E5CNR2MTD500ACDC24 Omron Automation, E5CNR2MTD500ACDC24 Datasheet - Page 7

no-image

E5CNR2MTD500ACDC24

Manufacturer Part Number
E5CNR2MTD500ACDC24
Description
Controller, Digital Temp, 48x48mm, Relay Out, Thermoc In, 24V AC/DC, 2 Aux Out
Manufacturer
Omron Automation
Type
Temperaturer
Datasheet

Specifications of E5CNR2MTD500ACDC24

Brand/series
E5CN Series
Communication
USB
Contact Form
SPST-NO
Dimensions
48mmW×48mmH×78mmD
Enclosure Rating
IP00, IP20, IP66
Input Type
RTD/Thermocouple
Ip Rating
IP00, IP20, IP66
Mounting Type
DIN Rail
Number Of Outputs
2
Output Type
Relay
Primary Type
Controller
Special Features
USB Serial
Standards
UL, cULus, CSA
Termination
Terminal Block
Voltage, Supply
24 VAC/VDC
Supply Voltage
100-240 VAC or 24 VAC/VDC
Current Output
4-20 mA DC (E5CN-E5AN-E5EN)
Thermocouple Inputs
K, J, T, L, E, U, N, R, S, B
Platinum Rtd
Pt100 and JPt100
Infrared Sensor
10-70°C, 60-120°C, 115-165°C, 160-260°C
Voltage
0 to 50 mV
Lead Free Status / Rohs Status
RoHS Compliant part
Input Ranges
Thermocouple/Platinum Resistance Thermometer (Universal Inputs)
Shaded settings are the default settings.
The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990
Models with Analog Inputs
Shaded settings are the default settings.
Setting
number
Input specification
Setting range
Setting number
Name
Input
Type
−100.0
−200.0
2300
1800
1700
1600
1500
1400
1300
1200
1100
1000
Input Type
900
800
700
600
500
400
300
200
100
0
−200 −199.9
850
0
Platinum resistance
Pt100
500.0
thermometer
1
100.0
0.0
2
Usable in the following ranges by scaling:
−1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or −1.999 to 9.999
0
4 to 20mA
−199.9
500.0
JPt100
3
100.0
0.0
4
Current
1300
−200
5
1
0 to 20 mA
K
500.0
−20.0 −100 −20.0
6
850
7
J
400.0
2
8
1 to 5 V
−200 −199.9 −200
400
9
T
400.0
10
3
600
Voltage
11
0 to 5 V
E
Thermocouple
−100
850
12
L
JPt100: JIS C 1604-1989, JIS C 1606-1989
Pt100: JIS C 1604-1997, IEC 751
PL II: According to Platinel II electromotive force charts from BASF (previously
−200 −199.9 −200
400
13
4
U
0 to 10 V
400.0
Engelhard)
14
1300
15
N
1700 1700
16
R
0
17
S
0
1800
100
18
B
2300
24
W
0
1300
PL
25
II
0
10 to
70°C
E5CN/E5CN-U
Infrared temperature
19
90
0
60 to
120
120
20
°C
sensor
0
165
115
165
21
to
°C
0
140
260
260
22
°C
to
0
Usable
in the
following
ranges
by
scaling:
−1999 to
9999 or
−199.9
to 999.9
Analog
50 mV
input
0 to
23
9

Related parts for E5CNR2MTD500ACDC24