MENB1060A0903N01 SL Power, MENB1060A0903N01 Datasheet

Plug-In AC Adapters 54W 9V @ 6A - C8 Desktop/ MEDICAL V

MENB1060A0903N01

Manufacturer Part Number
MENB1060A0903N01
Description
Plug-In AC Adapters 54W 9V @ 6A - C8 Desktop/ MEDICAL V
Manufacturer
SL Power
Datasheet

Specifications of MENB1060A0903N01

Mounting Style
Desktop
Input Voltage (nominal)
100 VAC to 240 VAC
Number Of Outputs
1
Output Power Rating
54 W
Output Voltage (channel 1)
9 V
Output Current (channel 1)
6 A
Dc Output Connector
2.5 mm Barrel Plug
Dc Output Cord Length
1450 mm
Ac Plug Included/required
Required
Commercial/medical
Medical
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specifications
AC Input
Input Current
Inrush Current
Input Fuse
Efficiency
Output Voltage
Output Power
Ripple and Noise
Line/Load Voltage Regulation
Transient Response
Minimum Load
Case Material
Case Dimensions
Weight
Conducted Emissions
Radiated Emissions
Line Frequency Harmonics
Voltage Fluctuations/Flicker
Static Discharge Immunity
Radiated RF Immunity
EFT/Burst Immunity
Line Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field Immunity
Voltage Dip Immunity
MENB1060
Universal Input 60 Watt Series
Medical Switch-Mode Power Supply
•100-240VAC Universal Input
•Meets EISA2007, CEC Efficiency Level V,
•Certified to UL/EN60601-1
•Desktop Style
•5V to 24V Single Output Models, up to 60W
•Modified and Custom Designs Available
•Regulated Output with Low Ripple
•Impact-Resistant Polycarbonate Enclosure
•No Load Power Consumption <0.5W
EU (EC) No 278/2009 Phase II
SL Power Electronics Corp
______________________________________________________________________________________________________________________________
2.0A, 250V Internal Primary Current Fuse is provided
Meets EISA2007, CEC Efficiency Level V,
RoHS
6050 King Drive Ventura, CA 93003
500µs max., 50% load step, typical
100-240Vac, -/-10%, 47-63 Hz, 1∅
EU (EC) No 278/2009 Phase II
60 A peak, 264 V, cold start
1% pk-pk max., 20MHz BW
Black 94V0 Polycarbonate
Line: +/- 1%, Load: +/-5%
See outline drawing
100VAC: 1.5A max
Not required
All Specifications are typical at nominal input, full load at 25
See chart
See chart
EMC Specifications
Phone 805.486.4565 • Fax 858.712.2040
400g
MTBF
Hold-up Time
Overload Protection
Short Circuit Protection
Topology
Safety Standards
EMC
Dielectric Withstand
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Output Cable 5V – 9V models: #18AWG (UL2464), 1,200mm, 4 conductor
Output Connector
EN55011 Class B, FCC Part 15, Class B.
EN55011 Class B, FCC Part 15, Class B.
EN61000-3-2, Class A
EN61000-3-3
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
EN61000-4-3, 3V/m.
EN61000-4-4, 2kV/5kHz.
EN61000-4-5, 1kV differential, 2kV common-mode
EN61000-4-6, 3Vrms
EN61000-4-8, 3A/m
EN61000-4-11, Criteria A
Other models: 2.5mm barrel type (Ault #3), center contact positive (+)
12V – 15V models: #18AWG (UL2464), 1,500mm, 4 conductor
18V – 24V models: #18AWG (UL2464), 1,500mm, 2 conductor
3 Year Warranty
5V model: Molex 39-01-2060 or equiv. (Ault #51)
Email: info@slpower.com
18 ms min. @ 115Vac, 60 ms min. @ 240 Vac
Input-GND: 1,500 Vac, Output-GND: 500Vdc
Switching – Fixed Frequency Flyback
°
C unless otherwise stated.
5% to 95%, non-condensing
>100,000 hours (calculated)
EN/IEC/CSA/UL60601-1
Input-Output: 5,656Vdc,
0° to 40°C, no derating
www.slpower.com
See chart below
Hiccup Mode
0 to 10,000 ft
Hiccup Mode
-30 to +85°C
1 of 2

Related parts for MENB1060A0903N01

MENB1060A0903N01 Summary of contents

Page 1

... Radiated RF Immunity EFT/Burst Immunity Line Surge Immunity Conducted RF Immunity Power Frequency Magnetic Field Immunity Voltage Dip Immunity ______________________________________________________________________________________________________________________________ SL Power Electronics Corp • 6050 King Drive Ventura, CA 93003 All Specifications are typical at nominal input, full load at 25 MTBF 100VAC: 1.5A max Hold-up Time ...

Page 2

... Dimensions are in mm (Cable length is 1200mm on 5V thru 12V models) Data Sheet © 2010 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. ...