H7CXAWD1NDC1224AC24 Omron Automation, H7CXAWD1NDC1224AC24 Datasheet - Page 21

no-image

H7CXAWD1NDC1224AC24

Manufacturer Part Number
H7CXAWD1NDC1224AC24
Description
Counter; Digital; 12-24VDC 24VAC; Contact Output; 6; Screw Terminal; 50/60 Hz
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CXAWD1NDC1224AC24

Brand/series
H7CX
Connection Type
Screw Terminals
Contact Form
3 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Counter
Input Type
Increment, Decrement, Command, Individual and Quadrature
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
4
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Counter
Voltage, Supply
12-24 VDC/24 VAC
Input Modes and Present Value (See note 1.)
I/O Functions for Counter Operation
CP1: Count input; CP2: Prohibit (gate) input
CP1: Prohibit (gate) input; CP2: Count input
* Counting starts when the CP1 is turned ON after turning ON the power.
A
A
A
B
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
must be at least 1/2 the minimum signal width. (See note 2.)
Present value
Present value
Present value
Present value
*CP1
CP2
CP1
CP2
CP1
CP2
CP1
CP2
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
0
0
0
UP/DOWN C Quadrature Input Mode
UP/DOWN A Command Input Mode
0
B B B B
1
1
1
UP (Increment) Mode
1
2
2
2
3
3
A
Prohibit
2
A
A
2
Prohibit
2
3
1
1
A
3
A
A
4
2
2
4
5
3
3
5
CP1: Count input; CP2: Prohibit (gate) input
CP1: Prohibit (gate) input; CP2: Count input
Note: 1. If the configuration selection is set to dual counter, CP1 and
A
A
must be greater than the minimum signal width. (See note 2.)
must be greater than the minimum signal width. (See note 2.)
Present value
Present value
Present value
Symbol
Input method
2.
3. The meaning of the H and L symbols in the tables is explained
*CP1
CP2
CP1
CP2
CP1
CP2
CP2 input will operate in the same way as the count input
(CP1) of UP (increment) mode.
must be at least 1/2 the minimum signal width.
If they are less, a count error of 1 may occur.
Minimum signal width: 16.7 ms (when maximum counting speed = 30 Hz)
below.
A
H
L
must be greater than the minimum signal width and
H
L
H
L
0
H
L
H
L
0
H
L
H
L
0
n
0
n
UP/DOWN B Individual Input Mode
n 1
1
DOWN (Decrement) Mode
n 1
No-voltage input
n 2
2
(NPN input)
Short-circuit
100 s (when maximum counting speed = 5 kHz)
Open
3
A
n 2
Prohibit
2
A
Prohibit
n 3
1
H7CX-A@-N
Voltage input (PNP
1
4.5 to 30 VDC
A
n 3
0 to 2 VDC
input)
A
n 4
2
Counter
n 4
n 5
3
n 5
B
21