V600 Lascar Electronics, V600 Datasheet

no-image

V600

Manufacturer Part Number
V600
Description
Module, Voltmeter; Volt Meter Meter Type; 3-1/2 Digit LCD; 0.6 in.; 9 VDC
Manufacturer
Lascar Electronics
Type
Voltager
Datasheets

Specifications of V600

Accuracy
0.25%
Digit Height
0.37
Dimensions
2.36 in. L x 0.26 in. W x 1.5 in. H
Display Digit Height
0.60 in.
Display Type
LCD
Function
Voltage
Meter Type
Volt Meter
Number Of Digits
3-1/2
Temperature, Operating
0 to +50 °C
Voltage, Supply
9 VDC
Cut Out, Panel
2.44×1.26 "
Primary Type
Electronic
Range, Measurement
200 mVDC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
V600-H11 0.5M
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
V600-H11 10M
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
V600-H11 2M
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
V600-H11 5M
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
V600-HA51 0.5M
Manufacturer:
OMRON
Quantity:
1 000
Part Number:
V600.26M
Manufacturer:
ST
0
Part Number:
V600ME02-LF
Manufacturer:
Z-COMM
Quantity:
20 000
V 600
LASCAR ELECTRONICS LTD.
MODULE HOUSE
WHITEPARISH
WILTSHIRE SP5 2SJ
UK
TEL: +44 (1794) 884567
FAX: +44 (1794) 884616
E-mail: sales@lascar.co.uk
PRODUCT DESCRIPTION
The V 600 features a 200mV d.c. measurement range with auto-zero and auto-polarity. Decimal points are user
selectable. The display features a low battery warning annunciator, which can be driven by external circuitry. The
module's low cost means it will suit most high volume applications.
FEATURES
TYPICAL APPLICATIONS
• High Volume, Low Cost Systems
• Power Supply Monitoring
• Panel-Mount Indication
ELECTRICAL SPECIFICATIONS
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed
60Vdc. The user must ensure that the incorporation of the panel meter into the user’s equipment conforms to the
relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and
Laboratory Use).
• Low Cost
• 15
• 200mV d.c. Full Scale Reading
• 1mA (typ) @ +9V d.c. Power Supply
• User Selectable
Specification
Accuracy (overall error) *
Linearity
Sample rate
Operating temperature range
Temperature stability
Supply voltage
Supply current
* To ensure maximum accuracy, re-calibrate periodically.
Auto-zero and Auto-polarity
Compatible with Industry-Standard Types
Supplied with Mounting Bezel
mm (0.6") Digit Height
Decimal Points
0-1000 reading
0-2000 reading
http://www.lascarelectronics.com
E-mail: us-sales@lascarelectronics.com
LASCAR ELECTRONICS INC.
4258 WEST 12th STREET
TEL: +1 (814) 835 0621
FAX: +1 (814) 838 8141
PA 16505
ERIE
USA
ORDERING INFORMATION
Standard Meter
Min.
7.0
0
Typ.
0.25
300
±3
±5
3
9
1
3½ Digit LCD Voltmeter Module
Max.
50
12
2
8th FLOOR, CHINA AEROSPACE CENTRE,
No.: 695 - Page 1 of 4
LASCAR ELECTRONICS (HK) LTD.
E- mail: saleshk@lascar.com.hk
% (±3 counts)
KWUN TONG, KOWLOON,
samples/sec
Stock Number
V 600
ppm/°C
counts
counts
V d.c.
Unit
mA
FAX: +852 2389 6535
°C
TEL: +852 2389 6502
143 HOI BUN ROAD,
HONG KONG
Page 2 of 4
Page 2 of 4

Related parts for V600

V600 Summary of contents

Page 1

... Max. Unit % (±3 counts) counts counts samples/sec 50 °C ppm/° d. LASCAR ELECTRONICS (HK) LTD. 8th FLOOR, CHINA AEROSPACE CENTRE, 143 HOI BUN ROAD, KWUN TONG, KOWLOON, HONG KONG TEL: +852 2389 6502 FAX: +852 2389 6535 E- mail: saleshk@lascar.com.hk Page Page No.: 695 - Page ...

Page 2

V 600 DIMENSIONS All dimensions in mm (inches) Panel thickness: 1.0 - 3.0 Panel cut-out: 62.0 - 32.0 PANEL FITTING Panel Meter Bezel 1 FUNCTIONAL BLOCK DIAGRAM VDD ROH Vref CAL COM RFH RFL INHI + A/D _ INLO VSS ...

Page 3

V 600 CIRCUIT DIAGRAM 15 VDD C1 27 68nF 28 R1 300k 220nF 13 31 INHI INLO 100nF 8 32 COM C4 34 100nF RFH 10 35 RFL 40 100k ...

Page 4

V 600 SCALING Two resistors Ra and Rb may be used to alter the full scale reading (FSR) of the meter - see table. The meter will have to be re- calibrated by adjusting the calibration potentiometer on the rear ...