E2E-X10ME1 Omron Automation, E2E-X10ME1 Datasheet - Page 12

no-image

E2E-X10ME1

Manufacturer Part Number
E2E-X10ME1
Description
Sensor, Proximity; Inductive Sensing Mode; M18; NPN; 10 mm; -40 to degC
Manufacturer
Omron Automation
Type
Inductiver
Datasheet

Specifications of E2E-X10ME1

Body Style
Cylindrical
Current, Switching
200 mA
Function
Proximity
Ip Rating
IP67
Mounting Type
M18 Threaded
Output
NPN
Primary Type
Proximity
Range, Measurement
10 mm
Standards
IEC Approved, NEMA Approved
Technology
Inductive
Temperature, Operating
-40 to +85 °C
Termination
Pre-Wired
Vibration
10 to 55 Hz
Voltage, Supply
24 VDC
Voltage, Switching
2 V
Lead Free Status / Rohs Status
RoHS Compliant part
AC/DC 2-Wire Models
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
*2. Power Supply Voltage Waveform:
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing object
Response
frequency *1
Power supply voltage
(operating voltage range) *2
Leakage current
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Protection circuits
Ambient temperature range Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity range
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
a set distance of half the sensing distance.
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
DC
AC
Load
current
Residual
voltage
Case
Sensing
surface
Clamping
nuts
Toothed
washer
Shielded
Model
Size
3 mm ±10%
0 to 2.4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 13.)
Iron, 12 × 12 × 1 mm
1 kHz
25 Hz
24 to 240 VDC (20 to 264 VDC)
48 to 240 VAC (40 to 264 VAC)
DC: 1 mA max.
AC: 2 mA max.
5 to 100 mA
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
Operation indicator (red), Setting indicator (green)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 16 for details.)
Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Operating/Storage: 35% to 95%
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 1,000 m/s
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Approx. 80 g
Nickel-plated brass
PBT
Nickel-plated brass
Zinc-plated iron
Instruction manual
E2E-X3T1
M12
2
10 times each in X, Y, and Z directions
7 mm ±10%
0 to 5.6 mm
Iron, 18 × 18 × 1 mm
0.5 kHz
Approx. 140 g
E2E-X7T1
Shielded
M18
10 mm ±10%
0 to 8 mm
Iron, 30 × 30 × 1 mm
0.4 kHz
Approx. 190 g
E2E-X10T1
M30
E2E
12