B856-511 Veeder-Root, B856-511 Datasheet - Page 2

no-image

B856-511

Manufacturer Part Number
B856-511
Description
Timer; Multi-Function; SPDT; Cur-Rtg 5A; Ctrl-V 24-240/24AC/DC; 11 Pin
Manufacturer
Veeder-Root
Datasheet

Specifications of B856-511

Contact Form
SPDT
Current, Rating
5 A
Display Type
LCD
Function
Timing
Mounting Type
Panel
Number Of Pins
11
Power, Rating
50 VA
Relay Type
Electro Mechanical
Standards
UL, cUL
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Timer Type
Multi-Function
Voltage, Control
240⁄24 VAC⁄VDC
Lead Free Status / Rohs Status
RoHS Exempt Product
OPERATING MODES
On-Delay
Timing begins on the leading
edge of the start input. The
output will activate at the
completion of the preset time
(T) and will remain active until
the reset signal is applied or
power is interrupted.* For B856-
511, the instantaneous output will
activate upon the start signal and
will remain active until the reset
signal is applied or power is
interrupted.*
Off-Delay
The output is activated at the
leading edge of the start signal.
Timing begins on the trailing edge.
The output will remain active until
the preset time (T) has elapsed or
power is interrupted.* Reapplying
the start signal before T has
elapsed will reset the time value.
The reset input is not used.
Interval 1
On the leading of the start input,
the output is activated and timing
begins. The output will remain
active until the preset time (T) has
elapsed or power is interrupted.*
Removal of the start signal will
also cause the ouput to be
deactivated and the time value
reset. The reset input is not used.
Interval 2
On the leading of the start input,
the output is activated and timing
begins. The output will remain
active until the preset time (T) has
elapsed or power is interrupted.*
The reset input is not used.
Reapplying the start signal has no
effect unless the cycle has
completed.
Repeat Cycle
Timing begins on the leading edge
of the start input. A cycle is
initiated where the output will be
OFF for the preset time (T), then
ON for the preset time. This cycle
will continue until a reset signal
is applied or power is interrupted.*
The unit can also be programmed
for the timing sequence to begin
with an ON cycle.
Delay/Interval
The delay cycle begins upon
application of the start signal. The
output will activate at the completion
of the preset time (T1). Upon
activation of the output, the Interval
cycle will begin. The output will be
deactivated at the end of the Interval
time (T2). T1 is the primary preset
value. T2 is settable from 0.1 to
999.9 seconds. The timing
sequence and output can also be
reset through the reset input or
interruption of power.*
Power
Start
Output
Reset
Instant.
Output
Power
Start
Power
Start
Output
Power
Start
Output
Start
Output
Output
Reset
Power
Power
Start
Output
Reset
* The Power Reset parameter can be set so that a
timing sequence will not be reset upon power
interruption but instead continue on when power is
restored.
T
T
T
Repeat Cycle
T
T
T
T
1
T
T
2
T
T
T
ORDERING INFORMATION
48mm
Description
Multi-Function (11 Pin) Timer
As Above w/Instant Contacts
Multi-Function (8 Pin) Timer
*For Drop-In Replacement of LX260 DC Version, Order B856-502
B856-500 & -511:
B856-501:
Dimensions:
Connections
Start
11 Pin Socket
11 Pin Socket - Outward
8 Pin Socket
8 Pin Socket - Outward
instantaneous contacts
B856-500 & -511
For the -511 version,
3
4
Pins 1, 3, 4 are the
2
Facing Terminals
Facing Terminals
EAGLE SIGNAL
5
1
Power
48mm
6
11
DANAHER INDUSTRIAL CONTROLS
Reset
7
10
8
9
Accessories
8mm
66mm
Reset
* 24–240 VAC
B856-501
3
2
24 VDC
Model
B856-500
B856-511
B856-501*
60SR3P06
PBT-03172
60SR2P06
PBT-03155
15mm
4
1
or
Power*
Start
5
8
6
7
+
5.07
T
O
T
A
Z
N
G
L
I
I
C
R
O
N
C
E
L
E
T
I
5
M
R
S
T
E
I

Related parts for B856-511