G7L1ABUBJCBAC100120 Omron Automation, G7L1ABUBJCBAC100120 Datasheet

no-image

G7L1ABUBJCBAC100120

Manufacturer Part Number
G7L1ABUBJCBAC100120
Description
RELAY; E-MECH; GEN PURP; SPST-NO; CUR-RTG 30A; CTRL-V 100/120AC; VOL-RTG 250AC; SCREW
Manufacturer
Omron Automation
Datasheet

Specifications of G7L1ABUBJCBAC100120

Contact Form
SPST-NO
Current, Rating
30 A
Dielectric Rating
5000 VAC (Typ.)
Dimensions
2.696 Inches L (Max.) x 1.318 Inches W (Max.) x 1.85 Inches H (Max.)
Function
General Purpose
Material, Contact
Silver Alloy
Mounting Type
Bracket
Power, Rating
6600 VA
Relay Type
Electro Mechanical
Resistance, Coil
5260 Ohms
Resistance, Contact
50 Milliohms (Max.)
Standards
UL, CSA, CE
Termination
Screw
Voltage, Control
110 VAC
Voltage, Rating
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
• Ideally suited for high-inrush fluid pump controls: pool/spa,
• High-capacity, high-withstand voltage relay with no contact
• UL Class B construction standard.
• Wide-range AC-activated coil that handles 100 to 120 VAC
• Miniature hinge for maximum switching capacity, particular-
• Flame resistant materials (UL94V-0-qualifying) used for
• Quick-connect, screw, and PCB terminals available.
• Standard models are UL, CSA, and TUV approved;
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to “Accessories” section for options and part numbers.
E bracket
E bracket
(with test button)
Upper bracket
Upper bracket
(with test button)
PCB mounting
water processing, emergency, chemical industry, etc.
chattering for momentary voltage drops up to 50% of rated
voltage.
at either 50 or 60 Hz.
ly for inductive loads.
all insulation material.
VDE/IEC 950 versions are now available. Meet pollution
degree 3, Material Group II & III.
General Purpose Relay
G7L
2. For VDE approved versions, please consult OMRON.
Type
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
Contact form
G7L-1A-T-CB
G7L-2A-T-CB
G7L-1A-TJ-CB
G7L-2A-TJ-CB
G7L-1A-TUB-CB
G7L-2A-TUB-CB
G7L-1A-TUBJ-CB
G7L-2A-TUBJ-CB
Quick-connect terminal
(see note 1)
(see note 1)
(see note 1)
(see note 1)
G7L-1A-B-CB
G7L-2A-B-CB
G7L-1A-BJ-CB
G7L-2A-BJ-CB
G7L-1A-BUB-CB
G7L-2A-BUB-CB
G7L-1A-BUBJ-CB
G7L-2A-BUBJ-CB
General Purpose Relay
Screw terminal
Model
(see note 1)
(see note 1)
(see note 1)
(see note 1)
G7L-1A-P-CB
G7L-2A-P-CB
G7L
PCB terminal
1

Related parts for G7L1ABUBJCBAC100120

G7L1ABUBJCBAC100120 Summary of contents

Page 1

General Purpose Relay G7L • Ideally suited for high-inrush fluid pump controls: pool/spa, water processing, emergency, chemical industry, etc. • High-capacity, high-withstand voltage relay with no contact chattering for momentary voltage drops up to 50% of rated voltage. • UL ...

Page 2

Model Number Legend G7L- ❏ ❏ - ❏ ❏ ❏ ❏ Contact form 1A:SPST-NO 2A:DPST-NO 2. Terminal shape T:Quick-connect terminals P:PCB terminals B:Screw terminals ■ Accessories Quick-connect Terminals Description E-brackets G7L-1A-T Track ...

Page 3

Coil Data AC Rated voltage Rated current (V) (mA) 6 283 18.90 12 142 303 50 34 1,310 100/120 17.00/20.40 5,260 200/240 8.50/10.20 21,000 DC Rated voltage Rated current (V) (mA) 6 317 18.90 12 158 ...

Page 4

Characteristic Data Maximum switching capacity Switching voltage (V) Dimensions Unit: mm (inch) ■ Relays G7L-1A-T (E Bracket Attached)* G7L-2A-T (E Bracket Attached bracket must be ordered separately. 4 General Purpose Relay Electrical service life Terminal arrangement/ Internal ...

Page 5

G7L-1A-TJ (E Bracket Attached)* G7L-2A-TJ (E Bracket Attached)* G7L-1A-TUB G7L-2A-TUB *E bracket must be ordered separately. Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) ...

Page 6

Unit: mm (inch) G7L-1A-TUBJ G7L-2A-TUBJ G7L-1A-B (E bracket Attached)* G7L-2A-B (E bracket Attached bracket must be ordered separately. 6 General Purpose Relay Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections ...

Page 7

G7L-1A-BJ (E bracket Attached)* G7L-2A-BJ (E bracket Attached)* G7L-1A-BUB G7L-2A-BUB * E bracket must be ordered separately. Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top ...

Page 8

Unit: mm (inch) G7L-1A-BUBJ G7L-2A-BUBJ G7L-1A-P G7L-2A-P 8 General Purpose Relay Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) Terminal arrangement/ Internal connections (Top view) G7L Mounting holes (Bottom view) ...

Page 9

Approvals UL recognized type (File No. E41643)/CSA certified type (File No. LR35535) Type Contact form G7L-1A-T-CB SPST-NO G7L-1A-TJ-CB G7L-1A-TUB-CB G7L-1A-TUBJ-CB G7L-1A-B-CB G7L-1A-BJ-CB G7L-1A-BUB-CB G7L-1A-BUBJ-CB G7L-1A-P-CB G7L-2A-T-CB DPST-NO G7L-2A-TJ-CB G7L-2A-TUB-CB G7L-2A-TUBJ-CB G7L-2A-B-CB G7L-2A-BJ-CB G7L-2A-BUB-CB G7L-2A-BUBJ-CB G7L-2A-P-CB TÜV (File No. R9251551) ...