H7ER-NV-B Omron Automation, H7ER-NV-B Datasheet - Page 4

no-image

H7ER-NV-B

Manufacturer Part Number
H7ER-NV-B
Description
Tachometer; Self-Powered; 24 VDC; Digital; LCD; 4; Screw Terminal; 1 kHz; Count
Manufacturer
Omron Automation
Type
Tachometerr
Datasheet

Specifications of H7ER-NV-B

Color, Case
Black
Connection Type
Screw
Counter Type
Self-Powered
Cut Out, Panel
45×22.2 mm
Dielectric Rating
1,000 VAC, 50⁄60 Hz for 1
Digit Height
8.6
Dimensions
48.5mmL×48mmW×35mmH
Display Digit Height
8.6 mm
Display Type
LCD
Frequency, Operating
1 kHz
Function
Tachometer
Input Type
Count
Memory Type
Lithium Battery
Mounting Type
Panel
Number Of Digits
7
Output Type
Digital
Primary Type
Electronic
Range, Measurement
1000 s-1 (1 pulse/rev.), 1000 min-1 (60 pulse/rev.)
Resistance, Insulation
100 M≠ (Min.) @ 500 VDC
Signal, Input
NPN/PNP DC Voltage
Standards
UL Listed, CSA Certified
Temperature, Operating, Range
-10 to +55 °C
Terminal Type
Screw Terminal
Termination
Screw Terminal
Voltage, Supply
24 VDC
Weight
65 g
4-digit Tachometer
1000 RPS (1 Pulse/Rev.), 1000 RPM (60 Pulse/Rev.)
Lead Free Status / Rohs Status
RoHS Compliant part
■ Characteristics
Note: Weight includes waterproof packing and flush mounting bracket.
■ Reference Value
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
EMC
Degree of protection
Weight (see note)
Battery life
Item
Item
7 years min. with continuous input at 25°C
(lithium battery)
100 MΩ min. (at 500 VDC) between current-carrying
metal parts and exposed non-current-carrying metal
parts, and between the backlight power supply and
count input terminals/reset terminals for backlight
models
1,000 VAC, 50/60 Hz for 1 min between current-car-
rying metal parts and exposed non-current-carrying
metal parts and between the backlight power supply
and count input terminals/reset terminals for back-
light models
4.5 kV between current-carrying terminal and exposed non-current-carrying metal parts
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±600 V (Between count input terminals)
±480 V (Between the backlight power supply termi-
nals for backlight models)
±8 kV (malfunction)
Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Malfunction: 200 m/s
Destruction: 300 m/s
(EMI)
Emission Enclosure:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
Front panel:
Terminal block: IP20
No-backlight model:Approx. 60 g
Backlight model:
Value
IP66, NEMA4 with waterproof packing
H7ER-NV@-@H
H7ER-NV@-@
Approx. 65 g
2
2
3 times each in 6 directions
3 times each in 6 directions
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
EN61326
EN55011 Group 1 class B
EN61326
EN61000-4-2: 4 kV contact discharge (level 2)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
EN61000-4-4: 2 kV power line (level 3)
8 kV air discharge (level 3)
2 kV I/O signal line (level 4)
100 MΩ min. (at 500 VDC) between current-carrying
metal parts and exposed non-current-carrying metal
parts
1,000 VAC, 50/60 Hz for 1 min between current-car-
rying metal parts and exposed non-current-carrying
metal parts
±500 V (Between count input terminals)
Note