RA2450-D06 Carlo Gavazzi, Inc., RA2450-D06 Datasheet

no-image

RA2450-D06

Manufacturer Part Number
RA2450-D06
Description
Relay; SSR; Zero-Switching; Cur-Rtg 50A; Ctrl-V 3-32DC; Vol-Rtg 230AC; Screw; UL, CSA
Manufacturer
Carlo Gavazzi, Inc.
Datasheet

Specifications of RA2450-D06

Capacitance
8 pF (Max.)
Current, Rating
50 A
Current, Surge, Non-repetitive Peak
600 A
Dielectric Strength
4000 VAC (RMS) (Min.)
Dimensions
45.5 mm L x 58.2 mm W x 30 mm H
Function
Zero-Switching
Relay Type
Solid State
Standards
UL, CSA
Temperature, Operating, Maximum
+100 °C
Temperature, Operating, Minimum
-40 °C
Termination
Screw
Voltage, Control
32 VDC
Voltage, Rating
230 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Solid State Relays
Industrial, 1-Phase ZS, Standard Range
Types RA 24.. .. 06/RA 44.. .. 08/RA 48.. .. 12
Product Description
Type Selection
Switching mode
A: Zero switching
Rated opera- Blocking
tional voltage voltage
230 VACrms
400 VACrms
480 VACrms
The zero switching relay with
antiparallel thyristor output is
the most widely used indus-
trial SSR due to its multiple
application possibilities. The
relay can be used for resis-
2-60
Selection Guide
650 V
850 V
1200 V
p
p
p
Rated operational
voltage
24: 230 VACrms
44: 400 VACrms
48: 480 VACrms
Control voltage
3 to 32 VDC
10 to 90 VAC/DC
90 to 280 VAC/DC
3 to 32 VDC
10 to 90 VAC/DC
90 to 280 VAC/DC
3 to 32 VDC
10 to 90 VAC/DC
90 to 280 VAC/DC
tive, inductive and capacitive
loads. The zero switching re-
lay switches ON when the
sine curve just crosses zero
and switches OFF when the
current crosses zero.
Rated operational current
10 AACrms
RA 2410 -D 06
RA 2410 LA 06
RA 2410 HA 06
RA 4410 -D 08
RA 4410 LA 08
RA 4410 HA 08
RA 4810 -D 12
RA 4810 LA 12
RA 4810 HA 12
Rated operational
current
10: 10 AACrms
25: 25 AACrms
50: 50 AACrms
90: 90 AACrms
Ordering Key
Solid State Relay
Switching mode
Rated operational voltage
Rated operational current
Control voltage
Blocking voltage
AC Solid State Relay
Zero switching
Direct copper bonding technology
Rated operational current: 10, 25, 50 and 90 AACrms
Blocking voltage: Up to 1200 V
Rated operational voltage: Up to 480 VACrms
3 input ranges: 3 to 32 VDC, 10 to 90 VAC/DC and
90 to 280 VAC/DC
Isolation: OPTO (input-output) 4000 VACrms
Specifications are subject to change without notice (28.02.2007)
25 AACrms
RA 2425 -D 06
RA 2425 LA 06
RA 2425 HA 06
RA 4425 -D 08
RA 4425 LA 08
RA 4425 HA 08
RA 4825 -D 12
RA 4825 LA 12
RA 4825 HA 12
Control voltage
-D: 3 to 32 VDC
LA: 10 to 90 VAC/DC
HA: 90 to 280 VAC/DC
50 AACrms
RA 2450 -D 06
RA 2450 LA 06
RA 2450 HA 06
RA 4450 -D 08
RA 4450 LA 08
RA 4450 HA 08
RA 4850 -D 12
RA 4850 LA 12
RA 4850 HA 12
RA 24 10 LA 06
p
Blocking voltage
06: 650 V
08: 850 V
12: 1200 V
90 AACrms
RA 2490 -D 06
RA 2490 LA 06
RA 2490 HA 06
RA 4490 -D 08
RA 4490 LA 08
RA 4490 HA 08
RA 4890 -D 12
RA 4890 LA 12
RA 4890 HA 12
p
p
p

Related parts for RA2450-D06

RA2450-D06 Summary of contents

Page 1

... ON when the trial SSR due to its multiple sine curve just crosses zero application possibilities. The and switches OFF when the relay can be used for resis- current crosses zero. Type Selection Switching mode Rated operational ...

Page 2

RA 24.. .. 06, RA 44.. .. 08 General Specifications RA 24 Operational voltage range 24 to 280 VACrms Blocking voltage 650 V Zero voltage turn- Operational frequency range ...

Page 3

RA 24.. .. 06, RA 44.. .. 08 Isolation Rated isolation voltage Input to output Rated isolation voltage Output to case Insulation resistance Input to output Insulation resistance Ouput to case Insulation capacitance Input to output ...

Related keywords