SCX01DNC Honeywell, SCX01DNC Datasheet - Page 3

Board Mount Pressure Sensors 20V 0 psid to 1 psid Guage Transducer

SCX01DNC

Manufacturer Part Number
SCX01DNC
Description
Board Mount Pressure Sensors 20V 0 psid to 1 psid Guage Transducer
Manufacturer
Honeywell
Type
Differential/Gager
Datasheet

Specifications of SCX01DNC

Operating Pressure
0 psi to 1 psi
Pressure Type
Gauge, Differential
Mounting Style
Through Hole
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
20 V
Package / Case
SIP
Output Voltage
5.7 V to 6.3 V
Pressure Range
0 to 1Psi
Overload Pressure (max)
20Psi
Mounting
Through Hole
Pin Count
6
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Operating Supply Voltage (max)
20V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SCX01DNC
Manufacturer:
SIPEX
Quantity:
101
Microstructure Pressure Sensors
Compensated 0 psi to 1psi up to 0 psi to 150 psi
SCX PERFORMANCE CHARACTERISTICS
Characteristic
Zero Pressure Offset
Combined Pressure Non-Linearity and Pressure Hysteresis
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F]
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F]
Repeatability
Input Resistance
Output Resistance
Common Mode Voltage
Response Time
Long Term Stability of Offset and Span
SCX_C SERIES PERFORMANCE CHARACTERISTICS
Characteristic
Zero Pressure Offset
Combined Pressure Non-Linearity and Pressure Hysteresis
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F]
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F]
Repeatability
Input Resistance
Output Resistance
Common Mode Voltage
Response Time
Long Term Stability of Offset and Span
SPECIFICATION NOTES
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
Note 10:
Note 11:
Note 12:
Models: SCX05DNC, SCX15ANC, and SCX15DNC,
Models: SCX01DNC, SCX30ANC, SCX30DNC, SCX100ANC, SCX100DNC,
Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Full-Scale Span is ratiometric to the supply voltage.
Maximum pressure above which causes permanent sensor failure.
Reference Conditions: (Unless otherwise noted)
T
pressure is applied to Port A, and the output polarity is reversed.
For models SCX15AN, SCX30AN, SCX100AN, and SCX150AN,
the Maximum zero pressure offset for absolute devices is 0 to ±500 Microvolt.
Pressure Hysteresis – the maximum output difference at any point within the operating pressure range for increasing and
decreasing pressure.
Maximum error band of the offset voltage and the error band of the span, relative to the 25 °C [77 °F] reading.
Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 70 °C
[32 °F to 158 °F] after:
a) 1,000 temperature cycles, 0 °C to 70 °C [32 °F to 158 °F]
b) 1.5 million pressure cycles, 0 psi to Full-Scale Span.
Input resistance is the resistance between pins 2 and 4.
Output resistance is the resistance between pins 3 and 5.
Common Mode voltage of the output arms (Pins 3 and 5) for V
Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time.
Long term stability over a one-year period.
A
SCX150ANC, and SCX150DNC
= 25°C, Supply V
(7)
(7)
(11)
(11)
(8)
(8)
(9)
(9)
(4)
(10)
(10)
S
= 12 Vdc, Common Mode Line pressure = 0 psig, Pressure applied to Port B. For absolute devices only,
(12)
(12)
(3)
(6)
(6)
(5)
(5)
(6)
(6)
(3)
S
=12 Vdc.
Min.
-300
-1.0
Min.
5.8
5.7
Honeywell • Sensing and Control 3
±100
Typ.
±0.1
±0.2
±0.2
±0.1
100
Typ.
±0.1
±0.2
±0.4
±0.2
±0.2
±0.1
0.0
4.0
4.0
6.0
100
0.0
4.0
4.0
6.0
Max.
±500
±0.5
±0.1
±0.5
300
±1.0
±1.0
±1.0
±2.0
±1.0
±0.5
Max
6.2
6.3
SCX Series
Microvolt
% FSO
% FSO
% FSO
kOhm
kOhm
Vdc
mV
Microvolt
Microsec.
mV
% FSO
% FSO
% FSO
mV
% FSO
kOhm
kOhm
Vdc
Microsec.
mV
Unit
Unit

Related parts for SCX01DNC