Description
Meter, Indicator/Controller; LCD; 10 to 32 VDC; Panel; Rectangular; 88 Series
Manufacturer
Redington Counters, Inc.
Type
Counter/Rate Indicatorr
Datasheet

Specifications of 8800-0000

Accuracy
±0.01% %
Application
Batching, cut-off length, flow and level control
Brand/series
88 Series
Connection Type
Screw
Cut Out, Panel
2.63 to 2.605"×1.28 to 1.26"
Digit Height
0.5
Dimensions
4.46"L×2.96"W×1.62"H
Display Digit Height
0.35 "
Display Type
LCD
Function
Counter/Elapsed Time/Rate Indicator
Material, Casing
High Impact Black Plastic
Mounting Type
Panel
Number Of Digits
6
Primary Type
Electronic
Shape
Rectangular
Standards
UL Recognized, CE Marked
Temperature, Operating
-20 to +60 °C
Voltage, Supply
10 to 30 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Predetermining Timer:
Programmable Ranges:
Programmable Decimal Point:
Power Requirements:
Memory:
Sensor Power:
Front Panel Lockout:
Count/Timer Inputs (Input A & Input B):
Counter/Timer Operational Format:
Input Scaling:
Quadrature Counting:
Analog Input:
Input Impedence: 150K ohms, for 0 to 10VDC
Max. Count Rate: 40 KHz for single counter mode.
Rate Input Units: The rate input can be expressed in terms of scaled
86
Base unit:
Relay Module:
AC Power Supply: Model 200557-002S; +90VAC to +250 VAC 50/60 Hz
Counter A:
Counter B:
Rate Display:
Analog Input:
Time:
Model 88
Hours
Seconds
Hours, Minutes & Seconds
4 decimal point locations may be selected.
4 decimal point locations may be selected.
4 decimal point locations may be selected.
4 decimal point locations may be selected.
4 decimal point locations may be selected.
+10VDC TO +32VDC @ 50mA max.
Model 200557-001S; +10VDC to +32VDC @ 50mA,
max.
@ 6 VA max.
Nonvolatile EEPROM retains all program parameters
and values when power is removed. EEPROM pro-
vides 20 year data retention.
+12VDC @ 100mA, minimum (200557-002S Module)
Two front panel lockouts are available. In the program-
ming mode, the operator is prohibited from entering
new parameters. In the operating mode, the lockout
disallows manual reset of any displayed inputs.
Software selectable: switch contact or voltage input
Software Selectable: filter: no filter or 160 Hz 1
L.P.
Voltage Mode V
Voltage Mode V
Switch Mode V
Switch Mode V
Maximum Input voltage: 32.0VDC
Minimum Input voltage: -0.8VDC
Input A is used for all count functions
Input B is used for timer enable and all dual In-
put counter functions (i.e. ADD/ADD, ADD-SUB,
DIRECTIONAL COUNT, QUADRATURE, and DUAL
COUNT).
A & B Counters and analog input, (-9.9999 to
99.9999). The 8802 and 8812 units have an option for
prescaling the A & B counters from -9.9999 x 10
99.9999 x 10
Software selectable X1, 2, 4
0 to 10VDC or 4 to 20 mA
Resolution: 4 digit
100 ohms, for 4 to 20 mA
20 KHz for dual count modes
counts per minute (rP) or scaled counts per second
(Hz) of counter A. The 8802 and 8812 units can ex-
press rates in terms of scaled counts per minute (rP)
or scaled counts per hour of counter A.
-3
IH
IL
IH
IL
: 0.8VDC, max.
: 2.4 VDC, min. or open circuit
: 0.8VDC, max. or open circuit
: 2.4VDC, min.
Electronic
st
order
-3
to
Rate Indicator Accuracy:
Minimum Input Frequency:
Maxium Input
Frequency:
Reset Functions:
Reset-to-Zero:
Reset-to-Preset:
Resets:
Outputs:
Relay Module:
Relay Life Expectancy:
Programmable Timed Outputs:
Elapsed Timer Accuracy: ± 0.01% @T=25°C
Analog Output:
RS232/RS485/RS422 Serial Communications: (Optional)
Certifications & Compliances:
Environmental Conditions:
Electrical Connection: Wire clamping screw terminals
Construction:
Panel Thickness: 0.05” to 0.20” [1.3 to 5.1mm]
Weight:
LCD Programmable Indicator/Controller
Baud Rate:
Data Length/Parity/Stop Bits:
RS485 Address:
Transceiver Loading:
Operating Temperature:
Storage Temperature:
Altitude:
Operating & Storage Humidity: to 95% (non-condensing) from -4°F
Accuracy:
Resolution:
0 TO 10VDC OR 4 TO 20mA
0.25% of full scale @ T = 25°C
14 bits
UL, cUL- Recognized Component, file # E 195514
CE-Compliant to EN 61326: 1998 for industrial equip-
ment
High impact black plastic case with “Clip” type mount.
Front panel meets NEMA 4X/IP65 requirements for
indoors use, when properly installed. Oversized front
panel flange insures proper sealing of panel cutouts.
Gaskets for front panel are provided.
Less than 3 oz. (85g)
100,000 cycles min. @ max. rated load.
Both control outputs can be timed.
1 pulse in 10 seconds
40 K HZ
(Automatic & manual)
Can be programmed so that the output activates
when counter equals the preset value, counter
returns to zero when reset.
Can be programmed so that the output activates
when counter equals zero, Counter returns to Pre-
set value when reset.
Automatic or manual.
Base unit; Solid-state NPN: (2) Open collector:
I
Model 200557-001S; 2 form “C” relays rated @ 5
amps 250 VAC, 30VDC(resistive load) 1/10
@120VAC (inductive load)
±0.01%, References Time Base @T=25°C
SNK
=100mA @V
Selectable 2400, 4800, 9600, or 19.2K
8n1
Programmable from 0 to 99.
RS232/RS485/RS422- up to 16 loads
-4°F to +140°F [-20°C to +60°C]
-40°F to +185°F [-40°C to +85°C]
Up to 6561Ft. (2000 Meters)
to +140°F [-20°C to +60°C]
OL
=1.1VDC V
OH
=40VDC
th
HP

Related parts for 8800-0000