DS21Q41BT Maxim Integrated Products, DS21Q41BT Datasheet - Page 25

IC FRAMER T1 QUAD 128-TQFP

DS21Q41BT

Manufacturer Part Number
DS21Q41BT
Description
IC FRAMER T1 QUAD 128-TQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS21Q41BT

Controller Type
T1 Framer
Interface
Parallel/Serial
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
128-TQFP, 128-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS21Q41BT
Manufacturer:
DS
Quantity:
3 279
Part Number:
DS21Q41BT
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q41BT
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
DS21Q41BTN
Manufacturer:
DALLAS
Quantity:
104
Part Number:
DS21Q41BTN
Quantity:
715
SR1: STATUS REGISTER 1 (Address=20 Hex)
(MSB)
LUP
SYMBOL
RSLIP
LOTC
RYEL
RLOS
LDN
RBL
RCL
LUP
LDN
POSITION
SR1.7
SR1.6
SR1.5
SR1.4
SR1.3
SR1.2
SR1.1
SR1.0
LOTC
NAME AND DESCRIPTION
Loop Up Code Detected. Set when the repeating ...00001...
loop up code is being received.
Loop Down Code Detected. Set when the repeating ...001...
loop down code is being received.
Loss of Transmit Clock. Set when the TCLK pin has not
transitioned for one channel time (or 5.2 s). Will force the
RLOS/LOTC pin high if enabled via CCR1.6. Also will force
transmit side formatter to switch to RCLK if so enabled via
TCR1.7. Based on RCLK.
Receive Elastic Store Slip Occurrence. Set when the receive
elastic store has either repeated or deleted a frame.
Receive Blue Alarm. Set when an unframed all ones code is
received at RPOS and RNEG.
Receive Yellow Alarm. Set when a yellow alarm is received at
RPOS and RNEG.
Receive Carrier Loss. Set when 192 consecutive 0s have been
detected at RPOS and RNEG.
Receive Loss of Sync. Set when the device is not synchronized
to the receive T1 stream.
RSLIP
25 of 61
RBL
RYEL
RCL
RLOS
DS21Q41B
(LSB)

Related parts for DS21Q41BT