MAP130-4004 POWER ONE, MAP130-4004 Datasheet

Linear & Switching Power Supplies

MAP130-4004

Manufacturer Part Number
MAP130-4004
Description
Linear & Switching Power Supplies
Manufacturer
POWER ONE
Datasheet

Specifications of MAP130-4004

Product
Switching
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Single Output Model Selection
MAP130-1005
MAP130-1012
MAP130-1024
NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
Description
Power-One’s MAP130 Series of single and multiple output power supplies provide fully-regulated outputs with high
peak current capabilities in a compact 4.50" x 8.50" x 2.00" U-channel chassis. Other standard features include autos-
elect AC input, EMI level B filtering, power fail, thermal shutdown (with warning), remote sense, and metric and SAE
mounting inserts.
This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to
50 °C. All products are approved to the latest international regulatory standards and display the CE Mark.
Multiple Output Model Selection
MCD10115 Rev. 1.3, 05-Feb-10
MODEL
MODEL
MAP130-4000
MAP130-4001
MAP130-4002
2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
12V/15V
24V/28V
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
+12V
+24V
+12V
+12V
+12V
-12V
-12V
-12V
+5V
+5V
+5V
-5V
5V
11.4V to 15.75V
4.75V to 5.50V
22.5V to 30.0V
4.75V to 5.50V
11.5V to 12.5V
4.75V to 5.50V
23.0V to 25.0V
4.75V to 5.50V
11.5V to 12.5V
ADJUSTMENT
ADJUSTMENT
RANGE
RANGE
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
6.2A/5.4A (Note 2)
12A/10A (Note 2)
130W Continuous Output Power
CONTINUOUS
CURRENT
CURRENT
OUTPUT
26A
3.5A
20A
20A
20A
5A
1A
1A
1A
1A
5A
1A
1A
Page 1 of 4
CURRENT (NOTE 3)
PEAK CURRENT
13.8A/11A
6.8A/5.9A
(NOTE 1)
PEAK
30A
30A
10A
30A
30A
10A
1A
1A
5A
1A
1A
1A
1A
MAP130 AC-DC Series Data Sheet
Features
REGULATION
REGULATION
RoHS lead-solder-exemption compliant
Automatic 115/230 input voltage selection
All outputs fully regulated
Remote sense, overvoltage protection, and
overtemperature protection
Power Fail signal included
Greater than 100,000 Hour MTBF
U-Channel chassis: 8.50" x 4.50" x 2.00"
(215.9mm x 114.3mm x 50.8mm)
Optional cover
Metric and SAE mounting inserts
0.2%
0.2%
0.2%
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
0.2%
0.5%
0.5%
0.5%
LINE
LINE
REGULATION
REGULATION
LOAD
LOAD
1%
1%
1%
1%
2%
2%
2%
1%
2%
2%
2%
1%
2%
2%
2%
NOISE %p-p (NOTE 1)
NOISE %p-p (NOTE 2)
TYPICAL RIPPLE &
TYPICAL RIPPLE &
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
www.power-one.com
-11.6V to -12.4V
-11.6V to -12.4V
-11.6V to -12.4V
-11.6V to -12.4V
11.75V to 12.0V
12.0V to 12.2V
23.9V to 24.1V
11.6V to 12.4V
INITIAL SETTING
23.9V to 24.1V
11.9V to 12.1V
INITIAL SETTING
-4.8V to -5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
5.1V to 5.2V
ACCURACY
ACCURACY

Related parts for MAP130-4004

MAP130-4004 Summary of contents

Page 1

... NOTES: 1) Typical peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 2) MAP130-1012 output currents are expressed as 12V/15V operation. MAP130-1024 output currents are expressed as 24V/28V operation. 3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. Multiple Output Model Selection ...

Page 2

... Multiple Output Model Selection (Cont.) OUTPUT ADJUSTMENT MODEL VOLTAGE RANGE +5V 4.75V to 5.50V +15V 14.0V to 16.0V MAP130-4003 -5V Fixed -15V Fixed +5V 4.75V to 5.50V +24V 23.0V to 25.0V MAP130-4004 -15V Fixed +15V Fixed +5V 4.75V to 5.50V +12V 11.5V to 12.8V MAP130-4010 -5V Fixed -12V Fixed +5V 4.75V to 5.50V +12V 11.5V to 12.8V MAP130-4020 ...

Page 3

... For convection cooled applications with covers, derate output power as follows: Derate all multiple output models and MAP130-1005 to 120 watts. Derate MAP130-1012 and MAP130-1024 to 140 watts. MCD10115 Rev. 1.3, 05-Feb-10 MAP130 AC-DC Series Data Sheet MAP130-1012 MAP130-1024 MAP130-4004 All other models. Line to Line Line to Ground 2 At 100% load: At 50% load: Page ...

Page 4

... TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. MCD10115 Rev. 1.3, 05-Feb-10 MAP130 AC-DC Series Data Sheet WEIGHT: 2.5 lb (1.13 kg) 0.045" (1.1mm) SQUARE PINS ON 0.156" (3.96mm) CENTERS; ...

Related keywords