S-240-12 Mean Well, S-240-12 Datasheet

Linear & Switching Power Supplies 216W 12V 18A

S-240-12

Manufacturer Part Number
S-240-12
Description
Linear & Switching Power Supplies 216W 12V 18A
Manufacturer
Mean Well
Datasheet

Specifications of S-240-12

Product
Switching
Commercial/medical
Commercial
Output Power Rating
216 W
Input Voltage
88 VAC to 264 VAC, 248 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
12 V
Output Current (channel 1)
18 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
FUNCTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
HARMONIC CURRENT
EMS IMMUNITY
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
FAN CONTROL, O.T.P.
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
MTBF
DIMENSION
PACKING
240W Single Output Switching Power Supply
Note.3
Note.2
5V
40A
0 ~ 40A
200W
150mVp-p
4.5 ~ 5.8V
1000ms, 20ms at full load
36ms at full load
88 ~ 132VAC / 176 ~ 264VAC auto switch
47 ~ 63Hz
78%
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
6 ~ 7V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
RT1 40
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
179.3K hrs min.
190*93*65mm (L*W*H)
1.2Kg; 12pcs/15.3Kg/0.79CUFT
S-240-5
5A/115VAC
15A/115VAC
<2mA / 240VAC
UL60950-1, TUV EN60950-1
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A
2.0%
0.5%
1.0%
0.03%/
(0 ~ 50 )
FAN ON,
(Refer to output load derating curve)
2.5A/230VAC
30A/230VAC
I/P-FG:1.5KVAC
S-240-7.5
7.5V
30A
0 ~ 30A
225W
200mVp-p
6 ~ 9V
80%
9.4 ~ 10.9V
MIL-HDBK-217F (25 )
2.0%
0.5%
1.0%
35
(except for 7.5V), CCC GB4943( for 24V only)
FAN OFF,
14.4 ~ 16.8V
O/P-FG:0.5KVAC
S-240-12
12V
18A
0 ~ 18A
216W
150mVp-p
10 ~ 14V
82%
1.0%
0.5%
0.5%
70
248 ~ 370VDC
output shutdown
18.5 ~ 21.5V
S-240-15
15V
15A
0 ~ 15A
225W
150mVp-p
12 ~ 18V
83%
1.0%
0.5%
0.5%
approved
24V
10A
0 ~ 10A
240W
180mVp-p
20 ~ 28V
84%
31.2 ~ 36V
S-240-24
1.0%
0.5%
0.5%
S - 2 4 0
S-240-30
30V
8A
0 ~ 8A
240W
180mVp-p
27 ~ 33V
85%
34.5 ~ 40.5V
1.0%
0.5%
0.5%
File Name:S-240-SPEC 2010-10-18
57.6 ~ 67.2V
S-240-48
48V
5A
0 ~ 5A
240W
240mVp-p
41 ~ 56V
87%
1.0%
1.0%
1.0%
s e r i e s

Related parts for S-240-12

S-240-12 Summary of contents

Page 1

... HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light industry level, criteria A EMS IMMUNITY MTBF 179.3K hrs min. 190*93*65mm (L*W*H) OTHERS DIMENSION 1.2Kg; 12pcs/15.3Kg/0.79CUFT PACKING NOTE S-240-7.5 S-240-12 7.5V 12V 30A 18A 0 ~ 30A 0 ~ 18A 225W 216W 200mVp-p 150mVp 14V 2.0% 2.0% 1 ...