3
... RFI immunity Not provided Indicators Target Present (red LED) Materials Housing Plastic Sensing face Plastic Cable sheath Plastic Mounting Two plastic M8 nuts included. Bracket Y92E-B8 optional. Connections Prewired 3-conductor cable (6.56 ft) length Weight with cable Approx (1.4 oz) Enclosure UL — ratings ...
Page 4
... RFI immunity Not provided Indicators Output Operation (red LED) Materials Housing Polyarylate Sensing face Polyarylate Cable sheath Polyvinal Chloride Mounting Two plastic M8 nuts included. Bracket Y92E-B8 optional. Connections Prewired 2-conductor cable (6.56 ft) length Weight with cable Approx (1.4 oz) Enclosure UL — ratings ...
Page 5
E2F Operation OUTPUT CIRCUIT DIAGRAM AND TIMING CHARTS DC 3-Wire Models AC 2-Wire Models With Short-Circuit Protection 6 E2F ...
Page 6
... Shielded M8 and M12 Size Sensors E2F-X1R5 , E2F-X2 Detecting Distance vs. Size and Material of Target Shielded M8 and M12 Size Sensors E2F-X1R5 , E2F-X2 Note: If the target is a nonferrous metal, the operating distance of the proximity sensor decreases. However, with a piece of foil measuring about 0.01 mm (0.0004 in) in thickness, the detecting distance is equivalent to that with a ferrous metal. Note that the proximity sensor cannot detect extremely thin evaporated films and non-conductive targets ...
Page 7
E2F Residual Load Voltage Characteristics Leakage Current Characteristics 8 E2F ...
Page 8
E2F Dimensions Unit: mm (inch) SENSORS DC 3-Wire Models AC-2-Wire Models 9 E2F ...
Page 9
E2F AC Shielded M18 Size without short-circuit protection E2F-X5Y -US OPTIONAL MOUNTING BRACKETS Part number Y92E-B8 Y92E-B12 24 0.2 Y92E-B18 32 0.2 Y92E-B30 45 0.2 AC Shielded M18 Size with short-circuit protection E2F-X5Y -53-US Drawing dimensions ...
Page 10
... A E2F-X2 E2F-X5 mm inch 0.79 35 OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron247.com Canada - http://www.omron.ca Specifications subject to change without notice. E2F Part number Maximum torque kg-cm in-lbs E2F-X1R5 8 6.93 E2F-X2 8 6.93 E2F-X5 -(53)-US 20 17.32 E2F-X10 -(53)-US 20 17. E2F-X10 inch ...