LS14500-BA Saft, LS14500-BA Datasheet

no-image

LS14500-BA

Manufacturer Part Number
LS14500-BA
Description
Electronic Battery 3.6V AA 2450 mAh BUTTON
Manufacturer
Saft
Datasheet

Specifications of LS14500-BA

Output Voltage
3.67 V
Chemistry
Lithium
Termination Style
Button
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Primary lithium battery
LS 14500
3.6 V Primary lithium-thionyl chloride (Li-SOCl
High energy density
AA-size bobbin cell
Benefits
G
G
G
G
G
Key features
G
G
G
G
G
G
G
Main applications
G
G
G
G
G
G
G
G
April 2008
(less than 1 % after 1 year of
storage at + 20 °C)
Enhanced capacity
High voltage response, stable
during most of the lifetime of the
application
Wide operating temperature
range (- 60 °C/+ 85 °C)
Easy integration into compact
system
Superior resistance to
atmospheric corrosion
Stainless steel container and end
caps (low magnetic signature)
Hermetic glass-to-metal sealing
Non-flammable electrolyte
Low self-discharge rate
Compliant with IEC 60079 -11
intrinsic safety standard
Underwriters Laboratories (UL)
Component Recognition
(File Number MH 12609)
Non-restricted for transport
Utility metering
Automatic meter reading
Alarms and security devices
Tollgate systems
Memory back-up
Tracking systems
Automotive electronics
Professional electronics
Electrical characteristics
(
Nominal capacity
(at 2 mA + 20 °C 2.0 V cut-off. The capacity restored by the cell varies
according to current drain, temperature and cut-off)
Open circuit voltage
Nominal voltage
Pulse capability: Typically up to 280 mA
(280 mA/0.1 second pulses, drained every 2 mn at + 20 °C from
undischarged cells with 10 μA base current, yield voltage readings above
3.0 V. The readings may vary according to the pulse characteristics, the
temperature, and the cell’s previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current
(Higher currents possible, consult Saft)
Storage
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage readings at the beginning of pulses. Consult Saft)
Physical characteristics
Diameter (max)
Height (max)
Typical weight
Li metal content
Available termination suffix
typical values relative to cells stored for one year or less at + 30 °C max.)
Cell size references
CN, CNR
2 PF, 3 PF, 3 PF RP, 4 PF
CNA (AX)
FL
(at + 20°C)
(at 0.2 mA + 20°C)
(recommended)
(for more severe conditions, consult Saft)
2
)
radial tabs
radial pins
axial leads
flying leads...etc.
14.65 mm (0.58 in)
+ 30°C (+ 86°F) max
50.3 mm (1.98 in)
16.7 g (~ 0.6 oz)
(- 76°F/+ 185°F)
- 60°C/+ 85°C
approx. 0.7 g
R6 - AA
2.6 Ah
3.67 V
70 mA
3.6 V

Related parts for LS14500-BA

LS14500-BA Summary of contents

Page 1

... Saft) Storage (recommended) (for more severe conditions, consult Saft) Operating temperature range (Operation above ambient T may lead to reduced capacity and lower voltage readings at the beginning of pulses. Consult Saft) Physical characteristics Diameter (max) Height (max) Typical weight Li metal content ...

Page 2

... Doc. N 31064-2-0408 Information in this document is subject to change without notice and becomes contractual only after written confirmation by Saft. For more details on primary lithium technologies please refer to Primary Lithium Batteries Selector Guide Doc N Published by the Communications Department. Photo credit: Saft. Socie ´ te ´ anonyme au capital de 31 944 000 RCS Bobigny B 383 703 873 Produced by Arthur Associates Limited ...