SR103AM02 Sti (Scientific Technologies, Inc.), SR103AM02 Datasheet

no-image

SR103AM02

Manufacturer Part Number
SR103AM02
Description
Relay; SSR; Sfty; 2 NC, 3 NO, 1 NC; Cur-Rtg 3A; Ctrl-V 115AC; Vol-Rtg 230AC
Manufacturer
Sti (Scientific Technologies, Inc.)
Datasheet

Specifications of SR103AM02

Contact Form
3PDT, SPST-NC
Current, Rating
3 A
Function
Safety
Mounting Type
DIN Rail
Relay Type
Solid State
Standards
cULus, UL, CE, VDE
Voltage, Control
115 VAC
Voltage, Rating
230 VAC
H
SR103AM
SR103AM
Dual Channel Safety Monitoring Relay
Power requirements—the
SR103AM will accept
24 VAC/DC, 115 VAC, or
230 VAC
Inputs—the SR103AM will ac-
cept single or dual N/C inputs or
dual inputs from a light curtain
(see SR102AM for application
wiring for a light curtain)
Outputs—the SR103AM has
3 N/O outputs to route power
to the coils of power contactors,
plus 1 N/C auxiliary output for
signaling purposes
External Device Monitoring
(EDM) is provided with a N/C
loop between S11/S12 and S21
on the SR103AM
Conforms to EN60204-1, EN954-1, VDE 0113-1
UL and C-UL listed, BG approved
Monitored manual or auto-
matic/manual reset modes are
available on the SR103AM.
Monitored manual reset re-
quires closure of the reset circuit
followed by opening of the cir-
cuit. Reset occurs when circuit
is opened. Auto reset requires
only closure of the reset circuit
as reset occurs when circuit is
closed.
C
R
US

Related parts for SR103AM02

SR103AM02 Summary of contents

Page 1

SR103AM H SR103AM Dual Channel Safety Monitoring Relay Power requirements—the ■ SR103AM will accept 24 VAC/DC, 115 VAC, or 230 VAC Inputs—the SR103AM will ac- ■ cept single or dual N/C inputs or dual inputs from a light curtain (see ...

Page 2

Application ■ 24VAC/DC, 110VAC, 230VAC EB SERIES LATCHING E-STOP BUTTON GUARD A1 CLOSED Power supply (S11 = T5009 INTERLOCK SWITCH A2 ✎ For a full explanation of the circuit operating principle and ...

Page 3

SR103AM Block Diagram ■ A1 S11 S21 S12 relay control and Power supply fault monitoring (S11=24V Pin assignment S10 S13 H Dimensions — mm/in. ■ Sr103Am ...

Page 4

... EN 60204-1, EN 954-1, VDE 0113-1 CE marked for all applicable directives, UL and C-UL, BG Cat. 4 per EN954-1 (SR103 internal operation) inputs Outputs 2 N/C 3 N/O 2 N/C 3 N/O 2 N/C 3 N/O SR103AM Sr103Am02 Sr103Am03 115 VAC 230 VAC Auxiliary Part no. 1 N/C 44510-1031 1 N/C 44510-1032 1 N/C 44510-1033 ...