JWS300-24 TDK Corporation, JWS300-24 Datasheet

no-image

JWS300-24

Manufacturer Part Number
JWS300-24
Description
Power Supply; 24 V; 14 A (Max.); 85-265 VAC/120-330 VDC; 144 mV; 96 mV; 63 Hz
Manufacturer
TDK Corporation
Type
Industrialr
Datasheet

Specifications of JWS300-24

Brand/series
JWS Series
Configuration
Enclosed
Current, Output
14 A (Max.)
Frequency, Operating
63 Hz
Line Regulation
96 mV
Load Regulation
144 mV
Number Of Outputs
1
Output
24 VDC @ 14 A
Power, Output
300 W
Primary Type
AC-DC
Special Features
Parallelable, PFC, Remote On/Off, Remote Sense
Standards
UL Listed, CSA Certified, EN60950, VDE Approved, CE Approved, Built to Meet DENTORI
Temperature, Operating
-10 to 65 °C
Voltage, Input
85 to 265/120 to 330 VAC/VDC
Voltage, Output
24 VDC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JWS300-24
Manufacturer:
CINCON
Quantity:
12 000
Part Number:
JWS300-24
Quantity:
106
Enclosed or L Bracket
(One
DIN Rail Mount
* See website
High Reliability
Programmable
Applications
Commercial
PCB Mount
(Three Year
(Five Year
Warranty)
Warranty)
Warranty)
Industrial
Industrial
Datacom
Linear
- T
wo ear
Y
Rack Mount Hot Swap
# of Outputs
Single &
Multiple
Multiple
Open Frame
Single
Single
Single
Single
Triple
Dual
Desktop
5
KW, KPS, KM
10
HK-A(SingleOutput,1 1 5VAC input)
AC-DC Selector
KW, KM
ZWS, ZWSAF, ZWSPAF
15
LWD, LWT
NND
30
MTW
NNS
DSP , DPP , DLP-PU*
DT
SC, SC1 20, ZP
DT
Output Power (W)
H
SC, ZP
LS
H
50
JWT
ZWD,ZWQ
100
DLP
HWS
JWS
SWS
300
ZUP
NV
500 1000 1500 2500
Vega
PFE
LZSA
Alpha
TH (1U)
FPS(1U)

Related parts for JWS300-24

JWS300-24 Summary of contents

Page 1

Linear Desktop Enclosed or L Bracket Open Frame PCB Mount Rack Mount Hot Swap Applications # of Outputs High Reliability Single Industrial (Five Year Warranty) Dual Triple Industrial Single & (Three Year Multiple Warranty) Single Datacom Commercial (One - T ...

Page 2

... Not Available Not Available -10ºC~+60ºC, derate linearly to 60% load from 50ºC~60ºC -10ºC~+50ºC, derate linearly to 60% load from 40ºC~50ºC (JWS50-150) -10ºC~+65ºC, derate linearly to 55% load from 50ºC~65ºC (JWS300-600) -30 to +85º 90 95% RH JWS50 - JWS150 Convection, JWS300 & JWS600 Internal fan Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min ...

Page 3

... JWS50-24/A 24.0V 21.6 - 26.4 2.2 JWS75-24/A 24.0V 21.6 - 26.4 3.2 JWS100-24/A 24.0V 21.6 - 26.4 4.5 JWS150-24/A 24.0V 21.6 - 26.4 6.5 JWS300-24 24.0V 21.6 - 28.8 14 JWS600-24 24.0V 21.6 - 28.8 27 JWS50-28/A 28.0V 25.2 - 30.8 2 JWS100-28/A 28.0V 25.2 - 30.8 3.6 JWS150-28/A 28.0V 25 ...

Related keywords