LAD9R1V TELEMECANIQUE, LAD9R1V Datasheet - Page 6

no-image

LAD9R1V

Manufacturer Part Number
LAD9R1V
Description
CONTACTOR, ACCESSORY, REVERSING KIT, INCL. MECHANICAL INTERLOCKS AND CONNECTORS
Manufacturer
TELEMECANIQUE
Datasheets

Specifications of LAD9R1V

Contact Form
2 NC
Function
Contactor
Primary Type
Contactor
Relay Type
Electro Mechanical
Accessory Type
Mechanical Interlock Kit
Approval Bodies
CSA, UL
Insulation Voltage
690V
Standard
EN60947 - 1
For Use With
TeSys Contactors
Linked contacts conforming to
draft standard IEC 947-4-5
Mirror contact
Rated operational voltage (Ue)
Rated insulation voltage (Ui)
Conventional thermal current (Ith)
Operating current frequency
Minimum switching capacity
Short-circuit protection
Rated making capacity
Short-time rating
Insulation resistance
Non-overlap time
Contact operating power
conforming to EN 60947-5-1
1 million operating cycles
3 million operating cycles
10 million operating cycles
AC-15
Contactor integral auxiliary contact characteristics
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
= 10
1
8
7
6
5
4
3
2
1
0,1
–8
Characteristics
Selection:
pages 1/6 to 1/35
Schneider Electric
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
References:
pages 2/6 to 2/9
1
(continued)
a.c. supply categories AC-14 and AC-15
Electrical life (valid for up to 3600 operating cycles/hour)
on an inductive load such as the coil of an electromagnet:
making power (cos
(cos
V
VA
VA
VA
Each contactor has 2 N/O and N/C contacts mechanically linked on the same movable contact holder
The N/C contact on each contactor represents the state of the power contacts and can be connected to a
PREVENTA safety module
Up to
Conforming to IEC 947-1
Conforming to UL, CSA
For ambient temperature
U min.
I min.
Conforming to EN 60947-5-1
Conforming to EN 60947-5-1, I rms
Permissible for
Guaranteed between N/C and N/O contacts
0.4).
24
60
16
4
2
48
120
32
8
3
Current broken in A
4
115
280
80
20
0.7) = 10 times the power broken
5
6
230
560
160
40
7
TeSys contactors
Model d
60 °C
1 s
500 ms
100 ms
Dimensions:
pages 2/44 to 2/47
8
9
10
400
960
280
70
440
1050
300
80
DC-13
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
1
8
7
6
5
4
3
2
1
0,1
440 V
600
1440
420
100
0,2
250 V
V
V
V
A
Hz
V
mA
A
A
A
A
M
ms
d.c. supply category DC-13
on an inductive load such as the coil of an electromagnet,
without economy resistor, the time constant increasing
with the load.
V
W
W
W
Schemes:
pages 2/48 and 2/49
Electrical life (valid for up to 1200 operating cycles/hour)
0,3
125 V
24
96
48
14
0,4
690
690
600
10
25…400
17
5
gG fuse: 10 A
": 140, $: 250
100
120
140
> 10
1.5 on energisation and on de-energisation
0,5
0,6
48
76
38
12
48 V
0,7
0,8
0,9
1
125
76
38
12
24 V
250
76
32
2
440
44
3
Current broken in A
4
5
6
7
2/37
8
9
10
2

Related parts for LAD9R1V