IT-60D Mean Well, IT-60D Datasheet

Linear & Switching Power Supplies 58.2W 5V/3A 12V/0.8A 24V/1.4A

IT-60D

Manufacturer Part Number
IT-60D
Description
Linear & Switching Power Supplies 58.2W 5V/3A 12V/0.8A 24V/1.4A
Manufacturer
Mean Well
Datasheet

Specifications of IT-60D

Product
Switching
Commercial/medical
Commercial
Output Power Rating
15 W
Input Voltage
90 VAC to 264 VAC, 137 VDC to 370 VDC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
0.8 A
Output Voltage (channel 3)
24 V
Output Current (channel 3)
1.4 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 5)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD (3sec.)
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
60W Isolated Triple Output Switching Power Supply
Note.3
Note.4
Note.2
IT-60D
CH1
5V
3A
0.5 ~ 3A
58.2W
70W
80mVp-p
CH1 : 4.75 ~ 5.5V
300ms, 20ms/230VAC
80ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
314.3K hrs min.
72 ~ 90W rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, light industry level, criteria A
159*97*38mm (L*W*H)
76%
1.8A/115VAC
COLD START 20A/115VAC
<1mA / 240VAC
5V: 5.75 ~ 6.75V
0.51Kg; 24pcs/13.2Kg/0.75CUFT
3.0%
1.0%
2.0%
0.03%/
(0 ~ 50 )on +5V output
(Refer to output load derating curve)
I/P-FG:1.5KVAC
127 ~ 370VDC
MIL-HDBK-217F (25 )
0.9A/230VAC
18ms/115VAC at full load
CH2
12V
0.8A
0.1 ~ 1A
120mVp-p
8.0%
2.0%
5.0%
800ms, 20ms/115VAC at full load
40A/230VAC
O/P-FG:0.5KVAC
CH3
24V
1.4A
0.2 ~ 2A
240mVp-p
8.0%
2.0%
5.0%
IT-60F
CH1
5V
3A
0.5 ~ 3A
58.2W
80mVp-p
CH1 : 4.75 ~ 5.5V
3.0%
1.0%
2.0%
CH2
15V
0.8A
0.1 ~ 1A
150mVp-p
8.0%
2.0%
5.0%
I T- 6 0
File Name:IT-60-SPEC 2010-10-18
CH3
24V
1.3A
0.2 ~ 2A
240mVp-p
8.0%
2.0%
5.0%
s e r i e s

Related parts for IT-60D

IT-60D Summary of contents

Page 1

... Isolated Triple Output Switching Power Supply SPECIFICATION MODEL IT-60D OUTPUT CH1 DC VOLTAGE 5V RATED CURRENT 3A CURRENT RANGE 0 RATED POWER 58.2W PEAK LOAD (3sec.) 70W Note.4 OUTPUT RIPPLE & NOISE (max.) 80mVp-p Note.2 VOLTAGE ADJ. RANGE CH1 : 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 ...

Page 2

... Isolated Triple Output Switching Power Supply Mechanical Specification 152 4 159 150 6.5 22 117 Block Diagram RECTIFIERS EMI I/P FILTER FG Derating Curve 100 - -10 0 AMBIENT TEMPERATURE ( ) POWER & SWITCHING FILTER PWM O.L.P. CONTROL Static Characteristics 13,16 25 5.2 12,15 24 5.0 11,14 23 4.8 ...