RQ-50D Mean Well, RQ-50D Datasheet

Linear & Switching Power Supplies 53.4W 5V/3A 12V/0.9A 24V/0.9A -12V/0.5A

RQ-50D

Manufacturer Part Number
RQ-50D
Description
Linear & Switching Power Supplies 53.4W 5V/3A 12V/0.9A 24V/0.9A -12V/0.5A
Manufacturer
Mean Well
Datasheet

Specifications of RQ-50D

Product
Switching
Commercial/medical
Commercial
Output Power Rating
15 W
Input Voltage
88 VAC to 264 VAC, 125 VDC to 373 VDC
Number Of Outputs
4
Output Voltage (channel 1)
5 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
0.9 A
Output Voltage (channel 3)
24 V
Output Current (channel 3)
0.9 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RQ-50D
Manufacturer:
TST
Quantity:
5 000
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 6)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
50W Quad Output Switching Power Supply
Note.4
Note.5
Note.3
Note.2
RQ-50B
CH1
5V
5A
0.5 ~ 6A 0.2 ~ 1.5A 0 ~ 1A
45.5W
80mVp-p 120mVp-p 100mVp-p
CH1: 4.75 ~ 5.5V
500ms, 20ms/230VAC
60ms/230VAC
88 ~ 264VAC
47 ~ 63Hz
0.41Kg; 45pcs/19.5Kg/0.9CUFT
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
162.9Khrs min.
99*97*36mm (L*W*H)
74%
1.3A/115VAC
COLD START 36A/230VAC
<2mA / 240VAC
CH1: 5.75 ~ 6.75V
2.0%
0.5%
0.5%
0.03%/
CH2
12V
1A
(0 ~ 50 )on +5V output
6.0%
1.5%
3.0%
(Refer to output load derating curve)
I/P-FG:1.5KVAC
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
MIL-HDBK-217F (25 )
0.8A/230VAC
10ms/115VAC at full load
CH3
-5V
0.5A
2.0%
0.5%
1.0%
1200ms, 30ms/115VAC at full load
CH4
-12V
0.5A
0 ~ 1A
80mVp-p
2.0%
0.5%
1.0%
O/P-FG:0.5KVAC
RQ-50C
CH1
5V
5A
0.5 ~ 6A 0.2 ~ 1.5A 0 ~ 1A
50W
80mVp-p 120mVp-p 100mVp-p
CH1: 4.75 ~ 5.5V
75%
2.0%
0.5%
0.5%
CH2
15V
1A
6.0%
1.5%
3.0%
CH3
-5V
0.5A
2.0%
0.5%
1.0%
CH4
-15V
0.5A
0 ~ 1A
80mVp-p
2.0%
0.5%
1.0%
RQ-50D
CH1
5V
3A
0.5 ~ 6A
53.4W
80mVp-p
CH1: 4.75 ~ 5.5V
R Q - 5 0
79%
2.0%
0.5%
0.5%
CH2
12V
0.9A
0.2 ~ 1.5A
120mVp-p
File Name:RQ-50-SPEC 2010-10-18
6.0%
1.5%
3.0%
CH3
24V
0.9A
0.1 ~ 1A
180mVp-p
+7,-5%
2.0%
3.0%
s e r i e s
CH4
-12V
0.5A
0 ~1A
80mVp-p
2.0%
0.5%
1.0%

Related parts for RQ-50D

RQ-50D Summary of contents

Page 1

... Without damage) 75% 0.8A/230VAC (Refer to output load derating curve) 0.03 )on +5V output I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( RQ-50D CH2 CH3 CH4 CH1 CH2 15V -5V -15V 5V 12V 1A 0.5A 0. ...

Page 2

... DC OUTPUT COM OUTPUT - OUTPUT +V1 RECTIFIERS +V4 & FILTER RECTIFIERS +V3 & FILTER RECTIFIERS +V2 & FILTER RECTIFIERS +V1 & COM FILTER DETECTION CIRCUIT O.V.P. 100 115 120 140 160 180 200 220 240 INPUT VOLTAGE (VAC) 60Hz File Name:RQ-50-SPEC 2010-10- Unit:mm fosc : 60KHz Ta=25 264 ...

Related keywords