MAX6657MSA Maxim Integrated Products, MAX6657MSA Datasheet - Page 9

no-image

MAX6657MSA

Manufacturer Part Number
MAX6657MSA
Description
Board Mount Temperature Sensors
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX6657MSA

Full Temp Accuracy
+/- 5 C
Package / Case
SOIC-8 Narrow
Digital Output - Bus Interface
Serial (2-Wire, I2C)
Digital Output - Number Of Bits
10 bit + Sign
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
0 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX6657MSA
Manufacturer:
MAXIM
Quantity:
31
Part Number:
MAX6657MSA
Manufacturer:
MAXIN
Quantity:
38
Part Number:
MAX6657MSA
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX6657MSA
Quantity:
2 300
Part Number:
MAX6657MSA+
Quantity:
35
Part Number:
MAX6657MSA+T
Manufacturer:
MAXIM
Quantity:
1 941
Part Number:
MAX6657MSA+T
0
Company:
Part Number:
MAX6657MSA+T
Quantity:
30
Part Number:
MAX6657MSA-C01060
Manufacturer:
Elantec
Quantity:
10
±1°C, SMBus-Compatible Remote/Local Temperature
ture registers are not updated. The previous data is not
changed and remains available.
From a software perspective, each of the MAX6657/
MAX6658/MAX6659 appears as a series of 8-bit regis-
ters that contain temperature data, alarm threshold
values, and control bits. A standard SMBus-compatible
2-wire serial interface is used to read Temperature Data
and Write Control bits and alarm threshold data. The
device responds to the same SMBus slave address for
access to all functions.
The MAX6657/MAX6658/MAX6659 employ four stan-
dard SMBus protocols: Write Byte, Read Byte, Send
Byte, and Receive Byte (Figures 2, 3, and 4). The short-
er Receive Byte protocol allows quicker transfers, pro-
vided that the correct data register was previously
selected by a Read Byte instruction. Use caution with
the shorter protocols in multimaster systems, since a
second master could overwrite the command byte with-
out informing the first master.
When the conversion rate is greater than 4Hz, temperature
data can be read from the Read Internal Temperature
(00h) and Read External Temperature (01h) registers.
Figure 2. SMBus Protocols
Write Byte Format
Read Byte Format
Send Byte Format
S = Start condition
P = Stop condition
S
ADDRESS
Slave Address: equiva-
lent to chip-select line
ADDRESS
7 bits
7 bits
Slave Address: equiva-
lent to chip-select line of
a 3-wire interface
ADDRESS
7 bits
______________________________________________________________________________________
WR
Shaded = Slave transmission
/// = Not acknowledged
WR
SMBus Digital Interface
ACK
ACK
Sensors with Overtemperature Alarms
WR
Command Byte: sends com-
mand with no data, usually
used for one-shot command
COMMAND
8 bits
Command Byte: selects
which register you are
reading from
COMMAND
8 bits
ACK
ACK
Command Byte: selects which
register you are writing to
ACK
COMMAND
P
8 bits
S
The temperature data format is 7 bits + sign in two's-
complement form for each channel, with the LSB repre-
senting 1°C (Table 2). The MSB is transmitted first.
When the conversion rate is 4Hz or less, the first 8 bits
of temperature data can be read from the Read Internal
Temperature (00h) and Read External Temperature
(01h) registers, the same as for faster conversion rates.
An additional 3 bits can be read from the Read External
Extended Temperature (10h) and Read Internal
Extended Temperature (11h) registers, which extends
the data to 10 bits + sign and the resolution to
+0.125°C per LSB (Table 3).
When a conversion is complete, the Main register and
the Extended register are updated almost simultane-
ously. Ensure that no conversions are completed
between reading the Main and Extended registers so
that when data that is read, both registers contain the
result of the same conversion.
To ensure valid extended data, read extended resolu-
tion temperature data using one of the following
approaches:
1) Put the MAX6657/MAX6658/MAX6659 into standby
Receive Byte Format
mode by setting bit 6 of the Configuration register to
S
Slave Address: repeated
due to change in data-
flow direction
ADDRESS
7 bits
ADDRESS
ACK
7 bits
Data Byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)
RD
DATA
8 bits
RD
ACK
ACK
Data Byte: reads from
the register set by the
command byte
Data Byte: reads data from
the register commanded
by the last Read Byte or
Write Byte transmission;
also used for SMBus Alert
Response return address
DATA
8 bits
DATA
8 bits
ACK
///
///
P
1
P
P
9