HRP-200-12 Mean Well, HRP-200-12 Datasheet

Linear & Switching Power Supplies 200.4W 12V 16.7A W/PFC

HRP-200-12

Manufacturer Part Number
HRP-200-12
Description
Linear & Switching Power Supplies 200.4W 12V 16.7A W/PFC
Manufacturer
Mean Well
Series
HRP-200r
Datasheet

Specifications of HRP-200-12

Product
Switching
Commercial/medical
Commercial
Output Power Rating
200.4 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
12 VDC
Output Current (channel 1)
16.7 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OVER TEMPERATURE
200W Single Output with PFC Function
Note.5
Note.3
Note.2
40A
95
105
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
3.3V
0 ~ 40A
132W
80mVp-p
2.8 ~ 3.8V
1000ms, 50ms/230VAC
16ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
PF>0.95/230VAC
2.2A/115VAC
35A/115VAC
<1.2mA / 240VAC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.96 ~ 4.62V
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, heavy industry level, criteria A
209.4K hrs min.
199*98*38mm (L*W*H)
0.77Kg; 18pcs/14.9Kg/0.81CUFT
HRP-200-3.3
80%
2.0%
0.5%
1.5%
0.03%/
5 (TSW1) detect on heatsink of power transistor
5
(0 ~ 50
(TSW2)
(Refer to output load derating curve)
5V
35A
0 ~ 35A
175W
90mVp-p
4.3 ~ 5.8V
HRP-200-5
84%
6 ~ 7V
2.0%
0.5%
1.0%
1.1A/230VAC
I/P-FG:1.5KVAC
120 ~ 370VDC
70A/230VAC
MIL-HDBK-217F (25 )
16ms/115VAC at full load
detect on main
PF>0.99/115VAC at full load
2500ms, 50ms/115VAC at full load
HRP-200-7.5
7.5V
26.7A
0 ~ 26.7A
200.3W
100mVp-p
6.8 ~ 9V
86%
9.4 ~ 10.9V
2.0%
0.5%
1.0%
power
O/P-FG:0.5KVAC
output choke
HRP-200-12
12V
16.7A
0 ~ 16.7A
200.4W
120mVp-p
10.2 ~ 13.8V
88%
14.4 ~ 16.8V
1.0%
0.3%
0.5%
HRP-200-15
15V
13.4A
0 ~ 13.4A
201W
150mVp-p
13.5 ~ 18V
88%
18.8 ~ 21.8V
1.0%
0.3%
0.5%
H R P - 2 0 0
HRP-200-24
24V
8.4A
0 ~ 8.4A
201.6W
150mVp-p
21.6 ~ 28.8V
88%
30 ~ 34.8V
1.0%
0.2%
0.5%
File Name:HRP-200-SPEC 2010-12-07
HRP-200-36
36V
5.7A
0 ~ 5.7A
205.2W
250mVp-p
28.8 ~ 39.6V
89%
41.4 ~ 48.6V
1.0%
0.2%
0.5%
HRP-200-48
40.8 ~ 55.2V
48V
4.3A
0 ~ 4.3A
206.4W
250mVp-p
89%
57.6 ~ 67.2V
s e r i e s
1.0%
0.2%
0.5%

Related parts for HRP-200-12

HRP-200-12 Summary of contents

Page 1

... HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, heavy industry level, criteria A EMS IMMUNITY 209.4K hrs min. MTBF OTHERS DIMENSION 199*98*38mm (L*W*H) 0.77Kg; 18pcs/14.9Kg/0.81CUFT PACKING NOTE HRP-200-5 HRP-200-7.5 HRP-200-12 5V 7.5V 12V 35A 26.7A 16. 35A 0 ~ 26. 16.7A 175W 200.3W 200.4W 90mVp-p 100mVp-p 120mVp-p 4 ...

Page 2

... PFC O.L.P. O.T.P. PFC PWM CONTROL CONTROL Output Derating VS Input Voltage 100 (HORIZONTAL) (HORIZONTAL Case No.902E 197 120 199 190 150.75 RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. 90 100 125 135 155 INPUT VOLTAGE (V) 60Hz File Name:HRP-200-SPEC 2010-12- Unit:mm fosc :70KHz + 264 ...

Related keywords