33A-100D Measurement Specialties Inc., 33A-100D Datasheet

Industrial Pressure Sensors 0-100psig DIFF. PORT

33A-100D

Manufacturer Part Number
33A-100D
Description
Industrial Pressure Sensors 0-100psig DIFF. PORT
Manufacturer
Measurement Specialties Inc.
Datasheet

Specifications of 33A-100D

Operating Pressure
0 psi to 100 psi
Pressure Type
Differential
Accuracy
+/- 0.05 %
Output Type
Amplified
Supply Current
1.5 mA
Package / Case
TO-8
Output Voltage
100 mV
Port Size
4.6 mm
Pressure Port
Y
Sensor Type
Sensors
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
23 and 33
DESCRIPTION
TO-8 configuration. It provides excellent performance and long-term stability.
compensation is provided over a range of 0-50°C using laser-trimmed resistors. An additional laser-trimmed
resistor is included to normalize pressure sensitivity variations by programming the gain of an external
differential amplifier. This provides sensitivity interchangeability of ±1%.
FEATURES
23 and 33 Standard
STANDARD RANGES
TO-8 Package
0ºC to 50ºC Compensated
Temperature Range
±0.1% Non Linearity
1.0% Interchangeable Span
(provided by gain set resistor)
Solid State Reliability
The 23 and 33 are temperature compensated, piezoresistive silicon pressure sensors packaged in a
Gage and absolute pressure ranges from 0-2 to 0-250 psi are available. Integral temperature
Please refer to the 23 and 33 1 psi datasheets for low pressure applications.
0 to 100
0 to 250
0 to 10
0 to 15
0 to 30
0 to 50
Range
0 to 2
0 to 5
23
Standard
psig
23
33
www.meas-spec.com
1/4
APPLICATIONS
psid
33
Medical Instruments
Process Control
Factory Automation
Handheld Calibrators
Airspeed Measurement
PC Board Mountable Pressure Sensor
0-100 mV Output
Current Excitation
Gage and Differential
Temperature Compensated
September 2010

Related parts for 33A-100D

33A-100D Summary of contents

Page 1

... Gage and absolute pressure ranges from 0-2 to 0-250 psi are available. Integral temperature compensation is provided over a range of 0-50°C using laser-trimmed resistors. An additional laser-trimmed resistor is included to normalize pressure sensitivity variations by programming the gain of an external differential amplifier. This provides sensitivity interchangeability of ±1%. ...

Page 2

... Ratiometric to supply current. 1. Best fit straight line. 2. Maximum temperature error between 0°C and 50°C with respect to 25°C. 3. For a zero-to-full scale pressure step change. 4. Minimum resistance between case and pins. 5. Long term stability over a one year period with constant current and temperature. 6. ...

Page 3

Standard DIMENSIONS CONNECTIONS 23 and 33 Standard www.meas-spec.com 3/4 September 2010 ...

Page 4

... Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. 23 and 33 Standard 33A - 015 D Type (G = Gage) Pressure Range Model ...

Related keywords