2-5700-IG1-K10-DD-20A E-T-A Circuit Protection and Control, 2-5700-IG1-K10-DD-20A Datasheet

no-image

2-5700-IG1-K10-DD-20A

Manufacturer Part Number
2-5700-IG1-K10-DD-20A
Description
Circuit Breaker; Therm; Push; Cur-Rtg 20A; Panel; 1 Pole; Vol-Rtg 250/28VAC/VDC
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 2-5700-IG1-K10-DD-20A

Actuator Type
Push
Application
Motors, transformers, solenoids, battery chargers, power supplies, appliances, machinery and extra low voltage systems
Brand/series
2-5700 Series
Color, Button
Black
Current, Rating
20 A
Dielectric Strength
3000
Dimensions
1.14"Lx0.571"Wx1.83"H
Mounting Hole Size
0.378x0.35 "
Mounting Type
Panel
Number Of Poles
1
Resistance, Insulation
100 Megohms (Min.)
Standards
UL Listed, CSA Certified, VDE and EN 60934 (IEC 60934)
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-20 °C
Termination
Screw
Voltage, Rating
250/28 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Single pole thermal circuit breaker with press-to-reset, tease-free, trip-
free, snap action mechanism. Type 2-5000 is available with optional
manual release (-H), type 2-5700 can be supplied as a push-push
switch/circuit breaker (R-type TO CBE to EN 60934 in press-to-reset
configuration; M-type when fitted with manual release -H; S-type with
push-push operation). Fitted with flange or threadneck for panel
mounting. Options include an additional unprotected circuit tap (-A3).
Approved to CBE standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, battery chargers, power supplies,
appliances, machinery, extra low voltage systems.
Type No.
2-5000
2-5700
2-5700 - iG1 - P10 - .. - DD - 8 A
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Current
rating (A)
0.05
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
1.2
1.5
1.8
2
2.5
Issue B
Description
Typical applications
Ordering information
Standard current ratings and typical internal resistance values
(hardware bulk shipped)
flange mounting
threadneck panel mounting
Threadneck design – type 2-5700 only
iG1
iG2
moulded threadneck 3/8"-27UNS-2A
moulded threadneck M12x1
Terminal design
P10
K10
Internal
resistance (Ω)
280
100
110
29
14
7
4.9
3.4
2.5
1.8
1.2
0.8
0.6
0.4
0.3
0.2
blade terminals 6.3-0.8 mm (QC .250)
screw terminals M4x6
Shunt terminal (optional) -P10 only
A3
Thermal Overcurrent Circuit Breakers 2-5000/2-5700-...
shunt terminal (up to I
Manual release (optional)
H
DD
manual release facility (type 2-5000 only)
push to release/push to reset (type 2-5700 only)
Current ratings
0.05...25 A
ordering example
Current
rating (A)
3
3.5
4
4.5
5
6
7
8
10
12
13
15
16
20
22
25
N
2.5 A/6 A max. load)
Internal
resistance (Ω)
0.1
0.06
0.06
0.05
0.05
0.02
0.02
0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
www.e-t-a.com
Dielectric strength
(IEC 60664 and 60664A)
Interrupting capacity
Degree of protection
Shock
Corrosion
Humidity
For further details please see chapter: Technical Information
Voltage rating
Current rating range
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Insulation resistance
Interrupting capacity I
(UL 1077)
(IEC 60529/DIN 40050)
Vibration
Mass
Authority
VDE (EN 60934)
CSA/ UL
CCC
SEV
Technical data
Approvals
operating area
2-5000-...
0.05...16 A 5,000 operations at 2 x I
17...25 A
cn
Voltage ratings
AC 250 V; DC 28 V
AC 250 V; DC 50 V
AC 250 V
AC 250 V; DC 28 V
AC 250 V; DC 28 V
(UL: AC 250 V; DC 50 V)
0.05...25 A
AC 250 V / DC 28 V:
5,000 operations at 2 x I
-20...+60 °C (-4...+140 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
> 100 MΩ (DC 500 V)
0.05...2.5 A
3...5 A
6...12 A
13...25 A
I
0.05...20 A
0.05...25 A
(higher values upon request)
operating area IP40
terminal area IP00
8 g (57-500 Hz) ± 0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 29 g
N
8 x I
20 x I
200 A
(higher interrupting capacity
available to special order)
400 A
U
AC 250 V
DC 50 V
N
2-5700-...
N
Current ratings
0.05...25 A
0.05...20 A
0.05...25 A
0,05...25 A
N
pollution
degree
2
N
N
, inductive
, resistive
2,000 A
2,000 A
1 - 99
1

Related parts for 2-5700-IG1-K10-DD-20A

2-5700-IG1-K10-DD-20A Summary of contents

Page 1

... DD push to release/push to reset (type 2-5700 only) Current ratings 0.05...25 A 2-5700 - iG1 - P10 - .. - ordering example The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. Standard current ratings and typical internal resistance values ...

Page 2

... Thermal Overcurrent Circuit Breakers 2-5000/2-5700-... Dimensions 2-5000-P10 ø9.5 .374 19.8 .780 31 1.22 current rating 1.57 50 1.97 2-5700-P10 iG1 -27UNS-2A tightening torque max iG2=M12x1 tightening torque max. 1 19.8 .780 29 1.14 D-shaped threadneck current rating in A for standard (-DD version without push button marking) ...

Page 3

... Thermal Overcurrent Circuit Breakers 2-5000/2-5700-... Internal connection diagrams 0.05 ... 2 ... 25 A (with or without shunt terminal) (without shunt terminal) 1 (3) (-A3) 2 Typical time/current characteristics at +23 °C/+73.4 °F 10000 1000 100 ... times rated current The time/current characteristic curve depends on the ambient temperature prevailing ...

Page 4

... Thermal Overcurrent Circuit Breakers 2-5000/2-5700-... Accessories for types 2-5000 and 2-5700 with screw terminals -K10 Bus bar Y 303 563 01 7 .276 1 Accessories for type 2-5000-... Water splash cover, transparent for push button (IP64) Y 300 728 01 31.5 14.5 1.24 .571 4.5 18 .177 ...

Related keywords