MY4Z-AC110/120(S) Omron Automation, MY4Z-AC110/120(S) Datasheet - Page 3

no-image

MY4Z-AC110/120(S)

Manufacturer Part Number
MY4Z-AC110/120(S)
Description
RELAY, PLUG IN, 4PDT, 120VAC, RATED LOAD 3A, QUICK CONNECT TERMINALS
Manufacturer
Omron Automation
Datasheet

Specifications of MY4Z-AC110/120(S)

Lead Free Status / Rohs Status
RoHS Compliant part
■ Characteristics
Note: The values given above are initial values.
■ Life Expectancy Characteristics
■ Approved Standards
VDE, UL, CSA, IMQ, CE
■ Precautions
Connections
Do not reverse polarity when connecting DC-operated Relays with
built-in diodes or indicators or high-sensitivity DC-operated Relays.
Mounting
Whenever possible, mount Relays so that it is not subject to vibration
or shock in the same direction as that of contact movement.
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric withstand voltage
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Weight
Pole
2-pole
4-pole
4-pole (bifurcated)
Mechanical life
(at 18,000 operations/hr)
AC:50,000,000 operations min.
DC:100,000,000 operations min.
20,000,000 operations min.
Mechanical 18,000 operations/hr
Electrical
Operating
Operating
100 mΩ max.
20 ms max.
20 ms max.
1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)
Destruction:10 to 55 Hz, 1.0 mm double amplitude
Malfunction:10 to 55 Hz, 1.0 mm double amplitude
Destruction:1,000 m/s
Malfunction:200 m/s
See the following table.
-55°C to 70°C (-67°F to 158°F) with no icing (see note)
5% to 85% RH
Approx. 35 g
2
(approx. 20G)
2
(approx. 100G)
Electrical life
(at 1,800 operations/hr under rated load)
500,000 operations min.
200,000 operations min.
100,000 operations min.
General-purpose Relay
MY
261

Related parts for MY4Z-AC110/120(S)