722-0002 Redington Counters, Inc., 722-0002 Datasheet

no-image

722-0002

Manufacturer Part Number
722-0002
Description
Hour Meter, Flush-Rectangular, 90-240VAC 50/60Hz, 6 figure, Hours & 1/10s
Manufacturer
Redington Counters, Inc.
Type
Hourr
Datasheet

Specifications of 722-0002

Accuracy
±0.02% %
Cut Out, Panel
1.45×0.95 "
Digit Height
0.3
Dimensions
3.19"L×1.6"W×1.08"H
Display Digit Height
0.125 "
Display Type
Digital
Function
Hour
Material, Casing
Black Polymer
Number Of Digits
6
Primary Type
Electromechanical
Range, Measurement
0 to 99999.9 hrs.
Special Features
totally sealed
Temperature, Operating
40 to +185 (–40 to +85) °F (°C)
Voltage, Supply
90 to 240 VAC
Operating Temperature Range
–40°F to +185°F (–40°C to +85°C)
Electrical Termination
0.250" Spades
Weight
1.5 Oz.
Lead Free Status / Rohs Status
RoHS Compliant part
Specifications
Item # 722-0002 VAC, Clip Flush Rectangular
Model No.
Mounting
Reset
Termination
Display
Display Height
Display Height
No. of Digits
Records
Accuracy
Input Voltage
Power
Operating Temperature
Operating Temperature
Case Material
Weight
Weight
722
Clip Flush-Rectangular
Non-reset
1/4 inch (6.3mm) spade terminals
6 - digits, 0.125 inch (3.2mm) 99999.9
Hours - white on black
Tenths - red on white
0.125 Inch
3.2 mm
6
99999.9 hours
± 0.02 over entire range
90-240 VAC 50-60 Hz ± 10%
Less than 0.6 watts
-40 to +185 °F
-40 to +85 °C
Black Polymer
2 oz
57 gm
VAC, Clip Flush Rectangular
The Redington Model 722 provides an AC Hour Meter with an operating
range of 90-264VAC 50/60 Hz. You no longer require two separate meters,
one for 115VAC and one for 230VAC. Models are available in the standard
industry housings. Its quartz time base insures accurate long-term time
keeping. The Totally Sealed case protects against the environment and
provides years of reliable service. All applicable models are NEMA 4X,12
rated when mounted with optional gasket.
1

Related parts for 722-0002

722-0002 Summary of contents

Page 1

... Item # 722-0002 VAC, Clip Flush Rectangular VAC, Clip Flush Rectangular The Redington Model 722 provides an AC Hour Meter with an operating range of 90-264VAC 50/60 Hz. You no longer require two separate meters, one for 115VAC and one for 230VAC. Models are available in the standard industry housings ...

Page 2

Panel Cutout 1.45 x 0.95 Inch Panel Cutout 36.8 x 24.1 mm Approvals UL/CSA Recognized, CE Compliant Environmental Protection Totally sealed Vibration 10-75 Hz Stock Availability Yes Max. Panel Thickness 0.03 to 0.63 Inch Max. Panel Thickness 0.76 to 16.00 ...

Page 3

... Round, 90-264VAC 50/60Hz, ¼” [6.3mm] spade terminals, hours & 1/10’s 5003-009 NEMA 4X, 12 Gasket for Model 722-0002 5003-010 NEMA 4X, 12 Gasket for Model 722-0001 5003-011 NEMA 4X, 12 Gasket for Model 722-0004 ...

Page 4

... Model 722 Dimensions 2-Hole .7 [18] 2.19 [55.6] 1.89 [48.0] MAX MAX .10 [2.5] 2.05 [52.1] 1.47 [37.4] 2X Ø.15 [Ø3.8] 1.03 [26.2] .93 [23.5] 1/10 .15 [3.8] 1.75 [44.5] Panel Opening: 1.45” X 0.95” [36.8 X 24.1] Flush-Round .7 [18] 2.17 [55.1] 1.87 [47.5] MAX MAX ...

Related keywords