E2E-X10Y1-US Omron Automation, E2E-X10Y1-US Datasheet

no-image

E2E-X10Y1-US

Manufacturer Part Number
E2E-X10Y1-US
Description
Sensor; Inductive Sensing Mode; M30; 10 mm; 24 to 240 VAC; 1.7 mA (Max.); 25 Hz
Manufacturer
Omron Automation
Type
Inductiver
Datasheet

Specifications of E2E-X10Y1-US

Body Style
Cylindrical
Current, Supply
1.7 mA (Max.)
Current, Switching
300 mA
Frequency, Operating
50⁄60 Hz
Frequency, Switching
25 Hz
Function
Proximity
Indicator
Red LED (Operation Indicator)
Ip Rating
IP67
Mounting Type
M30 Threaded
Output
NO
Primary Type
Proximity
Range, Measurement
10 mm
Standards
UL Recognized, CSA Certified
Technology
Inductive
Temperature Range
-40 to +85 °C
Termination
Connector
Voltage, Supply
240 VAC
Voltage, Switching
3 V
Supply Voltage Range
10-30 VDC or 20-264 VAC, 50/60 Hz (Model Dependant)
Load Rating
100/200 mA (DC) or 5-100 mA/5-200 mA/5-300 mA (AC) (Model Dependant)
Approvals
CE, UL, CSA (Model Dependant)
Lead Free Status / Rohs Status
RoHS Compliant part
Standard Sensors for Detecting
Ferrous Metals under Standard
Conditions
■ Wide array of variations. Ideal for a variety of applications.
■ Lineup includes models with pre-wired connectors that use
■ Lineup includes models with 3-mm diameter and sensing
■ Cable protector provided as a standard feature.
■ Sensing surface made from material that resists cutting
Cylindrical Proximity Sensor Selection Guide
Determine the
size based on
the installation
space.
Standard Proximity Sensor
E2E
highly oil-resistant cables
distance of 0.6 mm
oil for superior environment resistance.
Size
Be sure to read Safety Precautions on
page 22.
Shield-
ing
Additions to the Series
Diameter Power supply
3 dia.
4 dia.
M5
5.4 dia.
M8
M12
M18
M30
M8
M12
M18
M30
Diameter
DC 3-wire
DC 3-wire
DC 3-wire
DC 3-wire
DC 3-wire
AC 2-wire
DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
AC/DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
AC/DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
AC/DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
0.6
0.8
1.0
1.5
2
Sensing distance
Sensing distance (mm)
3
4
5
7
The sensing distance depends on
the diameter, shielding, and type
of power supply.
8
10
14
18
20
1

Related parts for E2E-X10Y1-US

E2E-X10Y1-US Summary of contents

Page 1

... Standard Proximity Sensor E2E Additions to the Series Standard Sensors for Detecting Ferrous Metals under Standard Conditions ■ Wide array of variations. Ideal for a variety of applications. ■ Lineup includes models with pre-wired connectors that use highly oil-resistant cables ■ Lineup includes models with 3-mm diameter and sensing distance of 0.6 mm ■ ...

Page 2

... Connector Models E2E-X@D@-M1(G) E2E-X@E@-M1 E2E-X@Y@-M1 Pre-wired Connector Models E2E-X@D1-M1(G)J(-T) Smartclick Pre-wired Connector Models E2E-X@D@-M1TGJ-U Models with Highly Oil-resistant Cables E2E-X@D@-U Robotics Cable Models E2E-X@D1-R E2E-X@E1-R Models with a different frequency (NO Models only) E2E-X@@15 DC 2-Wire Models E2E-X@D@ DC 3-Wire Models E2E-X@E@ ...

Page 3

... Features Additions to the Series Proximity Sensors with Highly Oil-resistant Cables added to the lineup with the E2E-@-U Oil Resistance Oil Resistance Oil Resistance Oil Resistance (Insulation service life): twice or three times that of oil-resistant vinyl chloride Models with Smartclick pre-wired connectors added to the E2E-@-U Series ...

Page 4

... Models with robotics cables are also available. Add "-R" to the end of the model number (example: E2E-X4MD1-R). The model number E2E-X2D1-N, however, becomes E2E-X2D1-R. *3. Models are also available with 5-m cables. Add the cable length to the model number (example: E2E-X3D1-N 5M). DC 2-Wire, Connector Models (Models with self-diagnostic function are 3-wire.) ...

Page 5

... The standard cable length is 300 mm. Models are also available with 500 mm and 1 m cables. * Refer to page 19 for details. Connector Pin Assignments of DC 2-Wire Models • The connector pin assignments of each New E2E DC 2-Wire Model conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have been changed in comparison to the previous models.) • ...

Page 6

... Models with robotics cables are also available. The model numbers are E2E-X @E1-R (example: E2E-X5E1-R). *3. Models with different frequencies are also available. The model numbers are E2E-X @E@5 (example: E2E-X5E15). *4. These models are also available with e-CON connectors (0.3-m cable). Add "-ECON" to the end of the model number (example: E2E-X2E1-ECON). DC 3-Wire, Connector Models ...

Page 7

... M18 M30 *1. Models with different frequencies are also available. The model numbers are E2E-X @Y@5 (example: E2E-X5Y15). *2. Models are also available with 5-m cables. Add the cable length to the model number (example: E2E-X2Y1 5M). AC 2-wire, Connector Models Connec- Appearance Sensing distance ...

Page 8

... Accessories Instruction manual *1. Use the E2E within the range in which the setting indicator (green LED (except D2 Models). *2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. ...

Page 9

... E2E-X@E@/F@ DC 3-Wire Models Size M8 Shielded Shielded Unshielded Model E2E E2E Item -X1R5E@/F@ -X2ME@/F@ 1.5 mm ±10 ±10% Sensing distance Set distance 1.6 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 13 and 14.) ...

Page 10

... E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models Size 3 dia. Shielded Item Model E2E-CR6C/B@ 0.6 mm ±15% Sensing distance Set distance 0 to 0.4 mm Differential travel 15% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 14.) Iron, 3 × 3 × ...

Page 11

... E2E-X@Y@ AC 2-Wire Models Size M8 Shielded Shielded Unshielded Item Model E2E-X1R5Y@ E2E-X2MY@ 1.5 mm ±10 ±10% Sensing distance Set distance 1.6 mm Differential travel 10% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 14.) ...

Page 12

... Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset. M12 M18 Shielded E2E-X3T1 E2E-X7T1 7 mm ±10 5.6 mm Iron, 18 × 18 × 0.5 kHz 2 10 times each and Z directions Approx. 140 g E2E M30 E2E-X10T1 10 mm ±10 Iron, 30 × 30 × 0.4 kHz Approx. 190 g 12 ...

Page 13

... Polarity: None 4 Load +V Prox imity Sensor main circuit (+V) Note 1. The load can be connected to either the + side. 2. The E2E-X@D1-M1J-T has no polarity. Therefore, terminals 3 and 4 have no polarity. 1 Load +V Brown Prox- imity Sensor main circuit Blue Note: The load can be connected to either the + side. ...

Page 14

... E2E-X@D1-M1J-T 3 E2E-X@E/F1-M1 9 E2E-X@D1-M1 2 E2E-X@D2-M1 7 E2E-X@D2-M1(G) 6 E2E-X@D1S-M1 5 E2E-X@Y1-M1 11 E2E-X@Y2-M1 12 E2E-X@D1-M1G 1 E2E-X@D1-M1GJ E2E-X@D1-M1J-T 3 E2E-X@E/F1-M1 9 E2E-X@D1-M1 2 E2E-X@D2-M1 7 E2E-X@D2-M1(G) 6 E2E-X@D1S-M1 5 E2E-X@Y1-M1 11 E2E-X@D1-M1G 1 E2E-X@D1-M1GJ E2E-X@D1-M1J-T 3 E2E-X@E/F1-M1 9 E2E-X@D1-M1 2 E2E-X@D2-M1 7 E2E-X@D2-M1(G) 6 E2E-X@D1S-M1 5 E2E-X@Y1-M1 11 E2E-X@D@-M1TGJ-U 13, 14 E2E-X@D1-M3G 4 E2E-X@D2-M3G 8 E2E-X@E/F1-M3 10 E2E-X@D1-M3G 4 E2E-X@D2-M3G 8 E2E-X@E/F1-M3 10 E2E-X@D1-M3G 4 E2E-X@D2-M3G 8 E2E-X@E/F1-M3 10 E2E-X@D1-M3G 4 E2E-X@D2-M3G 8 E2E-X@E/F1- ...

Page 15

... G: 5-m cable 1: Straight E2E 2: L-shape XS2F-D42@-@C0-A D: 2-m cable G: 5-m cable 1: Straight E2E 2: L-shape XS3F-M42@-40@-R 2: 2-m cable 5: 5-m cable 1: Straight E2E 2: L-shape XS2F-D42@-@80-A D: 2-m cable G: 5-m cable 1: Straight E2E 2: L-shape XS2F-D42@-@80-A D: 2-m cable G: 5-m cable 1: Straight E2E 2: L-shape ...

Page 16

... XS3F-M42@-40@-R 2: 2-m cable 5: 5-m cable 1: Straight E2E 2: L-shape XS2F-A42@-@B0-A D: 2-m cable G: 5-m cable E2E XS2F-A421-@90-A D: 2-m cable G: 5-m cable E2E-X @ -M1TGJ XS5F-D421-@80-P D: 2-m cable G: 5-m cable E2E-X @ -M1TGJ XS5F-D421-@80-P D: 2-m cable G: 5-m cable E2E Connections XS2F 1 1 ...

Page 17

... The cable can be extended up to 200 m (separate metal conduit). *2. D Models: Operation indicator (red) and setting indicator (green), E/F Models: Operation indicator (red) Diagram 8 E2E-X2MY@ 15 dia 6.1 dia × Insulator Diagram 10 E2E-X8MD@ 5.9 E2E-X5ME@/ dia. 15.6 Connector: Product code 17 37104-3163-000FL (Sumitomo 3M dia ...

Page 18

... Insulator diameter: 1.9 mm), Standard length The cable can be extended (separate metal conduit 200 m for the control output and up to 100 m for the diagnostic output. *2. D/T Models: Operation indicator (red), Setting indicator (green) E/F/Y Models: Operation indicator (red) Diagram 12 E2E-X5MY@ 21 dia dia. ...

Page 19

... The cable can be extended (separate metal conduit 200 m for the control output and up to 100 m for the diagnostic output. *2. D/T Models: Operation indicator (red), Setting indicator (green) E/F/Y Models: Operation indicator (red) M8 Connector Models (Unshielded) Diagram 29 E2E-X4MD@-M3G/E2E-X2ME1-M3/F@ 15 dia Models: Operation indicator 6.1 dia. ...

Page 20

... Diagram 20 E2E-X3D@-M1(G) E2E-X2E1-M1/ dia Indicators * M12 × 1 Two clamping nuts Toothed washer * D Models: Operation indicator (red), Setting indicator (green) E/F Models: Operation indicator (red) Diagram 22 E2E-X2Y@- dia M12 × 1 Two clamping nuts Toothed washer Diagram 24 E2E-X7D@-M1(G)/E2E-X5E1-M1 E2E-X5Y@- dia ...

Page 21

... Pre-wired Connector Models (Shielded) Diagram 30 E2E-X2D1-M1TGJ-U *3 Diagram 31 E2E-X3D1-M1GJ E2E-X3D1-M1J-T E2E-X3D1-M1TGJ-U *3 Diagram 33 E2E-X7D1-M1GJ E2E-X7D1-M1J-T E2E-X7D1-M1TGJ-U *3 Diagram 35 E2E-X10D1-M1GJ E2E-X10D1-M1J-T E2E-X10D1-M1TGJ-U *3 Pre-wired Connector Models (Unshielded) Diagram 32 E2E-X8MD1-M1GJ Mounting Hole Dimensions Dimension F (mm dia Indicators *2 M8 × 1 Two clamping nuts Toothed washer dia Indicators *2 M12 × 1 ...

Page 22

... Diagram 34 E2E-X14MD1-M1GJ Diagram 36 E2E-X20MD1-M1GJ Dimensions for Proximity Sensors with Sensor I/O Connectors Shielded Models Unshielded Models Straight Connectors Straight Connectors L1 L-shape Connectors L-shape Connectors L2 Accessories (Order Separately) Sensor I/O Connectors Refer to Introduction to Sensor I/O Connectors for details. Mounting Brackets Protective Covers Sputter Protective Covers Refer to Y92@ for details ...