M165-TY-24D Omron Automation, M165-TY-24D Datasheet - Page 7

no-image

M165-TY-24D

Manufacturer Part Number
M165-TY-24D
Description
Switch, Pilot light; Yellow; 16mm; 24VDC; Panel; Solder; 0.5 to 3.2mm; 37.8mm; 18mm
Manufacturer
Omron Automation
Type
LEDr
Datasheet

Specifications of M165-TY-24D

Color, Lens
Yellow
Lamp Type
LED
Lens Color
Yellow
Lens Style
Round
Mount Method
Screw
Mounting Hole Size
16 mm
Mounting Size
16 mm
Mounting Type
Screw
Primary Type
Pilot Light
Special Features
Oil Resistant
Termination
Solder
Voltage, Operating
24 VAC/VDC
Voltage, Supply
24 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M165-TY-24D
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Dimensions
Terminal Arrangement
Accessories, Replacements, and Tools
The accessories, replacements, and tools are also used with the A16 Pushbutton Switch. Refer to the A16 datasheet.
Safety Precautions
Mounting
Application
Screw-less Clamps
Mounting Procedure
1. Strip a length of 10 mm off the end of the wire (allowable range:
2. Bunch wire strands together and straighten them.
3. Insert the wire into the insertion hole while pressing the release
4. Let go of the release button to lock the wire into place.
5. After locking, pull on the wire gently to confirm that it is securely
• When mounting the Case onto the Socket Unit, ensure that the
orientation is correct. Perform mounting with the dimple on the
Case and the TOP mark on the Socket Unit facing in the same
direction.
10±1 mm).
button at the side of the hole. (Using a precision screwdriver is
recommended.)
locked.
The L+ is not shown on the Socket Unit.
Case
Solder Terminals
(BOTTOM VIEW)
L +
L -
dimple
Socket Unit
TOP mark
+
+
-
Screw-less Clamp
Black
Red
Side with TOP indicated
Wiring
Removing Procedure
1. Remove wires by pulling them while pressing the release button.
Note: When reusing wires that have already been locked, cut off the end of the
• When using stranded wire, gather the ends of the strands together
• When wiring, insert the wire until it comes into contact with
• After wiring, ensure that continuous pressure is not applied to the
• Refer to internal connections diagrams and confirm the terminal
(BOTTOM VIEW)
before wiring.
something. After wiring is completed, pull on the wires to confirm
that they are connected securely.
terminals.
numbers before performing wiring.
wire and strip the wire again before using.
(All units are in millimeters unless otherwise indicated.)
-
+
+
Models with voltage-reduction lighting have a
circuit to reduce voltage built in.
Voltage-reduction Lighting
Side with TOP indicated
(BOTTOM VIEW)
-
+
+
M16
11