VTA24SC24 ETA-USA, VTA24SC24 Datasheet - Page 2

no-image

VTA24SC24

Manufacturer Part Number
VTA24SC24
Description
Linear & Switching Power Supplies 24V TO 24V
Manufacturer
ETA-USA
Series
VTAr
Datasheet

Specifications of VTA24SC24

Product
Switching
Output Power Rating
26 W
Input Voltage
19 VDC to 32 VDC
Number Of Outputs
1
Output Voltage (channel 1)
24 VDC
Output Current (channel 1)
1.1 A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
VTA-SC / VTA-SD
Output Voltage
Output Current
Voltage Adjust Range
Ripple Noise(max) *3
Rise up time
Hold up time
Regulation
a. Line Regulation (max)
b. Load Regulation (max)
c. Temperature
d. Drift(maximum) *5
e. Dynamic Load
f. Recovery Time
Conditions:
*1 at cold start
*2 at rated input/output
*3 measured by a bayonet probe at the output connector at a 0 to 100MHz bandwidth
*4 at 0 to +50℃
*5 for 7hour period after 1hour warm-up at 25℃ and rated input/output
*6 when output current changed between 25% and 75% of rated output current rapidly at rated input
Environmental Specification
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Withstanding Voltage
Isolation Resistance
Vibration
Shock
Cooling
Functions
Over current Protection
Over voltage Protection
Remote Sense
Remote On/Off
Reverse Voltage Protection
Line Conduction Noise
Weight
Dimension [mm]
Coefficient
Regulation (typ.)
Characteristic
Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037
ETA USA
Output
[g](typical)
*4
*6
*6
Unit
mVpp
mS
mS
mV
mV
mV
mV
mS
°C
V
A
V
VTA05SCx / SD
5.0
100
150
40
45
40
+/-10% of Rated Output Voltage(at no load within input range)
5
85%RH(non-condensing)
Primary-Secondary
Primary-Secondary-Frame Ground
Current Limiting with automatic recovery
Output shutdown
by internal fuse
0 to +50℃
-20 to +85°C
-
Primary-Frame Ground
Secondary-Frame Ground
insulation tester
5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes'
period for 60minutes each along X,Y,Z axes(non-operating)
294m/s2
Convection
not available
not available
Not specified
380 G
85W × 135L × 31H
VTA12SCx / SD
100mS(maximum) at 25℃ and rated input/output
2.1
170
108
360
12
96
75
VTA15SCx / SD
AC1,500Vfor 1minute (Vin=110
AC1,500V for 1minute (Vin=110
0.03%/℃
Models
0.5mS
10mS
Visit us at:
AC500V for 1minute
1.7
200
120
135
450
email at: sales@eta-usa.com
15
90
www.eta-usa.com
50MΩ(minimum) by DC500V
VTA24SCx / SD
1.1
290
192
216
135
720
24
VTA48SCx / SD
1440
0.5
530
384
432
255
2000)
48
2000)

Related parts for VTA24SC24