ESP-240-54 Mean Well, ESP-240-54 Datasheet

Linear & Switching Power Supplies 216W 54V 4A MTBF 226.6K Hrs.Min

ESP-240-54

Manufacturer Part Number
ESP-240-54
Description
Linear & Switching Power Supplies 216W 54V 4A MTBF 226.6K Hrs.Min
Manufacturer
Mean Well
Datasheet

Specifications of ESP-240-54

Product
Switching
Commercial/medical
Commercial
Output Power Rating
216 W
Input Voltage
88 VAC to 132 VAC, 249 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
54 V
Output Current (channel 1)
4 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
BATTERY
FAN CONTROL
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
EMI CONDUCTION & RADIATION
108W/216W Desktop Power Supply or Charger
Note.3
Note.2
RTH5 80
ESC/ESP-120
13.5V
8A
0 ~ 8A
108W
120mVp-p
12 ~ 15V
200ms, 100ms at full load
36ms at full load
88 ~ 132VAC/176 ~264VAC selected by switch
47 ~ 63Hz
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
3A/115VAC
105 ~ 135% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
15.5 ~ 18.2V
Protection type : Constant voltage limiting, recovers automatically after fault condition is removed
ESC series with bat. polarity, bat. Under voltage, bat. Over voltage protection
NO FAN
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
CSA1010.1(UL3101-1,IEC1010-1,EN61010-1) approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4; ENV50204, light industry level, criteria A
215.8K hrs min.(ESC-120) 200.6K hrs min.(ESC-240) 250.9K Hrs min.(ESP-120)
150*140*86mm (L*W*H)
1.38Kg; 8pcs/12Kg/1.1CUFT(ESC-120)
81%
COLD START 40A
<3.5mA / 240VAC
2.0%
0.5%
2.0%
detect on heatsink of Q1,Q2 power transistor
1.5A/230VAC
I/P-FG:1.5KVAC
27V
4A
0 ~ 4A
108W
150mVp-p
24 ~ 30V
31 ~ 36.5V
83%
1.0%
0.5%
1.0%
O/P-FG:0.5KVAC
54V
2A
0 ~ 2A
108W
400mVp-p
48 ~ 56V
62.1 ~ 72.9V
84%
1.0%
0.5%
0.5%
1.5Kg; 8pcs/13Kg/1.1CUFT(ESC-240)
249 ~ 370VDC
ESC/ESP-120/240
RTH5 85
ESC/ESP-240
13.5V
16A
0 ~ 16A
216W
120mVp-p
12 ~ 15V
200ms, 100ms at full load
30ms at full load
4.5A/115VAC
15.5 ~ 18.2V
RTH5 60
81%
2.0%
1.0%
2.0%
detect on heatsink of Q1,Q2 power transistor
FAN ON, 50
226.6K Hrs min.(ESP-240) MIL-HDBK-217F (25 )
2.5A/230VAC
27V
8A
0 ~ 8A
216W
150mVp-p
24 ~ 30V
31 ~ 36.5V
84%
1.0%
0.5%
1.0%
File Name:ESC/ESP-120/240-SPEC 2010-10-18
FAN OFF
54V
4A
0 ~ 4A
216W
400mVp-p
48 ~ 56V
62.1 ~ 72.9V
85%
1.0%
0.5%
0.5%
series

Related parts for ESP-240-54

ESP-240-54 Summary of contents

Page 1

... EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B (Note 4) HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4; ENV50204, light industry level, criteria A MTBF 215.8K hrs min.(ESC-120) 200.6K hrs min.(ESC-240) 250.9K Hrs min.(ESP-120) 150*140*86mm (L*W*H) OTHERS DIMENSION 1.38Kg; 8pcs/12Kg/1.1CUFT(ESC-120) PACKING NOTE 27V ...

Page 2

... Static Characteristics (ESP-120-27.6) 28 ESC/ESP-240 (HORIZONTAL) 60 120 ESC/ESP-120/240 Case No. 909E 220V 220V Ta= 100 105 110 115 120 125 170 180 190 200 210 220 230 240 250 INPUT VOLTAGE (VAC) 60Hz File Name:ESC/ESP-120/240-SPEC 2010-10-18 series Unit:mm 300 250 200 150 100 50 25 130 260 ...