DPM 750S-BL Lascar Electronics, DPM 750S-BL Datasheet - Page 4

no-image

DPM 750S-BL

Manufacturer Part Number
DPM 750S-BL
Description
Module; Voltmeter Meter Type; 200; LCD; 0.5 in.; 5 VDC (Typ.); 0 to degC
Manufacturer
Lascar Electronics
Type
Voltager
Datasheet

Specifications of DPM 750S-BL

Accuracy
±0.1% %
Cut Out, Panel
2.44×1.26 "
Digit Height
0.5
Dimensions
2.36"W×1.18"H
Display Digit Height
0.5 "
Display Type
LCD
Function
Voltage
Meter Type
Voltmeter
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
200 mVDC
Special Features
Graphics
Temperature, Operating
0 to +50 °C
Voltage, Input
200 mVDC
Voltage, Supply
5
Lead Free Status / Rohs Status
RoHS Compliant part
DPM 750S-BL
Specifications liable to change without prior warning
Measuring a single ended input voltage
referenced to a split supply, i.e. the input
voltage and the meter's power supply
share the same 0V rail. Ensure solder link
LCOM is open.
±200mV
±200mV
SCALING
Two resistors Ra and Rb
may be used to alter the
full scale reading (FSR) of
the meter - see table. The
meter will have to be re-
calibrated by adjusting the
calibration potentiometer
on the rear of the module.
APPLICATIONS
Do not connect more than one meter to the same power supply if the meters cannot use the same signal
ground. Taking any input beyond the power supply rails will damage the meter.
3.0 to 7.5V Meter Power Supply
Measuring a single ended input voltage
referenced to supply, i.e. the input
voltage and the meter's power supply
share the same 0V rail. Ensure solder
link LCOM is open.
6.0 to 15.0V Meter Power
+3.0 to +7.5V
+3.0 to +7.5V
+
+
-3.0 to -7.5V
-
-
5
5
4
4
INHI
INHI
INLO
INLO
GND
V+
V+
V-
1
2
1
9
BL-
BL-
3
3
S
R
S
R =
BL
BL
BL
BL
*Ensure that Ra is rated for high voltage use.
0V
=
Voltage
Current
V+ - V- - 5V
V+ - 5V
Vin
I
30mA
in
±200mV
±200mV
30mA
+6.0 to +15.0V
Measuring an input voltage referenced to a
floating supply, i.e. the input voltage and the
meter's power supply are isolated from each
other. Ensure solder link LCOM is closed.
Measuring an input voltage referenced to a
floating supply, i.e. the input voltage and
the meter's power supply are isolated from
each other. Ensure solder link LCOM is
closed.
+3.0 to +7.5V
+
+
-
-
DPM 750S-BL
2000V*
200mA
200 A
20mA
200V
2mA
20V
FSR
2V
m
5
4
4
5
INHI
INLO
INHI
INLO
910k
1M
1M
1M
0R
0R
0R
0R
Ra
GND
V+
V+
V-
1
2
1
9
Issue 4
BL-
BL-
100R
100R
100k
10k
10R
Rb
1R
1k
1k
3
3
3½ Digit Backlit LCD Voltmeter Module
April/2008
S
R
S
R
BL
BL
BL
BL
0V
0V
=
=
V+ - 5V
V+ - 5V
30mA
30mA
Vin or in
+6.0 to +15.0V
+3.0 to +7.5V
I
I-
+
I
I-
Measuring a current from a circuit which is
floating with respect to the DPM's supply,
i.e. the current and the meter's power
supply are isolated from each other. Ensure
solder link LCOM is closed.
Measuring a current from a circuit which is
floating with respect to the DPM's supply,
i.e. the current and the meter's power
supply are isolated from each other. Ensure
solder link LCOM is closed.
+
+
-
S.C.
Rb
I
Rb
Ra
Applies to DPM 750S-BL/2
4
5
5
4
No.: 695 - Page 4 of 4
INHI
INLO
INHI
INLO
Rb
GND
V+
5
4
V+
1
2
V-
1
9
INHI
INLO
BL-
BL-
3
3
R
R
S
BL
BL
R
Page 4 of 4
Page 4 of 4
BL
S
BL
0V
=
=
BL
0V
V+ - 5V
V+ - 5V
30mA
30mA

Related parts for DPM 750S-BL