ARA200A4HZ Panasonic, ARA200A4HZ Datasheet - Page 5

Low Signal Relays - PCB 2 Form C, 4.5VDC 2 Form C

ARA200A4HZ

Manufacturer Part Number
ARA200A4HZ
Description
Low Signal Relays - PCB 2 Form C, 4.5VDC 2 Form C
Manufacturer
Panasonic
Datasheet

Specifications of ARA200A4HZ

Contact Form
2 Form C
Coil Voltage
4.5 VDC
Coil Current
31 mA
Coil Type
Single Side Stable
Power Consumption
140 mW
Contact Carry Current
1 A
Termination Style
Solder Pad
Isolation
30 dB at 1 GHz
Insertion Loss
0.3 dB at 1 GHz
Maximum Switching Current
1 A
Contact Rating
10 mA at 10 VDC / 1 A at 30 VDC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
NOTES
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different. The nominal operating voltage
should be applied to the coil for more
than 10 ms to set/reset the latching type
relay.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or
malfunction.
3. External magnetic field
Since RA relays are highly sensitive
polarized relays, their characteristics will
be affected by a strong external magnetic
field. Avoid using the relay under that
condition.
4. Cleaning
For automatic cleaning, the boiling
method is recommended. Avoid
ultrasonic cleaning which subjects the
relays to high frequency vibrations, which
may cause the contacts to stick.
It is recommended that alcoholic solvents
be used.
5. Tape and reel packing
1) Tape dimensions
2) X type, Z type
24.00
.945
X: Picked from 1 pin
Z: Picked from 10 pin
RA relay
16.0
.630
12.30
.484
2.0
.079
(General tolerance: ±0.1 ±.004)
4.0
.157
Tape coming out direction
(10.75)
(.423)
Relay polarity bar
1.75
.069
.059
11.5
.453
1.5
15.2
.598
+0.1
+.004
0
0
dia.
dia.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
0.4
.016
6.4
.252
±0.2
±.008
3) Dimensions of plastic reel
6. Soldering
Manual soldering shall be performed
under following condition.
Tip temperature: 280°C to 300°C
to
Wattage: 30 to 60W
Soldering time: within 5s
In case of automatic soldering, the
following conditions should be observed
1) Position of measuring temperature
2) IR (infrared reflow) soldering method
Temperature rise of relay itself may vary
according to the mounting level or the
heating method of reflow equipment.
Therefore, please set the temperature of
soldering portion of relay terminal and
the top surface of the relay case not to
exceed the above mentioned soldering
condition.
It is recommended to check the
temperature rise of each portion under
actual mounting condition before use.
The soldering earth shall be performed
by manual soldering.
T
T
T
572°F.
.079
1
2
3
2.0
= 150 to 180°C
= 230°C
= Within 250°C
±0.5
±.020
Surface of PC board where relay is mounted.
T
T
T
3
2
1
446°F
and higher
302 to 356°F
482°F
21
.827
13
.512
±0.8
t
±.031
±0.2
1
dia.
±.008
dia.
dia.
24.4
.961
dia.
+2.0
+.079
0
0
t
t
1
2
t
2
= 60 to 120 sec.
= Within 30 sec.
80
3.150
2.0
.079
±1
dia.
±0.2
330
12.992
±.039
±.008
536°F
±2
dia.
dia.
±.079
dia.
7. Conditions for operation, transport
and storage conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
–40 to +70°C
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
(3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage:
2) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the temperature
is lower than 0°C 32°F. This causes
problems such as sticking of movable
parts or operational time lags.
4) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
For general cautions for use, please
refer to the “General Application
Guidelines”.
(Avoid freezing
when used at
temperatures lower
than 0°C
–40
–40
32°F
Tolerance range
Temperature, °C
–40 to +158°F
85
5
+32
0
(Avoid
condensation
when used at
temperatures higher
than 0°C
Humidity, %RH
32°F
RA (ARA)
°F
+158
70