E2C-EDA11 2M Omron, E2C-EDA11 2M Datasheet

Proximity Sensors Smart Prox Sensor

E2C-EDA11 2M

Manufacturer Part Number
E2C-EDA11 2M
Description
Proximity Sensors Smart Prox Sensor
Manufacturer
Omron
Datasheet

Specifications of E2C-EDA11 2M

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Separate Amp/
Rectangular
848
Proximity
Information
Cylindrical
Capacitive
Peripheral
E2C-EDA
E2C-EDA
Sensors
Connector
/E2C-H
Pre-wired
Sensing
Devices
General
E2EC
E2CY
Models
Models
Models
Others
E2C
Guide
Models
Finally, a Digital Proximity Sensor!
■ An impressive lineup of Sensor Heads to handle a wide
■ High-resolution sensing unaffected by environmental
■ Simple and reliable measurements with micron-level
■ Support for high-resolution positioning and screening.
Features
An Impressive Lineup of Sensor Heads to Handle a Wide Variety of Applications
An Array of Heads
The lineup includes some Sensor Heads as thin as 3 mm in diameter
and others that are thin and flat. Narrow installation spaces are not a
problem for these models.
Still other Sensor Heads are heat resistant or rated IP67 for superior
environmental resistance. These models are capable of high-
resolution sensing even in harsh environments.
High-resolution Sensing Unaffected by
Environmental Swings
Excellent Temperature Characteristics at 0.08%/°C (5.4-mm-Dia. Sensor Head)
In addition to repeat accuracy of 1- µ m or better, the temperature characteristics of the E2C-EDA are flat.
This means that environmental factors, such as temperature swings in the morning and at night, will not
affect high-resolution positioning and screening.
High-resolution Digital Proximity Sensor with Separate Amplifier
E2C-EDA
variety of applications.
An array of Heads.
Flexible cables provided as a standard feature.
swings. Excellent temperature characteristics at 0.08%/ ° C
(5.4-mm dia. Sensor Head).
resolution.
Two clear, large, and easy-to-read digital displays.
Fine positioning maximizes digital changes.
Flat
Be sure to read Safety Precautions on
page 858.
Heat resist-
ant to 200°C
3 dia.
5.4 dia.
8 dia.
M10
DA
M18
Industry Leader
Flexible Cables Provided as a Standard Feature
With flexible cables connecting the Preamplifier to the Amplifier,
installation on moving parts is never a problem.
The twin-output models can also output an open-circuit alarm. In that
rare instance where the cable breaks, the E2C-EDA can then send
out an alarm that greatly simplifies the task of locating the faulty
Sensor.
Flexible cable
May be cut any length up to 3 m
(models ending in -F)
Temperature Influence (Typical)
5.4-mm dia. E2C-ED01(-@)
0.55
0.50
0.45
Ambient Sensor Head temperature (°C)
−20
Connector
0
20
40
60

Related parts for E2C-EDA11 2M

E2C-EDA11 2M Summary of contents

Page 1

... E2C /E2C-H Excellent Temperature Characteristics at 0.08%/°C (5.4-mm-Dia. Sensor Head) In addition to repeat accuracy of 1- µ better, the temperature characteristics of the E2C-EDA are flat. E2CY This means that environmental factors, such as temperature swings in the morning and at night, will not affect high-resolution positioning and screening. ...

Page 2

... Digital Display Simplifies Installation and Settings In the stable sensing zone, the E2C-EDA generally reads 1,500 or higher (see note 2). This way you can tell at a glance whether the current installation and settings are within the optimal range. Note 2: This reading is only a guideline because there may be some variation between Sensors ...

Page 3

... Two cable lengths are available. (3-dia.: Free-cut, Heat-resistant Models: Standard-length only) Overall length of the Standard-length Models: 2.5 m, Length from Capacitive the Sensor Head to the Preamplifier: 2.0 m (example: E2C-ED01). Overall length of Free-cut Models: 3.5 m, Length from the Sensor Head to the Preamplifier: 0.5 m Models for models ending in the suffix -F (example: E2C-ED01-F) ...

Page 4

... E3X-MC11-C1-SV2 E3X-MC11-H1 E39-Z12-1 Note: Use the E3X-MC11-SV2 Mobile Console with E2C-EDA-series Amplifier Units. If you use a Mobile Console like the E3X-MC11-S, some functions may not operate. Refer to Ratings/Characteristics for the E3X-DA-S/MDA on page 69 for Amplifier Unit specifications. Accessories (Order Separately) Mounting Bracket ...

Page 5

... E2C-EDA Ratings and Specifications Sensor Heads Model E2C-EDR6-F E2C-ED01(-@) 3 dia. × 5.4 dia. × Item Sensing distance 0.6 mm Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data on pages 854 and Sensing object 855.) 5 × 5 × Standard sensing object Material: Iron (S50C) 1 µ ...

Page 6

... Approx. 100 g E2C-EDA Advanced Models with External Inputs E2C-EDA21 E2C-EDA7 E2C-EDA51 E2C-EDA9 Connector Models Approx Proximity Sensors Sensing Guide Cylindrical Models Rectangular Models Separate Amp/ Pre-wired Connector Models Capacitive Models Others Peripheral Devices General Information E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 853 ...

Page 7

... Side length of sensing object d (mm) E2C-EDA E2C-EDA E2C /E2C-H E2CY 854 E2C-ED01(-@) 4000 3000 2000 1500 1000 Fine positioning at 0 0.9 1.2 0.5 1.0 Sensing distance (mm) E2C-EV05(-@) 4000 3000 2000 1500 1000 Fine positioning at 2 2.5 5 10.5 14 Sensing distance (mm) E2C-ED01(-@) 2.0 d × 1.5 1 ...

Page 8

... Ambient Sensor Head temperature (°C) E2C-EM02H 1.1 1.0 0.9 − 100 150 200 Ambient Sensor Head temperature (°C) Proximity Sensors Sensing Guide Cylindrical Models Rectangular Models Separate Amp/ Pre-wired Connector Models Capacitive Models Others Peripheral Devices General Information E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 855 ...

Page 9

... Peripheral ON delay Devices Present Sensing Sensing General object object Not present T Information OFF OFF E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 856 Mode Timing Chart selector Present Sensing object Not present ON Operation indicator (orange) OFF NO ON Output transistor OFF Load (e.g., Operate ...

Page 10

... SET/RUN Mode Selector (Orange) Used to select SET or RUN Fine positioning setting mode VDC Proximity Sensors Sensing Guide Cylindrical Models 12 to Rectangular 24 VDC Models Separate Amp/ Pre-wired Connector Models Capacitive Models Others Peripheral Devices General Information E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 857 ...

Page 11

... Peripheral Devices Lock button General Information E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 858 Connecting and Disconnecting Connectors Connecting (1) Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place. Insert (2) Apply the enclosed seal to the unconnected surface of the Master/ Slave Connector ...

Page 12

... Sensor Head and Amplifier Unit Combinations Be sure to use only specified Sensor Head and Amplifier Unit combinations. The E3C-LDA-series Photoelectric Sensors with Separate Digital Amplifiers are not compatible. The E2C-EDA must not be used with products from that series. Warm-up The digital display may slowly change until the circuits stabilize after the power is turned ON ...

Page 13

... Models Capacitive Models 8 dia. Others Peripheral Devices General Information 15 20.6 E2C-EM02(-F) 18 dia. 16 E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 15 20.6 860 1.7-dia. vinyl-insulated round cable with 1 conductor, -F: 0 5.2 dia. 57 2.5-dia. vinyl-insulated round cable with 1 conductor, Standard length -F: 0 5.2 dia. ...

Page 14

... CAD data 3.4-dia., vinyl-insulated round cable with 3 conductors, Standard length: 0 Connector 18 10 15.8 CAD data Proximity Sensors Sensing Guide Cylindrical Models Rectangular Models Separate Amp/ Pre-wired Connector Models Capacitive Models Others Peripheral Devices General Information E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 861 ...

Page 15

... Rectangular Models Separate Amp/ Pre-wired Connector Models Capacitive Models Others Peripheral Devices General Information E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 862 Circle ( ): Fine positioning indicator Main display Ellipse ( ): Operation indicators (2 channels) Operation Indicator 36.7 With Mounting Bracket Attached 38.8 35.8 21.1 18 ...

Page 16

... Hole for optical communications 34.8 Mounting Bracket (E39-L143): Sold 4.4 separately. Stainless steel (SUS304) 16 CAD data Proximity Sensors Sensing Guide Cylindrical Models Rectangular Models Separate Amp/ Pre-wired Connector Models Capacitive Models Others Peripheral Devices General Information E2EC E2C-EDA E2C-EDA E2C /E2C-H E2CY 863 ...

Page 17

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 18

Cat. No. D814-E1-01 6/06 Specifications subject to change without notice Printed in USA ...

Related keywords