TXD2SS-3V Panasonic, TXD2SS-3V Datasheet - Page 5

Low Signal Relays - PCB 2 Form C 2A 30VDC 3VDC

TXD2SS-3V

Manufacturer Part Number
TXD2SS-3V
Description
Low Signal Relays - PCB 2 Form C 2A 30VDC 3VDC
Manufacturer
Panasonic
Datasheet

Specifications of TXD2SS-3V

Contact Form
2 Form C
Coil Voltage
3 VDC
Coil Current
66.7 mA
Coil Type
Single Side Stable
Power Consumption
200 mW
Contact Carry Current
2 A at 30 VDC
Termination Style
Solder Pad
Isolation
20 dB at 1 GHz
Insertion Loss
0.8 dB at 1 GHz
Maximum Switching Current
2 A
Contact Rating
2 A at 30 VDC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TXD2SS-3V
Manufacturer:
Panasonic
Quantity:
12 000
3) Surface-mount terminal
(1) Tube packing
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
4. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/ Breakdown voltage (between open
contacts) 1,500 V (High breakdown voltage type)
1) Standard PC board terminal
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
arrangement
arrangement
arrangement
arrangement
: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
2 Form C
2 Form C
2 Form C
2 Form C
Contact
Contact
Contact
Contact
2. Please add “-7” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-7-Z)
Nominal coil
Nominal coil
Nominal coil
Nominal coil
1.5V DC
4.5V DC
1.5V DC
4.5V DC
1.5V DC
4.5V DC
1.5V DC
4.5V DC
12V DC
24V DC
12V DC
24V DC
12V DC
24V DC
12V DC
24V DC
voltage
voltage
voltage
voltage
3V DC
5V DC
6V DC
9V DC
3V DC
5V DC
6V DC
9V DC
3V DC
5V DC
6V DC
9V DC
3V DC
5V DC
6V DC
9V DC
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
TXD2S -1.5V-6-Z
TXD2S -3V-6-Z
TXD2S -4.5V-6-Z
TXD2S -5V-6-Z
TXD2S -6V-6-Z
TXD2S -9V-6-Z
TXD2S -12V-6-Z
TXD2S -24V-6-Z
Single side stable
Single side stable
Single side stable
Single side stable
TXD2S -1.5V-6
TXD2S -3V-6
TXD2S -4.5V-6
TXD2S -5V-6
TXD2S -6V-6
TXD2S -9V-6
TXD2S -12V-6
TXD2S -24V-6
TXD2S -1.5V-3
TXD2S -3V-3
TXD2S -4.5V-3
TXD2S -5V-3
TXD2S -6V-3
TXD2S -9V-3
TXD2S -12V-3
TXD2S -24V-3
TXD2-1.5V-3
TXD2-3V-3
TXD2-4.5V-3
TXD2-5V-3
TXD2-6V-3
TXD2-9V-3
TXD2-12V-3
TXD2-24V-3
Part No.
Part No.
Part No.
Part No.
TXD2S -L-1.5V-6-Z
TXD2S -L-3V-6-Z
TXD2S -L-4.5V-6-Z
TXD2S -L-5V-6-Z
TXD2S -L-6V-6-Z
TXD2S -L-9V-6-Z
TXD2S -L-12V-6-Z
TXD2S -L-24V-6-Z
TXD2S -L-1.5V-6
TXD2S -L-3V-6
TXD2S -L-4.5V-6
TXD2S -L-5V-6
TXD2S -L-6V-6
TXD2S -L-9V-6
TXD2S -L-12V-6
TXD2S -L-24V-6
TXD2S -L-1.5V-3
TXD2S -L-3V-3
TXD2S -L-4.5V-3
TXD2S -L-5V-3
TXD2S -L-6V-3
TXD2S -L-9V-3
TXD2S -L-12V-3
TXD2S -L-24V-3
TXD2-L-1.5V-3
TXD2-L-3V-3
TXD2-L-4.5V-3
TXD2-L-5V-3
TXD2-L-6V-3
TXD2-L-9V-3
TXD2-L-12V-3
TXD2-L-24V-3
1 coil latching
1 coil latching
1 coil latching
1 coil latching
Part No.
Part No.
Part No.
Part No.
TX-D

Related parts for TXD2SS-3V