H3CR-H8L-AC100/120M Omron Automation, H3CR-H8L-AC100/120M Datasheet

no-image

H3CR-H8L-AC100/120M

Manufacturer Part Number
H3CR-H8L-AC100/120M
Description
Timer, Power-Off Delay, Analog-Set, 0.05 Sec to 12 Min, 100 to 120 VAC
Manufacturer
Omron Automation
Datasheet

Specifications of H3CR-H8L-AC100/120M

Lead Free Status / Rohs Status
RoHS Compliant part
DIN 48 × 48-mm Power OFF-delay Timer
• Long power OFF-delay times;
• Models with forced-reset input are available.
• 11-pin and 8-pin models are available.
Model Number Structure
■ Model Number Legend
Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 1 for
■ List of Models
1. Classification
H:
2. Configuration
None: 11-pin socket
8:
Note: Specify the model number, supply voltage, and time range (S or M) when ordering.
Without
reset
input
With
reset
input
H3CR - H @ @ L @ @
S-series: up to 12 seconds,
M-series: up to 12 minutes.
Input Output Supply voltage
Solid-state Power OFF-delay Timers
H3CR-H
availability.
Example: H3CR-H8L 100-120AC S
Power OFF-delay timer
8-pin socket
DPDT
SPDT
1 2
100 to 120 VAC ---
200 to 240 VAC
24 VAC/DC
48 VDC
100 to 125 VDC
100 to 120 VAC H3CR-HRL 100-120AC S ---
200 to 240 VAC H3CR-HRL 200-240AC S
24 VAC/DC
48 VDC
100 to 125 VDC H3CR-HRL 100-125DC S
100 to 120 VAC ---
200 to 240 VAC
24 VAC/DC
48 VDC
100 to 125 VDC
3 4 5
6
H3CR-HRL 24AC/DC S
H3CR-HRL 48DC S
Note: Specify the model number, supply voltage, and time range (S or M) when ordering.
11-pin models
3. Input
None: Without reset input
R:
4. Dimensions
L:
Supply voltage
Time range
With reset input
Long-body model
S-series
H3CR-H8L 100-120AC S
H3CR-H8L 200-240AC S
H3CR-H8L 24AC/DC S
H3CR-H8L 48DC S
H3CR-H8L 100-125DC S
H3CR-H8RL 100-120AC S ---
H3CR-H8RL 200-240AC S
H3CR-H8RL 24AC/DC S
H3CR-H8RL 48DC S
H3CR-H8RL 100-125DC S
8-pin models
5. Supply Voltage
100-120AC: 100 to 120 VAC
200-240AC: 200 to 240 VAC
48DC:
100-125DC: 100 to 125 VDC
48 VDC
---
H3CR-HRL 100-120AC M ---
H3CR-HRL 200-240AC M
H3CR-HRL 24AC/DC M
H3CR-HRL 48DC M
H3CR-HRL 100-125DC M
11-pin models
M-series
6. Time Range
S:
M:
H3CR-H8L 100-120AC M
H3CR-H8L 200-240AC M
H3CR-H8L 24AC/DC M
H3CR-H8L 48DC M
H3CR-H8L 100-125DC M
H3CR-H8RL 100-120AC M
H3CR-H8RL 200-240AC M
H3CR-H8RL 24AC/DC M
H3CR-H8RL 48DC M
H3CR-H8RL 100-125DC M
CSM_H3CR-H_DS_E_1_4
0.05 to 12 s
0.05 to 12 min
8-pin models
1

Related parts for H3CR-H8L-AC100/120M

H3CR-H8L-AC100/120M Summary of contents

Page 1

... Model Number Structure ■ Model Number Legend Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 1 for availability. H3CR - Note: Specify the model number, supply voltage, and time range ( when ordering ...

Page 2

... Note the above minimum power ON time is not secured, the H3CR may not operate. Be sure to secure the above minimum power ON time not use the Timer with a repeat period of less than 3 s. Doing so may result in abnormal heating or burning. Refer to Safety Precautions (H3CR-H) on page 8 for details ...

Page 3

... EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: IEC61000-4-4: IEC61000-4-5: H3CR contact discharge (level air discharge (level 3) IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level (0. MHz) (level power-line (level I/O signal-line (level line to line (level line to ground (level 3) ...

Page 4

... Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ and a maximum current of 0.1 A can be switched if L ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load VDC for H3CR-H8L/-HRL and 100 VDC for H3CR-H8RL (failure level: P). Time range/ ...

Page 5

... Without Reset Input (H3CR-H8L) Power supply 11-pin Model With Reset Input (H3CR-HRL) Reset input Power supply Note: Leave terminal 6 open. Do not use them as relay terminals. With Reset Input (H3CR-H8RL) Reset input Power supply Note: Leave terminal 3 open. Do not use them as relay terminals. H3CR-H 5 ...

Page 6

... ON (Short-circuited) Reset input OFF (Open) Output (8 − 6) Output (8 − 5) Lit Output indicator Not lit Rt ON Power OFF (See note) 0.05 s min. Reset input Output (1 − 3) Output (1 − 4) Output (11 − 9) Output (11 − 8) Lit Output indicator Not lit H3CR 0.05 s min 0.05 s min. 6 ...

Page 7

... Dimensions with Back Connecting Socket P3G-08/P3GA-11 92.9 15 86.4 H3CR-HRL 109.9 H3CR- H8@L P3G-08 Y92F-30 * P2CF-11 2.3 P2CF-11-E H3CR-H Time setting knob (for setting power OFF-delay time) 78.0 0.7 44.8 × 44.8 8 pins 78.0 0.7 44.8 × 44.8 11 pins 92 ...

Page 8

... Power Reset input Output required that the output be turned on repeatedly with an interval of shorter than 3 s, consider use of the H3CR-A in mode D (signal OFF-delay). ■ Others If the H3CR-H is dropped or experiences some other kind of shock, because a latching relay is used for output, contacts may be reversed or go into a neutral state ...

Page 9

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a ...

Related keywords