Specifications of E2A-S08LN04-M5-B1

Maximum Operating Temperature
+ 70 C
Supply Voltage
12 VDC to 24 VDC
Supply Current
10 mA
Output Voltage
2 V
Operating Supply Voltage
10 VDC to 32 VDC
Mounting Style
Screw
Sensing Distance
4 mm
Minimum Operating Temperature
- 40 C
Barrel Size
M8
Current Rating
200 mA
Features
Reduces cost and frequency of proximity sensor
Voltage Rating
32 VDC
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
1MHz
Material - Body
Stainless Steel
Shielding
Unshielded
Voltage - Supply
10 V ~ 32 V
Output Type
PNP-NO
Terminal Type
Connector
Package / Case
Cylinder, Threaded - M8
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
42
Control outputs
Combination output boards
with Power Supply (PS)
Setting Options
Power Supply
Product type
Event Inputs
Dimension
DeviceNet
Input type
Transistor
Approvals
Features
Display
Relay
48 H x 96 W x 95 D
(1.89 x 3.78 x 3.74)
• Advanced inspection
• This is ideal for high-speed
• Sampling period is measured
Linear Sensor Indicator
Dual analog inputs:
DC current: 0-20 mA, 4-20 mA
DC voltage: 0-5 V, 1-5 V, ±5 V,
±10 V
5-digit, 7-segment
Negative Transmissive LCD
Front pushbuttons or Serial
communications
5 point NPN;
8 point NPN;
5 point PNP;
8 point PNP
SPDT and 12 VDC PS;
SPDT and 10 VDC PS;
0-20 mA and 12 VDC PS;
0-20 mA and 10 VDC PS;
0-5, 0-10 VDC and 12 VDC PS;
RS-232C and 12 VDC PS;
RS-232C and 10 VDC PS;
RS-485 and 12 VDC PS;
RS-485 and 10 VDC PS
12 VDC only or 10 VDC only
2-SPDT; 4-SPST
5-NPN; 5-PNP
Yes
cULus, CE
controller with high speed
response of 2,000 times per
second
measurement with
discrimination from 1 or 2
independent analog inputs
at 0.5 ms with an output
response time of 1 ms max.
K3HB-S
Digital Panel Meters
48 H x 96 W x 95 D
(1.89 x 3.78 x 3.74)
• Intelligent signal processor
• Multiple ranges can be
• Programmable via serial
• Field replaceable output
Process Meter
DC voltage: 199.99 V, 19,999 V,
1.9999 V, 1.0000 to 5.0000 V;
AC voltage: 0.0 to 400.0 V,
0.00 to 199.99 V, 0.000 to
19.999 V, 0.0000 to 1.9999 V;
DC current: 199.99 mA,
19.999 mA, 1.9999 mA,
4.000 to 20.000 mA;
AC current: 0.000 to 10.000 A,
0.0000 to 1.9999 A,
0.00 to 199.99 mA, 0.000 to
19.999 mA
5-digit, 7-segment
Negative Transmissive LCD
Front pushbuttons or Serial
communications
5 point NPN;
8 point NPN;
5 point PNP;
8 point PNP
SPDT and 12 VDC PS;
SPDT and 10 VDC PS;
0-20 mA and 12 VDC PS;
0-20 mA and 10 VDC PS
0-5, 0-10 VDC and 12 VDC PS;
RS-232C and 12 VDC PS;
RS-232C and 10 VDC PS;
RS-485 and 12 VDC PS;
RS-485 and 10 VDC PS
12 VDC only or 10 VDC only
2-SPDT; 4-SPST
5-NPN; 5-PNP
Yes
cULus, CE
for AC or DC signal or
voltage
covered by a single meter
communications or front
panel
K3HB-X
48 H x 96 W x 95 D
(1.89 x 3.78 x 3.74)
• High-speed temperature
• This unit is also equipped
Temperature Meter
Thermocouples: K, J, T, E, L, U,
N, R, S, B, W;
Platinum resistance: Pt100
5-digit, 7-segment
Negative Transmissive LCD
Front pushbuttons or Serial
communications
5 point NPN;
8 point NPN;
5 point PNP;
8 point PNP
SPDT and 12 VDC PS;
SPDT and 10 VDC PS;
0-20 mA and 12 VDC PS;
0-20 mA and 10 VDC PS;
0-5, 0-10 VDC and 12 VDC PS;
RS-232C and 12 VDC PS;
RS-232C and 10 VDC PS;
RS-485 and 12 VDC PS;
RS-485 and 10 VDC PS
12 VDC only or 10 VDC only
2-SPDT; 4-SPST
5-NPN; 5-PNP
Yes
cULus, CE
indicator with high accuracy
input resolution for both
Platinum resistance and
Thermocouples
with simple input shift using
two points, hysteresis,
peak/hold value, and more
K3HB-H
48 H x 96 W x 95 D
(1.89 x 3.78 x 3.74)
• Ideal weighing indicator for
• Could measure pressure,
Weighing Meter
DC voltage: 0.00 to 199.99 mV,
0.000 to 19.999 mV,
±100.00 mV, ±199.99 mV
5-digit, 7-segment
Negative Transmissive LCD
Front pushbuttons or Serial
communications
5 point NPN;
8 point NPN;
5 point PNP;
8 point PNP
SPDT and 12 VDC PS;
SPDT and 10 VDC PS;
0-20 mA and 12 VDC PS;
0-20 mA and 10 VDC PS;
0-5, 0-10 VDC and 12 VDC PS;
RS-232C and 12 VDC PS;
RS-232C and 10 VDC PS;
RS-485 and 12 VDC PS ;
RS-485 and 10 VDC PS
12 VDC only or 10 VDC only
2-SPDT; 4-SPST
5-NPN; 5-PNP
Yes
cULus, CE
making good/no-good
judgments
load, torque, and weight by
using load cell signal input