PB-300N-48 Mean Well, PB-300N-48 Datasheet

Battery Chargers 300W 57.6V 3.2A 3 STAGE W/O PFC

PB-300N-48

Manufacturer Part Number
PB-300N-48
Description
Battery Chargers 300W 57.6V 3.2A 3 STAGE W/O PFC
Manufacturer
Mean Well
Datasheet

Specifications of PB-300N-48

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
BOOST CHARGE VOLTAGE
FLOAT CHARGE VOLTAGE
VOLTAGE ADJUSTABLE RANGE
RECOMMENDED BATTERY
CAPACITY(AMP HOURS)
BATTERY TYPE
MAX. OUTPUT CURRENT(Typ.)
CONTINUOUS OUTPUT
CURRENT (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
POWER FACTOR (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SHORT CIRCUIT
REVERSE POLARITY
OVER VOLTAGE
OVER TEMPERATURE
REMOTE CONTROL (CN5)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
300W Single Output Battery Charger
P:With Passive PFC
N:Without Passive PFC
Note 6
Note 5
Note 7
Protection type : Automatically derate charge current until zero
Open: Normal work
14.4V
13.6V
13 ~ 14.7V
60 ~ 200Ah
Open & Sealed Lead Acid
20.85A
12.5A
90 ~ 132VAC / 180 ~ 264VAC selected by switch
47 ~ 63Hz
6A/115VAC
PB-300 -12
85%
>0.65 (with P type) at 230VAC
COLD START 60A
<3.5mA / 240VAC
O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on
By internal fuse
16 ~ 18V
Protection type : Shut down o/p voltage, re-power on to recover
-10 ~ +50 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3 (only P type)
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
115.8Khrs min.
253*135*48.5mm(L*W*H)
1.45Kg; 6pcs/9.7Kg/0.95CUFT
0.05%/
(0 ~ 45 )
3A/230VAC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
Short: Stop Charging
PB
O/P-FG:0.5KVAC
300
28.8V
27.2V
26 ~ 28.8V
30 ~ 100Ah
10.5A
6.25A
PB-300 -24
86%
31 ~ 35V
P
127 ~ 187VDC / 254 ~ 370VDC
12
12:14.4V
24:28.8V
48:57.6V
PB-300
57.6V
54.4V
52 ~ 58.6V
15 ~ 50Ah
5.3A
3.2A
PB-300 -48
88%
59 ~ 64V
File Name:PB-300-SPEC 2010-04-12
(except for 48V)
series
(P type only)

Related parts for PB-300N-48

PB-300N-48 Summary of contents

Page 1

... NOTE PB 300 P 12 PB-300 -24 28.8V 27. 28. 100Ah 10.5A 6.25A 127 ~ 187VDC / 254 ~ 370VDC 86% 3A/230VAC 31 ~ 35V Short: Stop Charging ( I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25 ) PB-300 series (except for 48V) (P type only) 12:14.4V 24:28.8V 48:57.6V PB-300 -48 57.6V 54. 58. 50Ah 5.3A 3.2A 88 64V File Name:PB-300-SPEC 2010-04-12 ...

Page 2

... V FLT 80 100 stage 3 30 Green -10 PB-300-48 57.6V 54.4V PB-300 Case No.801B Air flow direction Assignment Mating Housing JST XHP JST SXH-001T-P0.6 or equivalent or equivalent POLARITY REVERSE PROTECTION CIRCUIT EXTERNAL CASE TEMPERATURE ( ) File Name:PB-300-SPEC 2010-04-12 series Unit:mm Terminal fosc : 70KHz + ...