7022OE TE Connectivity, 7022OE Datasheet - Page 3

no-image

7022OE

Manufacturer Part Number
7022OE
Description
Relay; Electropneumatic; Timing; Off Delay; DPDT; Ctrl-V 24DC; 20-200 sec.
Manufacturer
TE Connectivity
Datasheet

Specifications of 7022OE

Brand/series
7000 Series
Contact Form
DPDT
Current, Rating
5, 10, 15 A
Dimensions
3.25 in. L x 2.57 in. (Max.) W x 6.23 in. (Max.) H
Function
Timing
Mounting Type
Panel
Relay Type
Electropneumatic
Repeat Accuracy
± 5%
Resistance, Insulation
500 Megohms @ 500 VDC
Standards
UL, CSA, CE
Temperature, Operating, Range
-30 to +75 °C
Termination
Screw
Timer Type
Off Delay
Timing Range
20 to 200 sec.
Tyco Part Number
1-1423164-1
Voltage, Control
24 VDC
Voltage, Rating
240, 600⁄30 VAC⁄VDC
Weight
2 lbs. 4 Oz.
Many Enclosure Options
Explosion Proof, Dust Tight, Water Tight, Hermetically Sealed, NEMA 1
Numerous Mounting Options
Surface-Mount, Panel-Mount, Octal Plug-In Mounting
Options And Accessories
Quick-Connect Terminals, Dial Stops and Transient Protections Module
Supply Voltage
24 VDC
Contact Rating
10 A at 240 VAC
Termination Style
Screw
Lead Free Status / Rohs Status
No
1250
Timing Specifications
Operating Modes:
Timing Adjustment: Timing is set by simply turning the dial to the desired
time value. In the zone of approximately 25° separating the high and low
end of timing ranges A,D,E, and K, instantaneous operation (no time delay)
will occur. All other ranges produce an infinite time delay when the dial is
set in this zone.
upper end of the time ranges in these models may be twice the values
shown.
Linear Timing Ranges:
Repeat Accuracy:
For delays of 200 seconds or less:
For delays greater than 200 seconds:
* The first time delay afforded by Model 7012 with H (3 to 30 min.) and I (6
Reset Time: 50 msec. (except model 7032)
Relay Release Time: 50 msec. for on-delay models (7012/7014)
Relay Operate Time: 50 msec. for off-delay models (7022/7024)
Operating Voltage Coil Data (for DPDT)
Coil
Part # Letter
7000
AC
7010
DC
*Four pole Models: Operational voltage range 90% to 110% for AC units;
85% to 110% for DC units.
See next column for more coil data.
Dimensions are shown for
reference purposes only.
Model 7012/7014: On-delay (delay on pick-up).
Model 7022/7024: Off-delay (delay on drop-out).
Model 7032: On-delay, off-delay (double head).
to 60 min.) time ranges or Model 7014 with H time range will be approx.
15% longer than subsequent delays due to coil temperature rise.
Models 7014 and 7032 are available with letter-calibrated dials only. The
Code
M
W
A
D
G
H
N
O
Q
U
B
C
E
F
J
K
L
P
R
S
T
V
Y
Z
X
I
Voltage
Rated
120
240
480
550
208
125
250
550
220
24
12
28
48
24
12
60
16
32
96
6
6
Code
A
B
C
D
E
F
H
I
J
K
(All values shown are at nominal voltage and 25°C unless otherwise specified).
Operating*
Voltage
Range
@ 60Hz
102-132
204-264
408-528
468-605
20.5-26.5
10.2-13.2
5.1-6.6
178-229
Dual Voltage Coil
(Combines A&B)
Special AC Coils
(L1, L2, etc.)
22.4-30.8
38.4-52.8
19.2-26.4
100-137.5
9.6-13.2
48-66
200-275
440-605
12.8-17.6
25.8-35.2
76.8-105.6
4.8-6.6
176-242
Special DC Coils
(X1, X2, etc.)
Models 7012,
.1 to 1 Sec.
.5 to 5 Sec.
1.5 to 15 Sec
5 to 50 Sec.
20 to 200 Sec.
1 to 10 Min.
3 to 30 Min.
6 to 60 Min.
3 to 120 Cyc.
1 to 300 Sec.
7022, 7024
7012*, 7022, 7024:
7014*:
7032:
7012*, 7022, 7014*, 7024: +10%
7032:
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Voltage
Rated
110
220
127
240
Models 7014,
.2 to 2 Sec.
.7 to 7 Sec.
2 to 20 Sec.
10 to 100 Sec.
30 to 300 Sec.
1.5 to 15 Min.
3 to 30 Min.
Not Avail.
Not Avail.
Not Avail.
7032
Operating
Issued 3-03 (PDF Rev. 10-07)
93.5-121
Voltage
187-242
108-140
204-264
@50Hz
Range
+5%
+10%
+15%
+15%
Catalog 1308242
Minimum operating voltages are based on vertically mounted 7012 units.
7012 horizontally mounted or 7022 vertically or horizontally mounted units
will operate satisfactorily at minimum voltages approximately 5% lower than
those listed.
AC units drop out at approximately 50% of rated voltage. DC units drop out
at approximately 10% of rated voltage.
All units may be operated on intermittent duty cycles at voltages 10% above
the listed maximums (intermittent duty - maximum 50% duty cycle and 30
minutes "on" time.)
Surge/Transient Protection Option Characteristics (DC Timers Only)
Surge Life
Applied 100,000 times continuously with the interval of 10 seconds at room
temperature. Below 68 VAC: 12A; Above 68 VAC: 35A
Temperature Range
Operating: -22°F to +167°F (-30°C to + 75°C)
Storage:
Output/Life Contact Ratings: Contact Capacity in Amps (Resistive Load)
Contact
Voltage
30 VDC
110 VDC
120 V 60Hz
240 V 60Hz
480 V 60Hz
10 Amps Resistive, 240 VAC
1/4 Horsepower, 120 VAC/240VAC (per pole)
15 Amps 30 VDC (per pole)
5 Amps, General Purpose, 600VAC (per pole)
Dielectric: Withstands 1500 volts RMS 60Hz between terminals and
ground. 1,000 volts RMS 60 Hz between non-connected terminals. For
dielectric specification on hermetically sealed models consult factory.
Insulation Resistance: 500 Megohms with 500VDC applied.
Temperature Range: Operating: -20°F to +165°F (-29°C to 74°C)
Temperature Variation: Using a fixed time delay which was set and
measured when the ambient temperature was 77°F (25°C), the maximum
observed shift in the average of three consecutive time delays was -20% at
Mounting/Terminals: Normal mounting of the basic unit is in a vertical
position, from the back of the panel. A front mounting bracket is also
supplied with each basic unit, for installation from the front of the panel.
All units are calibrated for vertical operation. Basic models (7012, 7022)
may also be horizontally mounted, and will be adjusted accordingly when
Accessory Y1 is specified in your order.
on the front of the unit, with permanent schematic markings. Barrier
isolation is designed to accommodate spade or ring tongue terminals, with
spacing to meet all industrial control specifications.
panelmount kit that includes all necessary hardware and faceplate. This
offers the convenience of "out-front" adjustment, with large calibrated dial
skirt knob. The faceplate and knob blend with advanced equipment and
console designs, while the body of the unit and its wiring are protected
behind the panel.
to meet unusual installation requirements. Contact factory for details.
Power Consumption: Approximately 8 watts power at rated voltage .
Approximate Weights:
Models
Weight may vary slightly with coil voltage.
Specifications and availability
subject to change.
-20°F (-29°C) and +20% at 165°F (74°C).
Nominal (DC)
12 V
24 V
28 V
32 V
48 V
60 V
96 V
110 V
125 V
220 V
250 V
Standard screw terminals (8-32 truss head screws supplied) are located
The basic Series 7000 may also be panel mounted with the addition of a
Other mounting options include plug-in styles and special configurations
Coil Voltage
-40°F to +167°F (-40°C to +75°C)
7012, 7022 . . . . . . . 2 lbs. 4 ozs.
7014, 7024 . . . . . . . 2 lbs. 10 ozs.
7032 . . . . . . . . . . . . 3 lbs. 5 ozs.
Min. 100,000
Operations
15.0
1.0
20.0
20.0
12.0
Storage:
Max Excess
Energy Capacity (Joule)
0.4 J
1.8 J
1.8 J
2.5 J
3.57 J
6 J
10 J
10 J
10 J
17 J
17 J
Min. 1,000,000
Operations
7.0
0.5
15.0
15.0
10.0
-67°F to +165°F (-55°C to 74°C)
Max De-energization
Transient Voltage
48 V
93 V
93 V
135 V
145 V
250 V
340 V
340 V
340 V
366 V
366 V
AGASTAT

Related parts for 7022OE