TL-N10MY15 Omron, TL-N10MY15 Datasheet - Page 2

no-image

TL-N10MY15

Manufacturer Part Number
TL-N10MY15
Description
Proximity Sensors BLOCK PROXIMITY SENSOR
Manufacturer
Omron
Type
Inductive Proximity Sensorr
Series
TL-Nr
Datasheet

Specifications of TL-N10MY15

Maximum Operating Temperature
+ 70 C
Sensing Distance
10 mm
Minimum Operating Temperature
- 25 C
Features
NO
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
10Hz
Material - Body
ABS Resin
Shielding
Unshielded
Voltage - Supply
90 VAC ~ 250 VAC
Output Type
SCR-NO
Terminal Type
2-Wire
Package / Case
Box
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Accessories (Order Separately)
Mounting Brackets
Ratings and Specifications
DC 2-Wire Models
* The response frequency is an average value.
Mounting Brackets
Mounting Brackets for Conduits
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing
object
Response
frequency
Power supply voltage
(operating voltage
range)
Leakage current
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Protection circuits
Ambient
temperature range
Ambient
humidity range
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
Insulation resistance
Dielectric strength
Vibration
resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*
Load
current
Residual
voltage
Case
Sensing
surface
Type
Model
5 mm ±10%
0 to 4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Iron, 18 × 18 × 1 mm
500 Hz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
3 to 100 mA
3.3 V max. (Load current: 100 mA, Cable length: 2 m)
D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
D1 Models: NO
D2 Models: NC
Load short-circuit protection, Surge suppressor
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
each in X, Y, and Z directions
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Approx. 45 g
Heat-resistant ABS
Instruction manual
TL-Q5MD@
Y92E-C5
Y92E-C10
Y92E-C20
Y92E-N5C15
Y92E-N10C15
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details.
2
Model
3 times
7 mm ±10%
0 to 5.6 mm
Iron, 30 × 30 × 1 mm
Destruction: 1,000 m/s
Approx. 145 g
Mounting Bracket, Instruction manual
TL-N5ME@, TL-N7MD@
TL-N10ME@, TL-N12MD@
TL-N20ME@, TL-N20MD@
Provided with these Sensors
TL-N7MD@
2
---
---
10 times each in X, Y, and Z directions
Applicable Sensors
12 mm ±10%
0 to 9.6 mm
Iron, 40 × 40 × 1 mm
Approx. 170 g
TL-N12MD@
TL-N5MY@
TL-N10MY@
TL-N20MY@
TL-N5ME@, TL-N5MY@
TL-N10ME@, TL-N10MY@
Order separately
TL-N/TL-Q/TL-G
20 mm ±10%
0 to 16 mm
Iron, 50 × 50 × 1 mm
300 Hz
Approx. 240 g
TL-N20MD@
2

Related parts for TL-N10MY15